Refine Your Search

Search Results

Technical Paper

Dew Point Analysis Developments for Space Station

1994-06-01
941511
This paper reviews the recent G189A computer program developments in the area of humidity control for the U.S. Lab Module in the Space Station. The humidity control function is provided as an indirect or passive function by the Common Cabin Air Assemblies (CCAA) in pressurized elements or modules in the Space Station. The CCAAs provide active cabin temperature control through implementation of a digital/electromechanical control system (i.e., a proportional/integral (PI) control system). A selected cabin temperature can be achieved by this control system as long as the sensible and latent heat loads are within specified limits. In this paper three pertinent analytical cases directed to determining minimum or maximum dew point temperatures are discussed. In these cases the basic sensible heat loads are set at constant values.