Refine Your Search

Topic

Search Results

Viewing 1 to 17 of 17
Technical Paper

Effect of Gas-Pressure Stabilizers on Performance Characteristics of a Single-Cylinder Diesel Engine

1990-02-01
900641
Experimental investigation on a high speed single-cylinder diesel engine has shown that a gas-pressure stabilizer in the exhaust system has obvious effect upon engine performance. Two types of such gas pressure stabilizers were tested, and a reduction of about 0.5% to 2% in fuel consumption rate was achieved, which was mainly dependent on the type of stabilizer employed and was more significant under higher speed conditions.
Technical Paper

Numerical Calculation and Experimental Research on the Slip of Silicone Oil Fan Clutch

2021-04-06
2021-01-0807
In the existing literature concerning the calculation of the output speed of the silicone oil fan clutch and the silicone oil temperature, the theoretical calculation method is all adopted to establish the calculation formulas of moment transmission and silicone oil shear viscous heat by extracting the structural parameters of the clutch model, in order to solve the output speed and silicone oil temperature of the clutch under stable working state. At present, CFD (Computational Fluid Dynamics) numerical simulation method has not been used to solve the problem. In this paper, the CFD simulation method is used for the first time. Considering the change of silicone oil viscosity with temperature, a double-sided slot silicone oil fan clutch was taken as the research object to established the CFD simulation model of hydro-viscous drive to solve the clutch output speed and silicone oil temperature.
Technical Paper

Experimental Study on Hydraulic Pressure Feedforward and Feedback PID Control of I-EHB System with Friction Disturbance

2021-04-06
2021-01-0979
This paper designs the important components and structure of the integrated electro-hydraulic brake system (I-EHB). Firstly, the simplified linear system is modeled, and the transfer function without considering the nonlinear disturbance such as system friction is derived, and the correctness of the linear system is preliminarily verified by AMESim. Then set up the I-EHB system test bench, and use the Stribeck friction model to identify the friction torque parameters in the static and kinetic friction stages of the system to obtain a more accurate friction model. Finally, based on the I-EHB system model of friction disturbance, a pressure-speed-current three-loop cascade PID controller is designed, and a feedforward controller based on the system model is added to form the control structure of “pressure feedforward compensation + pressure-speed-current closed-loop cascade PID”.
Technical Paper

Research on the Bionic Design and Performance of Engine Cooling Fan with Blade Tip Serrated

2022-03-29
2022-01-0173
Turbulence caused by the blade tip of engine cooling fan is one of important noise generating factors. Existing theoretical researches show that the bionic serrated designs applied at the front and rear edges of fan blades can effectively improve the airflow characteristics and reduce the aerodynamic noise. However, the effect of its application at the blade tip needs to be explored and verified. In this research, vehicle engine fans whose tips are designed and remodeled with different size of triangular serrated edge have been tested on airduct, to explore the fan static pressure and noise that caused by changing of period and amplitude size. The large eddy simulation (LES) and FW-H acoustic analogy method are adopted to calculate the transient noise of each designed fan.
Technical Paper

Dynamic Modeling Method of Electric Vehicle Thermal Management System Based on Improved Moving Boundary Method

2022-03-29
2022-01-0183
The thermal management system, which is used to improve driving safety and thermal comfort, is one of the most important systems in electric vehicles. In recent years, researchers have coupled the heat pump system and the battery cooling system to effectively improve the heating COP (Coefficient of Performance). Therefore an accurate dynamic model of thermal management system plays a key role in investigating system performance and optimal control strategies. In this paper, an electric vehicle thermal management system based on four-way valve heat pump system is designed. The moving boundary method is improved by considering the unsteady flow of the external fluid, and then a 13-order dynamic model of the thermal management system is established. Firstly, the control equations of evaporator, condenser and chiller are derived according to the principle of conservation, and then a dynamic model of thermal management system is established in Simulink.
Technical Paper

Research on Thermal Recession Compensation Method of Disc Brakes

2023-04-11
2023-01-0668
If a car is braked frequently or at high speed, the thermal decay of brake system performance appears, which reduces the braking performance of the car. To compensate brake moment reduction during braking at thermal decay of brake system, a compensation strategy of brake moment is designed by using “feedforward +PID feedback” to pressure at wheel braking cylinder. The trigger and exit conditions of the strategy for the wheel cylinder pressure are proposed based on the threshold. A vehicle model consisting braking system is established if a vehicle runs at straight line, and the braking distance and braking acceleration are estimated, the results shown that the thermal decay compensation control strategy proposed in this paper can reduce the braking distance and braking time.
Technical Paper

