Refine Your Search

Search Results

Viewing 1 to 10 of 10
Technical Paper

Multi-Disciplinary Aerodynamics Analysis for Vehicles: Application of External Flow Simulations to Aerodynamics, Aeroacoustics and Thermal Management of a Pickup Truck

2007-04-16
2007-01-0100
During the design process for a vehicle, the CAD surface geometry becomes available at an early stage so that numerical assessment of aerodynamic performance may accompany the design of the vehicle's shape. Accurate prediction requires open grille models with detailed underhood and underbody geometry with a high level of detail on the upper body surface, such as moldings, trim and parting lines. These details are also needed for aeroacoustics simulations to compute wall-pressure fluctuations, and for thermal management simulations to compute underhood cooling, surface temperatures and heat exchanger effectiveness. This paper presents the results of a significant effort to capitalize on the investment required to build a detailed virtual model of a pickup truck in order to simultaneously assess performance factors for aerodynamics, aeroacoustics and thermal management.
Technical Paper

Side Window Buffeting Characteristics of an SUV

2004-03-08
2004-01-0230
Buffeting is a wind noise of high intensity and low frequency in a moving vehicle when a window or sunroof is open and this noise makes people in the passenger compartment very uncomfortable. In this paper, side window buffeting was simulated for a typical SUV using the commercial CFD software Fluent 6.0. Buffeting frequency and intensity were predicted in the simulations and compared with the corresponding experimental wind tunnel measurement. Furthermore, the effects of several parameters on buffeting frequency and intensity were also studied. These parameters include vehicle speed, yaw angle, sensor location and volume of the passenger compartment. Various configurations of side window opening were considered. The effects of mesh size and air compressibility on buffeting were also evaluated. The simulation results for some baseline configurations match the corresponding experimental data fairly well.
Technical Paper

Experimental & Computational Simulations Utilized During the Aerodynamic Development of the Dodge Intrepid R/T Race Car

2002-12-02
2002-01-3334
Experimental and computational simulation techniques were concurrently employed throughout the aerodynamic development of the NASCAR Dodge Intrepid R/T in order to achieve a greater understanding of the complex flow fields involved. With less than 500 days to design, understand, and build a competitive vehicle, the development team utilized a closed loop approach to testing. Scale wind tunnel models and Computational Fluid Dynamics (CFD) were used to identify program direction and to speed the development cycle versus the traditional process of full scale testing. This paper will detail the process and application of both the experimental and computational techniques used in the aerodynamic development of the Intrepid R/T race vehicle, primarily focusing on the earlier stages that led to its competition introduction at the start of the 2001 season.
Technical Paper

Attempts for Reduction of Rear Window Buffeting Using CFD

2005-04-11
2005-01-0603
This paper summarizes the major activities of CFD study on rear window buffeting of production vehicles during the past two years at DaimlerChrysler. The focus of the paper is the attempt to find suitable solutions for buffeting suppression using a developed procedure of CFD simulation with commercial software plus FFT acoustic post-processing. The analysis procedure has been validated using three representative production vehicles and good correlation with wind tunnel tests has been attained which has gained the confidence in solving the buffeting problem. Several attempts have been proposed and tried to find solution for buffeting reduction. Some of them are promising, but feasibility and manufacturability still need discussion. In order to find suitable solution for buffeting reduction, more basic research is necessary, more ideas should be collected, and more joint efforts of CFD and testing are imperative.
Technical Paper

A Semi-Empirical Model for Fast Residual Gas Fraction Estimation in Gasoline Engines

2006-10-16
2006-01-3236
Accurate accounting for fresh charge (fuel and air) along with trapped RGF is essential for the subsequent thermodynamic analysis of combustion in gasoline engines as well as for on-line and real-time quantification as relevant to engine calibration and control. Cost and complexity of such techniques renders direct measurement of RGF impractical for running engines. In this paper, an empirically-based approach is proposed for on-line RGF, based on an existing semi-empirical model [1]. The model developed expands the range over which the semi-empirical model is valid and further improves its accuracy. The model was rigorously validated against a well correlated GT-POWER model as well as results from 1D gas exchange model [2]. Overall, using this model, RGF estimation error was within ∼1.5% for a wide range of engine operating conditions. The model will be implemented in Dyno development and calibration at Chrysler Group.
Technical Paper

