In an optically accessible high-pressure/high-temperature (HP/HT) chamber, OH radicals, soot concentration, and OH* chemiluminescence images were captured simultaneously at a constant ambient temperature of 823 K and a gas density of 20 kg/m3, with injection pressures of 800-2000 bar using an injector with nozzle orifice having a diameter of 0.1 mm. Swedish market sold MK1 diesel fuel was used in this study. The optical diagnostic methods used were the two-dimensional laser extinction for the soot concentration measurement, planar laser induced fluorescence for the OH radical measurement, OH* chemiluminescence imaging, and the natural flame luminosity imaging. The objective of this study is to explore the diesel spray structures under the low sooting and non-sooting conditions. In this study, it was found that the OH radical zone in the jet’s upstream region expanded to the jet center and the soot concentration decreased when the fuel injection pressure increased.