Refine Your Search

Search Results

Viewing 1 to 12 of 12
Journal Article

Comparison of Diesel Spray Combustion in Different High-Temperature, High-Pressure Facilities

2010-10-25
2010-01-2106
Diesel spray experimentation at controlled high-temperature and high-pressure conditions is intended to provide a more fundamental understanding of diesel combustion than can be achieved in engine experiments. This level of understanding is needed to develop the high-fidelity multi-scale CFD models that will be used to optimize future engine designs. Several spray chamber facilities capable of high-temperature, high-pressure conditions typical of engine combustion have been developed, but because of the uniqueness of each facility, there are uncertainties about their operation. For this paper, we describe results from comparative studies using constant-volume vessels at Sandia National Laboratories and IFP.
Journal Article

Effects of Real-Fluid Thermodynamics on High-Pressure Fuel Injection Processes

2014-04-01
2014-01-1429
This paper first summarizes a new theoretical description that quantifies the effects of real-fluid thermodynamics on liquid fuel injection processes as a function of pressure at typical engine operating conditions. It then focuses on the implications this has on modeling such flows with emphasis on application of the Large Eddy Simulation (LES) technique. The theory explains and quantifies the major differences that occur in the jet dynamics compared to that described by classical spray theory in a manner consistent with experimental observations. In particular, the classical view of spray atomization as an appropriate model at some engine operating conditions is questionable. Instead, non-ideal real-fluid behavior must be taken into account using a multicomponent formulation that applies to hydrocarbon mixtures at high-pressure supercritical conditions.
Journal Article

Visualization of Ignition Processes in High-Pressure Sprays with Multiple Injections of n-Dodecane

2015-04-14
2015-01-0799
We investigate the mixing, penetration, and ignition characteristics of high-pressure n-dodecane sprays having a split injection schedule (0.5/0.5 dwell/0.5 ms) in a pre-burn combustion vessel at ambient temperatures of 750 K, 800 K and 900 K. High-speed imaging techniques provide a time-resolved measure of vapor penetration and the timing and progression of the first- and second-stage ignition events. Simultaneous single-shot planar laser-induced fluorescence (PLIF) imaging identifies the timing and location where formaldehyde (CH2O) is produced from first-stage ignition and consumed following second-stage ignition. At the 900-K condition, the second injection penetrates into high-temperature combustion products remaining in the near-nozzle region from the first injection. Consequently, the ignition delay for the second injection is shorter than that of the first injection (by a factor of two) and the second injection ignites at a more upstream location near the liquid length.
Journal Article

Visualization of Diesel Spray Penetration, Cool-Flame, Ignition, High-Temperature Combustion, and Soot Formation Using High-Speed Imaging

2009-04-20
2009-01-0658
Shadowgraph/schlieren imaging techniques have often been used for flow visualization of reacting and non-reacting systems. In this paper we show that high-speed shadowgraph visualization in a high-pressure chamber can also be used to identify cool-flame and high-temperature combustion regions of diesel sprays, thereby providing insight into the time sequence of diesel ignition and combustion. When coupled to simultaneous high-speed Mie-scatter imaging, chemiluminescence imaging, pressure measurement, and spatially-integrated jet luminosity measurements by photodiode, the shadowgraph visualization provides further information about spray penetration after vaporization, spatial location of ignition and high-temperature combustion, and inactive combustion regions where problematic unburned hydrocarbons exist. Examples of the joint application of high-speed diagnostics include transient non-reacting and reacting injections, as well as multiple injections.
Journal Article

Study of Soot Formation and Oxidation in the Engine Combustion Network (ECN), Spray A: Effects of Ambient Temperature and Oxygen Concentration

2013-04-08
2013-01-0901
Within the Engine Combustion Network (ECN) spray combustion research frame, simultaneous line-of-sight laser extinction measurements and laser-induced incandescence (LII) imaging were performed to derive the soot volume fraction (fv). Experiments are conducted at engine-relevant high-temperature and high-pressure conditions in a constant-volume pre-combustion type vessel. The target condition, called "Spray A," uses well-defined ambient (900 K, 60 bar, 22.8 kg/m₃, 15% oxygen) and injector conditions (common rail, 1500 bar, KS1.5/86 nozzle, 0.090 mm orifice diameter, n-dodecane, 363 K). Extinction measurements are used to calibrate LII images for quantitative soot distribution measurements at cross sections intersecting the spray axis. LII images are taken after the start of injection where quasi-stationary combustion is already established.
Technical Paper

The Effects of Mixture Stratification on Combustion in a Constant-Volume Combustion Vessel

1998-02-01
980159
The role of mixture stratification on combustion rate has been investigated in a constant volume combustion vessel in which mixtures of different equivalence ratios can be added in a spatially and temporally controlled fashion. The experiments were performed in a regime of low fluid motion to avoid the complicating effects of turbulence generated by the injection of different masses of fluid. Different mixture combinations were investigated while maintaining a constant overall equivalence ratio and initial pressure. The results indicate that the highest combustion rate for an overall lean mixture is obtained when all of the fuel is contained in a stoichiometric mixture in the vicinity of the ignition source. This is the result of the high burning velocity of these mixtures, and the complete oxidation which releases the full chemical energy.
Technical Paper

