Design and Test Results of Reversible Loop Heat Pipe

1999-07-12
1999-01-2053
In typical loop heat pipe (LHP) applications, the LHP design calls for a dedicated evaporator and a dedicated condenser. Applications exist for reversible loop heat pipes (LHPs), which can transport heat in either direction. In the reversible LHP design, two evaporator pumps are plumbed together, one which acts as an evaporator while the other acts as a condenser. The two pumps can reverse roles, simply by reversing the temperature gradient across the loop. Thus, either pump can be used as an evaporator or a condenser, depending upon the environment. Reversible LHPs can be used to share heat between components, or to cross-strap opposing spacecraft radiators. A reversible LHP was built and tested to demonstrate feasibility and to characterize its performance capabilities and attributes. The device was tested by either alternately heating each evaporator electrically or by inducing a temperature difference between the two ends of the device.