Refine Your Search

Search Results

Viewing 1 to 7 of 7
Technical Paper

Electric Heating Regeneration of Large Wall-Flow Type DPF

1991-02-01
910136
Ceramic wall-flow type diesel particulate filters (DPF) are being investigated for the aftertreatment systems of heavy duty engines. To use ceramic DPF more reliably and easily, electric heating regenerations are studied varying combustion air flow rates and amounts of accumulated soot. Despite electric heater capacity limitations, it is possible to regenerate DPF at a certain combustion air flow rate without thermal shock failure. The maximum withstood temperature against thermal shock failure of electric heating regeneration is similar to that of diesel burner regeneration on DPF with a nine inch diameter and a twelve inch length.
Technical Paper

Analyses of Thermal Shock Failure on Large Volume DPF

1990-02-01
900113
Ceramic honeycomb wall flow diesel particulate filters (DPF) have been investigated for use in exhaust gas control of diesel vehicles. However, before they can be used, prevention of thermal shock failure during combustion regeneration is necessary. Studies were conducted on thermal shock failures on 9-inch diameter large volume DPF during regeneration by finite element analyses (FEA). These studies reveal that, within safe limits, maximum thermal stress is almost constant even at different gas flow rates and oxygen concentrations. Regeneration tests were also conducted on large volume DPF of several materials having different pore size distributions. FEA thermal stress was compared with mechanical strength of the material at safe levels.
Technical Paper

Improvement of Pore Size Distribution of Wall Flow Type Diesel Particulate Filter

1992-02-01
920144
To reduce flow restriction of the wall flow type diesel particulate filters, the pore size distribution of DPF material was improved. Large pore material is preferred to reduce the flow restriction of the DPF. However pore diameter should be controlled within a certain limit to maintain high trapping efficiency against diesel particulates. In order to solve these conflicting matters, the mean pore diameter was enlarged from 13μm of the current material to 20 μm or more, while maintaining the cumulative volume of pores above 100μm within 8% of the total pore volume. The safe limit against thermal shock failure of the improved DPF material having 9″D x 12″/, 12.5/ volume was also determined using diesel burner regeneration system.
Technical Paper

Thermal Reliability and Performance Improvement of Close-Coupled Catalytic Converter

1996-02-01
960565
This paper proposes a high temperature catalytic converter design using a ceramic substrate and intumescent matting. It also describes the improvement of converter performance using an advanced thin wall ceramic substrate. Due to future tightening of emission regulations and improvement of fuel economy, higher exhaust gas temperatures are suggested. Therefore, reduction of thermal reliability of an intumescent mat will be a concern because the catalytic converter will be exposed to high temperatures. For this reason, a new design converter has been developed using a dual cone structure for both the inlet and outlet cones. This minimizes heat conduction through the cone and decreases the temperature affecting the mat area. This design converter, without the use of a heat-shield, reduces the converter surface temperature to 441°C despite a catalyst bed temperature of 1050°C. The long term durability of the converter is demonstrated by the hot vibration test.
Technical Paper

Controlling of Heating Rates for Safe Regeneration of Ceramic Honeycomb Diesel Particulate Filter

1988-02-01
880002
Thermal shock failures have been considered as one of the most significant issues for wall flow type ceramic diesel particulate filters during their regeneration. This paper describes the experiments which were conducted in order to study effects of heating rates of the accumulated diesel particulate on the thermal shock failure of the filters using an NGK soot generator. The results showed favorable heating rates of the particulate in terms of the amounts of the accumulated particulate up to which the filters are safely regenerated.
Technical Paper

Effects of DPF Volume on Thermal Shock Failures during Regeneration

1989-02-01
890173
Application of ceramic honeycomb wall-flow type diesel particulate filters (DPF) to heavy duty vehicles requires a large volume filter. Heavy duty vehicles produce a large volume exhaust gas, and pressure drop in the exhaust system must be maintained to a certain level. In addition, the filters must be designed to resist fracture from thermal stresses during regeneration. This is particularly important in heavy duty vehicles because of these extended mileage requirements. These studies of the effects of DPF volume on thermal shock resistance during regeneration reveal that the maximum failure temperatures are lower as DPF volume is increased, still maintaining 950°C maximum temperature with 12 ℓ volume and 9″D × 12″L size large DPF. Some thermal stress analyses with temperature profiles and finite element analysis were conducted on four different volume DPF during regeneration.
Technical Paper

Effect of Cell Structure on Regeneration Failure of Ceramic Honeycomb Diesel Particulate Filter

1987-02-01
870010
In applying ceramic honeycomb wall flow type filters to the after-treatment systems of diesel particulate from engines, the melting and thermal shock failures of ceramic diesel particulate filters (DPF) have been considered as one of the most significant issues during regeneration. This paper gives the results of experiments on the effects of cell structure i.e., wall thickness and cell density, on the melting and thermal shock regeneration failure of DPF and proposes an optimized cell structure for DPF in terms of the regeneration failure and the pressure drop which is also considered to be one of the especially important issues in fuel economy for heavy duty vehicle application.