Submerged Electrical Discharges for Water Decontamination and Disinfection

2007-07-09
2007-01-3175
A modular and scalable Dense Medium Plasma Water Purification Reactor was developed, which uses atmospheric-pressure electrical discharges under water to generate highly reactive species to break down organic contaminants and microorganisms. Key benefits of this novel technology include: (i) extremely high efficiency in both decontamination and disinfection; (ii) operating continuously at ambient temperature and pressure; (iii) reducing demands on the containment vessel; and (iv) requiring no consumables. This plasma based technology was developed to replace the catalytic reactor being used in the planned International Space Station Water Processor Assembly.
Technical Paper

Quantitative Mixing Measurements in a Vaporizing Diesel Spray by Rayleigh Imaging

2007-04-16
2007-01-0647
This paper details the development and application of a Rayleigh imaging technique for quantitative mixing measurements in a vaporizing diesel spray under engine conditions. Experiments were performed in an optically accessible constant-volume combustion vessel that simulated the ambient conditions in a diesel engine. Two-dimensional imaging of Rayleigh scattering from a diesel spray of n-heptane and well-characterized ambient was accomplished by using a 532 nm Nd:YAG laser sheet and a low-noise back-illuminated CCD camera. Methods to minimize interference from unwanted elastic scattering sources (e.g. windows, particles) were investigated and are discussed in detail. The simultaneous measurement of Rayleigh scattering signal from the ambient and from the diesel spray provides important benefits towards making the technique quantitative and accurate.
Technical Paper

Formaldehyde Visualization Near Lift-off Location in a Diesel Jet

2006-10-16
2006-01-3434
Formaldehyde (HCHO) near the lift-off location in a reacting diesel jet was visualized using planar laser-induced fluorescence (PLIF). Simultaneous imaging of OH chemiluminescence identified the high-temperature combustion region (lift-off). Experiments were performed in a constant-volume combustion vessel at ambient gas conditions (temperature and oxygen concentration) that generate no-soot, low-soot and moderate-soot diesel jets during mixing-controlled combustion. For no-soot conditions, results show that HCHO is formed upstream of the lift-off location and is consumed downstream of the lift-off length in fuel-rich premixed reaction zones at the jet center. Despite the fuel-rich combustion, and downstream regions that are surrounded by a high-temperature diffusion flame, there is no detectable PAH formation in the no-soot condition.
Technical Paper

ELECTRONIC SYSTEM INTEGRATION FOR MARINE ENGINE APPLICATIONS

1994-09-01
941709
An open architecture of electronic controls and monitors has been conceived and developed to meet marine application requirements and provide vessel control features. Integration of this system reduces the number of components, improves reliability, and eases installation and troubleshooting. The architecture provides the plan for system integration, while allowing flexibility for customer component selection, system technology upgrades, and expansion with additional features. Serial links are used to provide the data channels within the modular style architecture and the communication ports to share information with the operators.
Technical Paper

Relationship Between Ignition Processes and the Lift-Off Length of Diesel Fuel Jets

2005-10-24
2005-01-3843
The reaction zone of a diesel fuel jet stabilizes at a location downstream of the fuel injector once the initial autoignition phase is over. This distance is referred to as flame lift-off length. Recent investigations have examined the effects of a wide range of parameters (injection pressure, orifice diameter, and ambient gas temperature, density and oxygen concentration) on lift-off length under quiescent diesel conditions. Many of the experimental trends in lift-off length were in agreement with scaling laws developed for turbulent, premixed flame propagation in gas-jet lifted flames at atmospheric conditions. However, several effects did not correlate with the gas-jet scaling laws, suggesting that other mechanisms could be important to lift-off stabilization at diesel conditions. This paper shows experimental evidence that ignition processes affect diesel lift-off stabilization.
Journal Article

Ducted Fuel Injection: Effects of Stand-Off Distance and Duct Length on Soot Reduction

2019-04-02
2019-01-0545
Ducted fuel injection (DFI) has been shown to be an effective method to significantly reduce soot formation in mixing controlled compression ignition (MCCI) diesel combustion. This reduction has been demonstrated in both combustion vessels and in an optical engine. The mechanisms driving the soot reduction are to date not fully understood. Optimal duct configurations are also not immediately evident. The objective of this study is to show the effects of two geometric variables, namely distance from fuel injector orifice exit to duct inlet (0.1-6 mm) for a 2x14 mm duct, and duct length variation (8-14 mm) at a given stand-off distance of 0.1 mm. A 138 μm on-axis single-orifice injector operated at 100-250 MPa was used in a heated, continuous flow, constant pressure vessel with optical access.
X