Refine Your Search

Topic

Search Results

Standard

Oxygen System Fill/Check Valve

2023-01-26
CURRENT
AS1225A
This SAE Aerospace Standard (AS) defines minimum standards of design, construction, and performance for two types of permanently installed, high pressure 12,800 kPa (1850 psig) and 13,800 kPa (2000 psig) oxygen system cylinder fill valves used in commercial aircraft. Refer to Purchaser's Specification for Requirements which are beyond the scope or level of detail provided in this document. One valve has an adjustable pressure sensitive closing valve to automatically control the final pressure for a correct amount of oxygen in the system. The second valve incorporates an automatic shutoff feature designed to limit system overpressurization in the event maintenance personnel do not stop system filling at the correct pressure. The intent of the fill valves is to control the rate of fill to limit the rise in temperature caused by compression heating to acceptable values, prevent oxygen back flow and prevent the ingestion of foreign matter that could cause contamination of the system.
Standard

Continuous Flow Oxygen Systems

2023-01-26
CURRENT
AIR825/8
This SAE Aerospace Information Report (AIR) provides general information on Continuous Flow Oxygen Systems which are available, principle functions of those systems and technical approaches to be taken into account during design and realization of systems. However, particular performance specifications and detailed information of manufacturing, testing and integration of such systems is beyond the scope of this document.
Standard

Demand Oxygen Systems

2023-01-26
CURRENT
AIR825/9
This SAE Aerospace Information Report (AIR) describes the general operating principles of demand oxygen equipment, including variant types such as diluter-demand and pressure breathing equipment. The sources of oxygen supply that can be used in connection with a demand oxygen mask are in principle the same as those used for other oxygen dispensing devices. Except for mention of a few features specifically related to demand equipment, this document does not discuss oxygen sources in detail and the reader is advised to consult other applicable documents that describe the operation of oxygen sources for additional information.
Standard

Packaging and Transportation of Oxygen Equipment

2023-01-26
CURRENT
AIR5742A
The scope of this document is related to the particular needs of oxygen equipment with regards to packaging and transportation. The document provides guidance for handling chemical, gaseous and liquid oxygen equipment. It summarizes national and international regulations to be taken into account for transportation on land, sea and air and provides information on classification of hazardous material. The aim of this document is to summarize information on packaging and transportation of oxygen equipment. Statements and references to regulations cited herein are for information only and should not be considered as interpretation of a law. Processes to maintain cleanliness of components and subassemblies during processing and assembly or storage of work-in-progress are outside the scope of this document. Guidance on this can be obtained from ARP1176.
Standard

FAR - Regulatory Requirements Covering the Use of Breathing Oxygen in Aircraft

2022-06-27
CURRENT
AIR1389C
This report presents, paraphrased in tabular format, an overview of the Federal Aviation Regulations (FAR) for aircraft oxygen systems. It is intended as a ready reference for those considering the use of oxygen in aircraft and those wishing to familiarize themselves with the systems requirements for existing aircraft. This document is not intended to replace the oxygen related FAR but rather to index them in some order. For detailed information, the user is referred to the current issue of the relevant FAR paragraph referenced in this report.
Standard

Gaseous Oxygen and Oxygen Equipment, Introductory

2022-05-02
CURRENT
AIR825/3A
This SAE Aerospace Information Report provides a general discussion on gaseous breathing oxygen and oxygen equipment for use on commercial aircraft. Other types of oxygen systems are mentioned to assist in this discussion. For detailed information on systems other than gaseous, refer to the appropriate section of AIR825.
Standard

Introduction to Oxygen Equipment for Aircraft

2021-08-11
CURRENT
AIR825/1
The purpose of this document is to give the reader an overview of the document package which makes up AIR825, Introduction to Oxygen Equipment for Aircraft, and a basic overview (see Section 4) of the operational concerns driven by human physiology during altitude exposure.
Standard

Basic Aircraft Oxygen Systems Design

2021-08-11
CURRENT
AIR825/14
This slash document collects general reference material related to gaseous oxygen system flow requirements and sizing calculations. This document will assist oxygen system equipment designers and operators to establish systems and equipment requirements. The document consists of charts, tables, system schematics, system requirements, and sample calculations for system sizing.
Standard

Testing of Oxygen Equipment

2021-08-11
CURRENT
ARP1398A
This ARP delineates requirements for system cleanliness, test gas supply system, test stand design, environmental chamber definition, instrumentation, dynamic test equipment and testing procedures.
Standard

Passenger Oxygen Mask

2021-08-11
CURRENT
AS8025A
This standard covers oronasal type masks which use a continuous flow oxygen supply. Each such mask comprises a facepiece with valves as required, a mask suspension device, a reservoir, or rebreather bag (when used), a length of tubing for connection to the oxygen supply source, and a means for allowing the crew to determine if oxygen is being delivered to the mask. The assembly shall be capable of being stowed suitably to meet the requirements of its intended use.
Standard

Minimum Standard for Portable Gaseous, Oxygen Equipment

2021-08-11
CURRENT
AS1046C
This standard is intended to apply to portable compressed gaseous oxygen equipment. When properly configured, this equipment is used either for the administration of supplemental oxygen, first aid oxygen or smoke protection to one or more occupants of either private or commercial transport aircraft. This standard is applicable to the following types of portable oxygen equipment: a Continuous flow 1 Pre-set 2 Adjustable 3 Automatic b Demand flow 1 Straight-demand 2 Diluter-demand 3 Pressure-demand c Combination continuous flow and demand flow.
Standard

Gaseous Oxygen and Oxygen Equipment, Introductory

2021-08-11
HISTORICAL
AIR825/3
This Aerospace Information Report provides a general discussion on gaseous breathing oxygen and oxygen equipment for use on commercial aircraft. Other types of oxygen systems are mentioned to assist in this discussion. For detailed information on systems other than gaseous, reference the appropriate section of AIR825.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2021-03-09
WIP
AS1219B
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Minimum Standard for Gaseous Oxygen Pressure Reducers

2020-05-27
CURRENT
AS1248B
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2020-02-28
CURRENT
AS1219A
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Crewmember Demand Oxygen Mask for Transport Category Aircraft

2019-08-14
CURRENT
AS8026B
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Continuous Flow Oxygen Regulator

2018-10-18
HISTORICAL
AS1197A
This standard covers regulators of the following types: Type I - Automatic Continuous Flow Type II - Adjustable Continuous Flow Type III - Pre-set Continuous Flow Class A - Cylinder Mounted Class B - Line Mounted Special - Composite Continuous Flow (Appendix)
Standard

Minimum Standard for Gaseous Oxygen Pressure Reducers

2017-11-07
HISTORICAL
AS1248A
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
Standard

Provisions of Medical Oxygen for Aircraft Occupants

2017-11-07
CURRENT
AIR6190
This document provides information on provisions for passengers with disabilities on board commercial aircraft. In this context the term "provision of medical oxygen" shall be understood as application of oxygen on board an aircraft not linked to (post) decompression in the sense of Airworthiness Requirements FAR/CS 25 and Operational Regulations of FAR 121/135. Information about available equipment and physiological treatment in clinical practice will be provided in this document. It covers the use of oxygen concentrators according to guidance of FAR Advisory Circular AC120-95.
X