Modeling of Gas Charging and Discharging for Airbag Suspension System and Control of Height Adjustment

2023-04-11
2023-01-0660
Taking a closed airbag suspension system as studying objects, the nonlinear dynamic model of the reservoir, compressor, solenoid valve, pipeline and air spring is established. The compressor exhaust volume, solenoid valve flow rate and air spring charging and discharging rate are calculated and compared with experiment to validate the model. Taking pressure difference and height adjustment rate under different working conditions of an airbag suspension as control measures, a control strategy is developed based on the established nonlinear dynamic model. The result indicates that when the vehicle is in curb weight, design weight and GVW (gross vehicle weight), the working time of the compressor can be reduced by 13.6%, 15.1% and 46.5%, respectively, compared with the conventional mode, during a height adjustment cycle. Then a state observer is proposed to estimate the steady-height for reducing the disturbance of measured height from road excitation.
Technical Paper

Dynamic Model and Experimental Research of Novel Air Spring with Parallel Unidirectional Pipes and Single Additional Chamber

2021-04-06
2021-01-0315
A new single-attachment air spring system with a parallel one-way tube is designed as a vibration isolation device for vehicles. The dynamics model of the new two-throttle tube air spring is established first, and the accuracy of the two-tube model is verified experimentally. Finally, the experimental results of the two-throttle tube air spring and the single-tube air spring are compared to analyze the effects of the tube diameter, tube length and additional air chamber volume on the dynamic stiffness of the two-throttle tube air spring. The results show that the combination of throttle tubes of different diameters has a great influence on the stiffness and damping characteristics of the air spring.
Journal Article

Numerical Investigation on the Internal Flow Field of Electronic Expansion Valve as the Throttle Element

2022-03-29
2022-01-0318
As one of the key components of the heat pump system, the electronic expansion valve mainly plays the role of throttling and reducing pressure in the heat pump system. The refrigerant flowing through the orifice will produce complex phase change. It is of great significance to study the internal flow field by means of CFD calculations. Firstly, a three-dimensional fluid model is established and the mesh is divided. Secondly, the phase change model is selected, the material is defined and the boundary conditions are determined. According to the principle of the fluid passing through thin-walled small holes, the flow characteristics of electronic expansion valve are theoretically analyzed. Then the flow characteristics of expansion valve are numerically calculated, and a bench for testing mass flow rate of the expansion valve is built. Then the theoretical value, CFD value and experimental value are compared to verify the correctness of the established three-dimensional fluid model.
Technical Paper

Study on Driving Forms and Control of Engine Cooling Fan

2023-04-11
2023-01-0816
The influence of engine cooling fan on the working state of engine cooling system under different driving forms and control strategy is studied, and a simulation model of engine thermal management system of a commercial vehicle is established. The model takes into account the measured performance parameters of the cooling system components, the gear shift logic of the transmission, the effect of vehicle speed on the airflow rate of the radiator, and proposes a modeling method for different cooling fan driving forms. The performance parameters such as engine outlet coolant temperature and corresponding cooling fan speed under different vehicle speeds and engine loads are calculated and analyzed by using the established model. The road measurement test of the engine thermal management system under the same working condition was carried out to read the relevant data from the engine ECU and confirm the reliability of the data.
Technical Paper

Calculation of Cooling Fan Blade Deformation and Aerodynamic Performance Based on Fluid-Structure Model

2023-04-11
2023-01-0815
Considering the interaction between fan blades and the surrounding air when a cooling fan rotates, the Fluid-Structure Interaction (FSI) model of the fan is established, and flow rate, static pressure, efficiency versus speed of the fan are calculated and analyzed. The aerodynamic performance of the fan is carried out, and the measured performance parameters are compared with calculated to validate the developed model. Using the established model, the performance of fans with different rotating speeds, diameters and blade installation angles is calculated. The effects of fan speed, diameter and blade installation angle on blade deformation and aerodynamic performance are studied.
Technical Paper