Parametric Analysis for the Design of Compact Heat Exchangers

2006-04-03
2006-01-1578
In this paper, the effects of heat exchanger design parameters are investigated. The ease study being investigated here is the parametric analysis of automotive radiator where the hot fluid is the engine coolant and the cold fluid is the ambient air. Key parameters that are considered are the air density, fin thickness, fins height and air temperature. Effect of air density may be a concern since heat exchangers are usually designed, for automotive applications, under atmospheric pressure conditions. Changes in altitude will cause a change in air density. Therefore, the performance of cooling system may be affected by elevation. In this analysis, however, it is shown that the change in air density has very limited or no effect on the cooling system. The fin dimensions play a key role in the overall effectiveness of a heat exchanger. Some cost saving ideas may include reducing fin dimensions such as fin thickness or fin height.
Technical Paper

Evaluation of Cylinder Pressure Transducer Accuracy based upon Mounting Style, Heat Shields, and Watercooling

2005-10-24
2005-01-3750
This investigation evaluated different pressure transducers in one cylinder to examine the combustion measurement differences between them simultaneously. There were a total of eleven transducers ranging in both diameter and type of transducer (piezo-electric, piezoresistive, and optical). Furthermore, the sensors differed in the methodology for minimizing signal distortion due to temperature. This methodology could take the form of various size mounting passages, heat shields, watercooling or heat transfer paths. To evaluate the sensors, different engine operating conditions were conducted, focusing at full load and low speeds. Other hardware configurations of the same engine family were used to exaggerate the combustion environment, specifically a tumble-motion plate and turbocharging.
Technical Paper

Heat Transfer Enhancement through Impingement of Flows and its Application in Lock-up Clutches

2005-04-11
2005-01-1936
An impinging-flow based methodology of enhancing the heat transfer in the grooves of a lockup clutch is proposed and studied. In order to evaluate its efficacy and reveal the mechanism, the three-dimensional flow within the groove was solved as a conjugate heat transfer problem in a rotating reference frame using the commercial CFD code FLUENT. The turbulence characteristics were predicted using k-ε model. The comparison of cooling effect was made between a simple baseline groove pattern and a typical flow-impingement based groove pattern of the same groove-to-total area ratio in terms of heat rejection ratio, maximum surface temperature, and heat transfer coefficient. It is found that more heat can be rejected with the impinging-flow based groove from the friction surface than with the baseline while the maximum surface temperature is lower in the former case.
Technical Paper

The DaimlerChrysler Full-Scale Aeroacoustic Wind Tunnel

2003-03-03
2003-01-0426
This paper provides an overview of the design and commissioning results for the DaimlerChrysler full-scale vehicle Aeroacoustic Wind Tunnel (AAWT) brought online in 2002. This wind tunnel represents the culmination of the plan for aeroacoustic facilities at the DaimlerChrysler Corporation Technical Center (DCTC) in Auburn Hills, Michigan. The competing requirements of excellent flow quality, low background noise, and constructed cost within budget were optimized using Computational Fluid Dynamics, extensive acoustic modeling, and a variety of scale-model experimental results, including dedicated experiments carried out in the 3/8-scale pilot wind tunnel located at DCTC. The paper describes the project history, user requirements, and design philosophy employed in realizing the facility. The AAWT meets all of DaimlerChrylser's performance targets, and was delivered on schedule. The commissioning results presented in this paper show its performance to be among the best in the world.
Technical Paper

Experimental and Modeling Evaluations of a Vacuum-Insulated Catalytic Converter

1999-10-25
1999-01-3678
Vehicle evaluations and model calculations were conducted on a vacuum-insulated catalytic converter (VICC). This converter uses vacuum and a eutectic PCM (phase-change material) to prolong the temperature cool-down time and hence, may keep the converter above catalyst light-off between starts. Tailpipe emissions from a 1992 Tier 0 5.2L van were evaluated after 3hr, 12hr, and 24hr soak periods. After a 12hr soak the HC emissions were reduced by about 55% over the baseline HC emissions; after a 24hr soak the device did not exhibit any benefit in light-off compared to a conventional converter. Cool-down characteristics of this VICC indicated that the catalyst mid-bed temperature was about 180°C after 24hrs. Model calculations of the temperature warm-up were conducted on a VICC converter. Different warm-up profiles within the converter were predicted depending on the initial temperature of the device.