Refine Your Search

Search Results

Viewing 1 to 13 of 13
Technical Paper

Rear Seat Occupant Safety: An Investigation of a Progressive Force-Limiting, Pretensioning 3-Point Belt System Using Adult PMHS in Frontal Sled Tests

2009-11-02
2009-22-0002
Rear seat adult occupant protection is receiving increased attention from the automotive safety community. Recent anthropomorphic test device (ATD) studies have suggested that it may be possible to improve kinematics and reduce injuries to rear seat occupants in frontal collisions by incorporating shoulder-belt force-limiting and pretensioning (FL+PT) technologies into rear seat 3-point belt restraints. This study seeks to further investigate the feasibility and potential kinematic benefits of a FL+PT rear seat, 3-point belt restraint system in a series of 48 kmh frontal impact sled tests (20 g, 80 ms sled acceleration pulse) performed with post mortem human surrogates (PMHS). Three PMHS were tested with a 3-point belt restraint with a progressive (two-stage) force limiting and pretensioning retractor in a sled buck representing the rear seat occupant environment of a 2004 mid-sized sedan.
Technical Paper

Comparison of PMHS, WorldSID, and THOR-NT Responses in Simulated Far Side Impact

2007-10-29
2012-01-1537
Injury to the far side occupant has been demonstrated as a significant portion of the total trauma in side impacts. The objective of the study was to determine the response of PMHS in far side impact configurations, with and without generic countermeasures, and compare responses to the WorldSID and THOR dummies. A far side impact buck was designed for a sled test system that included a center console and three-point belt system. The buck allowed for additional options of generic countermeasures including shoulder or thorax plates or an inboard shoulder belt. The entire buck could be mounted on the sled in either a 90-degree (3-o'clock PDOF) or a 60-degree (2-o'clock PDOF) orientation. A total of 18 tests on six PMHS were done to characterize the far side impact environment at both low (11 km/h) and high (30 km/h) velocities. WorldSID and THOR-NT tests were completed in the same configurations to conduct matched-pair comparisons.
Technical Paper

Comparison of PMHS, WorldSID, and THOR-NT Responses in Simulated Far Side Impact

2007-10-29
2007-22-0014
Injury to the far side occupant has been demonstrated as a significant portion of the total trauma in side impacts. The objective of the study was to determine the response of PMHS in far side impact configurations, with and without generic countermeasures, and compare responses to the WorldSID and THOR dummies. A far side impact buck was designed for a sled test system that included a center console and three-point belt system. The buck allowed for additional options of generic countermeasures including shoulder or thorax plates or an inboard shoulder belt. The entire buck could be mounted on the sled in either a 90-degree (3-o'clock PDOF) or a 60-degree (2-o'clock PDOF) orientation. A total of 18 tests on six PMHS were done to characterize the far side impact environment at both low (11 km/h) and high (30 km/h) velocities. WorldSID and THOR-NT tests were completed in the same configurations to conduct matched-pair comparisons.
Technical Paper

Thoracic Response of Belted PMHS, the Hybrid III, and the THOR-NT Mid-Sized Male Surrogates in Low-Speed, Frontal Crashes

2006-11-06
2006-22-0009
Injury to the thorax is the predominant cause of fatalities in crash-involved automobile occupants over the age of 65, and many elderly-occupant automobile fatalities occur in crashes below compliance or consumer information test speeds. As the average age of the automotive population increases, thoracic injury prevention in lower severity crashes will play an increasingly important role in automobile safety. This study presents the results of a series of sled tests to investigate the thoracic deformation, kinematic, and injury responses of belted post-mortem human surrogates (PMHS, average age 44 years) and frontal anthropomorphic test devices (ATDs) in low-speed frontal crashes. Nine 29 km/h (three PMHS, three Hybrid III 50th% male ATD, three THOR-NT ATD) and three 38 km/h (one PMHS, two Hybrid III) frontal sled tests were performed to simulate an occupant seated in the right front passenger seat of a mid-sized sedan restrained with a standard (not force-limited) 3-point seatbelt.
Technical Paper