Modeling and Simulation Analysis of Electric Vehicle Battery Cooling System

2023-04-11
2023-01-0771
A battery cooling system model of electric vehicle was established. The system model consists of a battery pack, a pump, a radiator, and a fan. A cooling plate was used to cool the battery pack, and the coolant flow rate in the cooling plate was controlled by the pump. The heat in the battery cooling system was released into the ambient air through the radiator. A finite element analysis model of the cooling plate was established to calculate the pressure drop of the cooling plate. A coupled dynamics model of the battery pack-radiator cooling system was established to simulate the temperature of the battery pack during charging and discharging. Tests were carried out to obtain the pressure drop of the cooling plate and the temperature of the battery pack under different working conditions. The simulation results and test results were compared and analyzed, and the accuracy of the models were verified.
Technical Paper

Modeling and Control Strategy for Engine Thermal Management System

2024-04-09
2024-01-2234
In order to study the influence of engine silicone oil fan clutch on the performances of engine cooling system under different control strategies, a model of engine cooling system for light truck is established. The working characteristics of the silicone oil clutch and the measured performance parameters of the cooling system components are taken into account in our proposed model. Modeling methods for different silicone oil fan control strategies are also given. Using the established model, the performance parameters under different vehicle speeds, such as coolant temperature of engine outlet and power consumption of cooling fan, are calculated and analyzed. The in-suite measurement of the engine cooling system is carried out to get the temperatures of engine coolant inlet and outlet from engine ECU. The model is validated by the comparison between the calculation and the measured results.
Technical Paper

Numerical Investigation on Heat Dissipation Performance of Multi-Fan Cooling Module

2024-04-09
2024-01-2587
To study the heat dissipation performance of the multi-fan cooling module composed of multiple fans and a radiator, numerical models of the radiator and the multi-fan cooling module were established, and heat dissipation performance prediction analysis and application analysis were conducted. In modeling, the Effectiveness-Number of Transfer Units (ε − NTU) method is used to predict the heat dissipation performance of the radiator. The aerodynamic performance of the fan at any speed is obtained by the similarity theorem using the data obtained from the tests at a certain speed. The influence between the fan and the radiator was established by using the flow addition scheme. To validate the established model, heat dissipation performance using 36 radiators and 11 multi-fan cooling modules is measured, and the measured data are compared with the calculations.
Technical Paper

Research on the Flow and Heat Exchange Performance of the Chiller for Electric Vehicles

2024-04-09
2024-01-2412
A set of enthalpy difference test equipment is set up to test flow and heat exchange performance of chillers. The empirical correlations for the convective heat transfer coefficients on the coolant side and the refrigerant side are obtained by fitting the test data, and a two-particle lumped parameter model of the chiller is established. Based on this, the heat exchange performance of the chiller under different operating conditions is given. The effects of herringbone corrugated plate parameters, including angle, pitch, and depth, on flow and heat exchange performance of chillers under different flow rates are further studied. Using the Wilson plot method in test design, the thermal resistance of convective heat transfer on each side is separated from the total thermal resistance to calculate the convective heat transfer coefficient.
Technical Paper

Topological Optimization Design of Cooling Channel for Liquid-Cooled Plate of Power Battery

2024-04-09
2024-01-2676
The influence of the channels of a liquid-cooled plate on the heat dissipation performance of battery module is investigated in this paper. A topology optimization method for obtaining channel configurations of the liquid cooled plate is presented. Firstly, the battery pack cooling system test platform is built to test the flow resistance of the liquid-cooled plate under different flow rates and the maximum temperature and temperature difference of the battery under different working conditions. Secondly, the geometric model of the battery pack is established, and CFD software is used to simulate according to the test conditions. The test results validate the correctness of the model. Then, taking the average surface temperature of the liquid-cooled plate as the optimization objective, the topology optimization structure of the liquid-cooled plate is obtained by variable density method.
Technical Paper

Performance Calculation and Analysis of Engine Cooling Fan Based on Bidirectional Fluid Structure Coupling

2024-04-09
2024-01-2813
When the automotive engine cooling fan is actually working, there is a process of interaction and coupling between the fluid and solid domains on the blades. In order to study the influence of the "fluid structure coupling" effect on the aerodynamic and structural performance of fans during operation, a fan performance calculation model was established with and without considering the fluid structure coupling effect of fans. We conducted aerodynamic performance tests on fans, tested the relationship between fan flow rate, static pressure, transmission efficiency and fan speed, and compared and analyzed the calculated fan performance. The aerodynamic performance and structural deformation of the fan were calculated under different flow rates, rotational speeds and environmental temperatures, with and without considering the coupling of fan blades and airflow. The calculation results were compared and analyzed.
X