Refine Your Search

Topic

Search Results

Standard

Performance Requirements for SAE J844 Nonmetallic Air Brake Tubing and SAE J246 Compression Fitting Assemblies Used in Vehicular Air Brake Systems

2021-05-06
CURRENT
J1131_202105
This SAE Standard is intended to establish uniform performance criteria and methods of testing compression tube fittings with SAE J844 air brake tubing as used in vehicular air brake systems. This document also establishes minimum qualifications for tensile and pressure capabilities, vibration durability under cyclic temperatures, serviceability, and fitting compatibility requirements. The specific tests and performance criteria applicable to the tubing are set forth in SAE J844. NOTE: The test values contained in this performance standard are for test purposes only. For environmental and usage limitations, refer to SAE J844. For fittings, a type of fitting for use with SAE J844 nonmetallic tubing is included in SAE J246; however, it is not intended to restrict or preclude the use of other designs of fittings that comply with this document.
Standard

Refrigeration Tube Fittings—General Specifications

2019-12-19
CURRENT
J513_201912
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 1 to 15. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1 to 15 with respect to all unspecified details.
Standard

Performance Requirements for SAE J844 Nonmetallic Air Brake Tubing and Push to Connect Fitting Assemblies Used in Vehicular Air Brake Systems

2019-02-21
HISTORICAL
J2494/3_201902
This SAE Standard is intended to establish uniform performance criteria and methods of testing push-to-connect tube fittings, with SAE J844 air brake tubing as used in vehicular air brake systems. The specific tests and performance criteria applicable to the tubing are set forth in SAE J844. The test values contained in this performance standard are for test purposes only. For environmental and usage limitations, refer to SAE J844.
Standard

Metric Nonmetallic Air Brake System Tubing1

2013-06-11
CURRENT
J1394_201306
This SAE Standard covers the minimum requirements for metric sizes of nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system that operates below -40 °C (-40 °F), above +93 °C (+200 °F), above a maximum working gage pressure of 1.0 MPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections that maintain a basically fixed relationship between components during vehicle operation.
Standard

Performance Requirements for SAE J844 Non-Metallic Air Brake Tubing and Push to Connect Fitting Assemblies Used in Vehicular Air Brake Systems

2007-08-14
HISTORICAL
J2494/3_200708
This SAE Standard is intended to establish uniform performance criteria and methods of testing push to connect tube fittings, with SAE J844 air brake tubing as used in vehicular air brake systems. The specific tests and performance criteria applicable to the tubing are set forth in SAE J844. The test values contained in this performance standard are for test purposes only. For environmental and usage limitations, see SAE J844.
Standard

Nonmetallic Air Brake System Tubing

2004-11-04
HISTORICAL
J844_200411
This SAE Standard covers the minimum requirements for nonmetallic tubing as manufactured for use in air brake systems. Non-reinforced products are designated type A and reinforced products, type B. It is not intended to cover tubing for any portion of the system which operates below −40 °C, above +93 °C, above a maximum working gage pressure of 1.0 MPa, or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections, which maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this document, SAE J1131, and SAE J2494-3 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections which are used in the construction of such assemblies2.
Standard

Metric Nonmetallic Air Brake System Tubing1

2004-06-30
HISTORICAL
J1394_200406
This SAE Standard covers the minimum requirements for metric sizes of nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system that operates below −40 °C (−40 °F), above +93 °C (+200 °F), above a maximum working gage pressure of 1.0 MPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections that maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this standard and SAE J1131 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections, which are used in the construction of such assemblies.2
Standard

Metric Nonmetallic Air Brake System Tubing1

2000-04-01
HISTORICAL
J1394_200004
This SAE Standard covers the minimum requirements for metric sizes of nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system that operates below −40 °C (−40 °F), above +93 °C (+200 °F), above a maximum working gage pressure of 1.0 MPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections that maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this standard and SAE J1131 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections, which are used in the construction of such assemblies.2
Standard

Refrigeration Tube Fittings—General Specifications

1999-01-05
HISTORICAL
J513_199901
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 1 to 15. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1 to 15 with respect to all unspecified details.
Standard

Nonmetallic Air Brake System Tubing

1998-06-01
HISTORICAL
J844_199806
This SAE Standard covers the minimum requirements for nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system which operates below −40 °C (–40 °F), above +93°C (+200 °F), above a maximum working gage pressure of 1030 kPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections which maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this document and SAE J1131 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections which are used in the construction of such assemblies2.
Standard

NONMETALLIC AIR BRAKE SYSTEM TUBING

1997-05-01
HISTORICAL
J844_199705
This SAE Standard covers the minimum requirements for nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system which operates below −40 °C (−40 °F), above +93 °C (+200 °F), above a maximum working gage pressure of 1030 kPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections which maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this document and SAE J1131 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections which are used in the construction of such assemblies2.
Standard

REFRIGERATION TUBE FITTINGS—GENERAL SPECIFICATIONS

1996-06-01
HISTORICAL
J513_199606
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 1 to 15. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1 to 15 with respect to all unspecified details.
Standard

NONMETALLIC AIR BRAKE SYSTEM TUBING

1994-10-01
HISTORICAL
J844_199410
This SAE Standard covers the minimum requirements for nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system which operates below −40 °C (−40 °F), above +93 °C (+200 °F), above a maximum working gage pressure of 1030 kPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections which maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this document and SAE J1131 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections which are used in the construction of such assemblies2.
Standard

AUTOMOTIVE PIPE, FILLER, AND DRAIN PLUGS

1994-06-01
HISTORICAL
J531_199406
This SAE Standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figures 1 to 6 and Tables 1 to 4) commonly used in automotive and related industrial applications.
Standard

AUTOMOTIVE PIPE FITTINGS

1994-05-01
HISTORICAL
J530_199405
This SAE Standard includes complete general and dimensional specifications for those types of pipe fittings commonly used in the automotive and other mass production industries where the use of lubricants or sealers is objectionable. The automotive pipe fittings shown in Figures 1 to 17 and Tables 1 to 6 are intended for general automotive and similar applications involving low or medium pressures or in conjunction with automotive tube fittings in piping systems.
Standard

REFRIGERATION TUBE FITTINGS—GENERAL SPECIFICATIONS

1994-05-01
HISTORICAL
J513_199405
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 1 to 16. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1 to 16 with respect to all unspecified details.
Standard

AUTOMOTIVE PIPE FITTINGS

1993-06-01
HISTORICAL
J530_199306
This SAE Standard includes complete general and dimensional specifications for those types of pipe fittings commonly used in the automotive and other mass production industries where the use of lubricants or sealers is objectionable. The automotive pipe fittings shown in Figures 1 to 17 and Tables 1 to 6 are intended for general automotive and similar applications involving low or medium pressures or in conjunction with automotive tube fittings in piping systems.
Standard

AUTOMOTIVE PIPE, FILLER, AND DRAIN PLUGS

1993-06-01
HISTORICAL
J531_199306
This SAE Standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figures 1 to 6 and Tables 1 to 4) commonly used in automotive and related industrial applications.
Standard

REFRIGERATION TUBE FITTINGS—GENERAL SPECIFICATIONS

1993-06-01
HISTORICAL
J513_199306
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 1 to 16. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1 to 16 with respect to all unspecified details.
X