Biomechanical Response of the Pediatric Abdomen, Part 1: Development of an Experimental Model and Quantification of Structural Response to Dynamic Belt Loading

2006-11-06
2006-22-0001
The abdomen is the second most commonly injured region in children using adult seat belts, but engineers are limited in their efforts to design systems that mitigate these injuries since no current pediatric dummy has the capability to quantify injury risk from loading to the abdomen. This paper develops a porcine (sus scrofa domestica) model of the 6-year-old human's abdomen, and then defines the biomechanical response of this abdominal model. First, a detailed abdominal necropsy study was undertaken, which involved collecting a series of anthropometric measurements and organ masses on 25 swine, ranging in age from 14 to 429 days (4-101 kg mass). These were then compared to the corresponding human quantities to identify the best porcine representation of a 6-year-old human's abdomen. This was determined to be a pig of age 77 days, and whole-body mass of 21.4 kg.
Technical Paper

Whole-body Kinematic and Dynamic Response of Restrained PMHS in Frontal Sled Tests

2006-11-06
2006-22-0013
The literature contains a wide range of response data describing the biomechanics of isolated body regions. Current data for the validation of frontal anthropomorphic test devices and human body computational models lack, however, a detailed description of the whole-body response to loading with contemporary restraints in automobile crashes.
Technical Paper

Elimination of Thoracic Muscle Tensing Effects for Frontal Crash Dummies

2005-04-11
2005-01-0307
Current crash dummy biofidelity standards include the estimated effects of tensing the muscles of the thorax. This study reviewed the decision to incorporate muscle tensing by examining relevant past studies and by using an existing mathematical model of thoracic impacts. The study finds evidence that muscle tensing effects are less pronounced than implied by the biofidelity standard response corridors, that the response corridors were improperly modified to include tensing effects, and that tensing of other body regions, such as extremity bracing, may have a much greater effect on the response and injury potential than tensing of only the thoracic musculature. Based on these findings, it is recommended that muscle tensing should be eliminated from thoracic biofidelity requirements until there is sufficient information regarding multi-region muscle tensing response and the capability to incorporate this new data into a crash dummy.
Technical Paper

The Utility of Hybrid III and THOR Chest Deflection for Discriminating Between Standard and Force-Limiting Belt Systems

2003-10-27
2003-22-0013
Recent field data studies have shown that force-limiting belt systems reduce the occurrence of thoracic injuries in frontal crashes relative to standard (not force-limiting) belt systems. Laboratory cadaver tests have also shown reductions in trauma, as well as in chest deflection, associated with a force-limiting belt. On the other hand, tests using anthropomorphic test devices (ATDs) have shown trends indicating increased, decreased, or unchanged chest deflection. This paper attempts to resolve previous experimental studies by comparing the anterior-posterior and lateral chest deflections measured by the THOR and Hybrid III (H-III) dummies over a range of experimental conditions. The analysis involves nineteen 48-km/h and 57-km/h sled tests utilizing force-limiting and standard seat belt systems, both with an air bag. Tests on both the driver side and the passenger side are considered.
Technical Paper

Comparison of Belted Hybrid III, THOR, and Cadaver Thoracic Responses in Oblique Frontal and Full Frontal Sled Tests

2003-03-03
2003-01-0160
This paper compares restrained Hybrid III and THOR thoracic kinematics and cadaver injury outcome in 30° oblique frontal and in full frontal sled tests. Peak shoulder belt tension, the primary source of chest loading, changed by less than four percent and peak chest resultant acceleration changed by less than 10% over the 30° range tested. Thoracic kinematics were likewise insensitive to the direction of the collision vector, though they were markedly different between the two dummies. Mid-sternal Hybrid III chest deflection, measured by the standard sternal potentiometer and by supplemental internal string potentiometers, was slightly lower (∼10%) in the oblique tests, but the oblique tests produced a negligible increase in lateral movement of the sternum. In an attempt to understand the biofidelity of these dummy responses, a series of 30-km/h human cadaver tests having several collision vectors (0°, 15°, 30°, 45°) was analyzed.
Technical Paper

