Refine Your Search

Topic

Search Results

Viewing 1 to 8 of 8
Technical Paper

Spacelab Neurovestibular Hardware

1991-07-01
911566
A set of devices for measurement of human balance orientation and eye movements in weightlessness was developed for neurovestibular experiments on Spacelab. The experiments involve astronaut motion, limb position changes, and moving visual fields, measurements are made of eye movements, muscular activity and orientation perception. This joint US/Canadian research program represent a group of closely related experiments designed to investigate space motion sickness, any associated changes in otolith-mediated responses occurring during weightlessness, and the continuation of changes to postflight conditions. The otoliths are a component of the vestibular apparatus which is located in the middle ear. It is responsible for maintaining the body's balance. Gravitational pull on the otoliths causes them to constantly appraise the nervous system of the position of the head with respect to the direction of gravity.
Technical Paper

Anthropometric and Blood Flow Characteristics Leading to EVA Hand Injury

2009-07-12
2009-01-2471
The aim of this study was to explore if fingernail delamination injury following EMU glove use may be caused by compression-induced blood flow occlusion in the finger. During compression tests, finger blood flow decreased more than 60%, however this occurred more rapidly for finger pad compression (4 N) than for fingertips (10 N). A pressure bulb compression test resulted in 50% and 45% decreased blood flow at 100 mmHg and 200 mmHg, respectively. These results indicate that the finger pad pressure required to articulate stiff gloves is more likely to contribute to injury than the fingertip pressure associated with tight fitting gloves.
Technical Paper

Additional Findings on the Multi-Modal Demands of “Voice-Command” Interfaces

2016-04-05
2016-01-1428
This paper presents the results of a study of how people interacted with a production voice-command based interface while driving on public roadways. Tasks included phone contact calling, full address destination entry, and point-of-interest (POI) selection. Baseline driving and driving while engaging in multiple-levels of an auditory-vocal cognitive reference task and manual radio tuning were used as comparison points. Measures included self-reported workload, task performance, physiological arousal, glance behavior, and vehicle control for an analysis sample of 48 participants (gender balanced across ages 21-68). Task analysis and glance measures confirm earlier findings that voice-command interfaces do not always allow the driver to keep their hands on the wheel and eyes on the road, as some assume.
Technical Paper

The Anatomy of Knock

2016-04-05
2016-01-0704
The combustion process after auto-ignition is investigated. Depending on the non-uniformity of the end gas, auto-ignition could initiate a flame, produce pressure waves that excite the engine structure (acoustic knock), or result in detonation (normal or developing). For the “acoustic knock” mode, a knock intensity (KI) is defined as the pressure oscillation amplitude. The KI values over different cycles under a fixed operating condition are observed to have a log-normal distribution. When the operating condition is changed (over different values of λ, EGR, and spark timing), the mean (μ) of log (KI/GIMEP) decreases linearly with the correlation-based ignition delay calculated using the knock-point end gas condition of the mean cycle. The standard deviation σ of log(KI/GIMEP) is approximately a constant, at 0.63. The values of μ and σ thus allow a statistical description of knock from the deterministic calculation of the ignition delay using the mean cycle properties
Technical Paper

Bio-Suit Development: Viable Options for Mechanical Counter Pressure

2004-07-19
2004-01-2294
Human explorers of planetary surfaces would benefit greatly from a spacesuit design that facilitates locomotion. To aid in the development of such an extravehicular activity suit, a design effort incorporating the concept of mechanical counter pressure (MCP) was undertaken. Three-dimensional laser scanning of the human body was used to identify the main effects of knee flexion angle on the size and shape of the leg. This laser scanning quantified the changes in shape that must be supported by an MCP garment and the tension that must be developed to produce even MCP. Evaluation of a hybrid-MCP concept using inextensible materials demonstrated strong agreement between experimental data and a mathematical model with rigid cylinder geometry. Testing of a form-fitting garment on the right lower leg of a subject demonstrated successful pressure production. Further research is required to evaluate how evenly pressure can be distributed using the hybrid-MCP concept.
Technical Paper

Experimental Learning: Hands on Experiments for Six Sigma Green and Black Belt Training, Part I – Manufacturing Environments

2006-04-03
2006-01-0794
Six Sigma methodologies in combination with Lean thinking have made considerable inroads as continuous improvement tools initially in manufacturing and more recently for service and transactional processes. There is considerable interest globally in training professionals on the use and application of these tools appropriate to either operational or transactional areas. It has long been realized that adult learning is at its best when participants are involved in relevant “hands-on” experiments. Six Sigma training has seen the use of class room demonstrations ranging from the use of playing cards, simulations and to the use of sophisticated experiments to illustrate concepts of factorial designs. This paper will focus on a series of simple but modular experiments that were developed over the past two years illustrating the application of all the Statistical tools that are taught as a part of Six Sigma Green and Black Belt body of knowledge.
Technical Paper

Modeling the Extravehicular Mobility Unit (EMU) Space Suit: Physiological Implications for Extravehicular Activity (EVA)

2000-07-10
2000-01-2257
Extravehicular activity (EVA) is investigated through experiments testing an actual extravehicular mobility unit (EMU) performing several EVA tasks in the laboratory, and a dynamic model of the EMU space suit is developed. Building directly on earlier work in EVA simulation, the space suit model was created from mass, inertia, and performance data to augment the unsuited 12-segment human model used in previous studies. A modified Preisach model was used to mathematically describe the hysteretic torque characteristics of joints in a pressurized space suit, and implemented numerically based on observed suit parameters. Computational simulations, based loosely on a 1995 EVA involving manipulation of the Spartan astrophysics payload, were performed to observe the effect of suit constraints on simulated astronaut performance.
Technical Paper

Engineering the 1999 Mercury Cougar Hybrid Instrument Panel

1999-03-01
1999-01-0692
In a joint effort between Ford Motor Company, Visteon Automotive Systems, Textron Automotive Company, and Dow Automotive the 1999 Mercury Cougar instrument panel (IP) was designed and engineered to reduce the weight and overall cost of the IP system. The original IP architecture changed from a traditional design that relied heavily upon the steel structure to absorb and dissipate unbelted occupant energy during frontal collisions to a hybrid design that utilizes both plastic and steel to manage energy. This design approach further reduced IP system weight by 1.88 Kg and yielded significant system cost savings. The hybrid instrument panel architecture in the Cougar utilizes a steel cross car beam coupled to steel energy absorbing brackets and a ductile thermoplastic substrate. The glove box assembly and the driver knee bolster are double shell injection molded structures that incorporate molded-in ribs for added stiffness.
X