Response and vulnerability of the ankle joint in simulated footwell intrusion experiments~A study with cadavers and dummies

2001-06-04
2001-06-0212
The prevention of lower extremity injuries to front seat car occupants is a priority because of their potential to cause long-term impairment and disability. To determine the types and mechanisms of lower extremity injuries in frontal collisions, studies under controlled test conditions are needed. Sled tests using belt-restrained cadavers and dummies were conducted, in which footwell intrusion was simulated via a plane surface or simulated brake pedal. Human cadavers in the age range from 30 to 62 years and Hybrid III dummies were used. The footwell intrusion had both translational (135 mm) and rotational (30 degrees) components. Maximum footwell intrusion forces and accelerations were measured. The lower legs were instrumented with accelerometers and a ""six axis'' force-moment transducer was mounted in the mid shaft of the left tibia.
Technical Paper

Response and Vulnerability of the Upper Arm Through Side Air Bag Deployment

1997-11-12
973323
The number of passenger cars equipped with side air bags is steadily increasing. With the aim of investigating the mechanical responses and the injuries of the arm under the influence of a side air bag, tests in probably higher injury risk configurations with dummies and cadavers were performed. The air bag was installed at the outer side of the seat back, with the subject seated in the driver or front passenger seat of a passenger car. During the inflation of the air bag, the left or right forearm of the subject was positioned on the arm rest while the upper arm made contact with the seat back edge. The volume of the thorax air bag was 15 litres and for the thorax-head air bag 28 litres. The dummy was instrumented at the thorax c.g. shoulder, elbow and wrist with triaxial accelerometers. In the cadaver, triaxial accelerations in three orthogonal directions were measured at the upper and the lower humerus, the upper radius and the lower radius and the first thoracic vertebrae.
Technical Paper

The Biofidelity of EUROSID 1 and BIOSID

1992-11-01
922518
A current priority in Europe and the USA is the development of improved side collision dummies. This report presents the results of sled tests with three test subject types: cadavers (PMHS), EUROSID 1 and BIOSID. Twenty one (21) cadaver tests were performed and 9 dummy tests a piece. The left side of the test subjects were impacted under one of two different test conditions: 24 km/h rigid wall and 32 km/h padded wall. The cadavers were instrumented with a 12 thoracic, and triaxial pelvic accelerometer arrays. Thoracic deformation was calculated from rib accelerations. The dummies were instrumented in their standard formats, which included the ability to measure coronal plane thoracic deformation. For all test subject types and measurement locations the 3ms. acceleration standard deviations were low. Mean 3ms. accelerations showed no consistent relationship in magnitude between subject types. The measured dummy rib deformations were compared to the calculated cadaver deformations.
Technical Paper

Comparison Between Frontal Impact Tests with Cadavers and Dummies in a Simulated True Car Restrained Environment

1982-02-01
821170
A test series of 12 fresh cadavers and 5 Part 572 dummies is reported. The test configuration is frontal impact sled simulation at 30 mph and aims to simulate the restraint environment of a Volvo 240 car. The test occupants are restrained in a 3-point safety belt. The instrumentation of the surrogates involves mainly 12-accelerometers in chest, 9-accelerometers in head and 3-accelerometers in pelvis. Measured values are given and discussed together with the medical findings from the cadaver tests. The occurence of submarining with cadavers and dummies is reported. A comparison is also made with earlier work where both field accidents and sled simulatations of similar violence have been reported. It is concluded that there exist differences in kinematics between the dummy and the cadaver, although peak chest acceleration is similar in both conditions. The lap belt slides over the iliac crest more frequently in the cadaver tests than in the dummy tests.