Refine Your Search

Search Results

Standard

Windshield Washer Tubing

2006-03-03
HISTORICAL
J1037_200603
This SAE Standard covers nonreinforced, extruded, flexible tubing intended primarily for use as fluid lines for automotive windshield washer systems which conform to the requirements of SAE J942.
Standard

Windshield Washer Tubing

2001-08-07
HISTORICAL
J1037_200108
This SAE Standard covers nonreinforced, extruded, flexible tubing intended primarily for use as fluid lines for automotive windshield washer systems which conform to the requirements of SAE J942.
Standard

WINDSHIELD WASHER TUBING

1987-12-01
HISTORICAL
J1037_198712
This SAE Standard covers nonreinforced, extruded, flexible tubing intended primarily for use as fluid lines for automotive windshield washer systems conforming to the requirements of SAE J942.
Standard

Windshield Washer Tubing

2015-04-21
CURRENT
J1037_201504
This SAE Standard covers nonreinforced, extruded, flexible tubing intended primarily for use as fluid lines for automotive windshield washer systems which conform to the requirements of SAE J942.
Standard

Low-Permeation Fuel Fill and Vent Tube

2021-09-14
CURRENT
J2405_202109
This SAE Standard covers the minimum requirements for a low-permeation tubing (100 g/m2/day or less) for use as a low pressure (14.5 kPa) liquid- or vapor-carrying component for use in gasoline or diesel fuel filler, vent, and vapor systems. The construction shall be designed to be functional over a temperature range of -40 to 100 °C for the T1 designation, or -40 to 125 °C for the T2 designation.
Standard

Low-Permeation Fuel Fill and Vent Tube

1997-08-01
HISTORICAL
J2405_199708
This SAE Standard covers the minimum requirements for a low-permeation tubing (100 g/m2·day or less) for use as a low pressure (14.5 kPa) liquid- or vapor-carrying component for use in gasoline or diesel fuel filler, vent, and vapor systems. The construction shall be designed to be functional over a temperature range of –40 °C to 100 °C for the T1 designation, or –40 °C to 125 °C for the T2 designation.
Standard

Low-Permeation Fuel Fill and Vent Tube

2007-07-02
HISTORICAL
J2405_200707
This SAE Standard covers the minimum requirements for a low-permeation tubing (100 g/m2·day or less) for use as a low pressure (14.5 kPa) liquid- or vapor-carrying component for use in gasoline or diesel fuel filler, vent, and vapor systems. The construction shall be designed to be functional over a temperature range of –40 °C to 100 °C for the T1 designation, or –40 °C to 125 °C for the T2 designation.
Standard

FUEL AND OIL HOSES

1981-09-01
HISTORICAL
J30_198109
This specification covers three types of fuel and oil hose, coupled and uncoupled, for use with gasoline oil and diesel fuel.
Standard

FUEL AND OIL HOSES

1963-06-01
HISTORICAL
J30_196306
This specification covers one type and one style of fuel and oil hose, coupled and uncoupled, for use with gasoline, oil, or diesel fuel.
Standard

FUEL AND OIL HOSES

1961-06-01
HISTORICAL
J30_196106
This specification covers one type and one style of fuel and oil hose, coupled and uncoupled, for use with gasoline, oil, or diesel fuel.
Standard

FUEL AND OIL HOSES

1977-02-01
HISTORICAL
J30D_197702
This specification covers hose which may be supplied either coupled or uncoupled for use with gasoline, diesel fuel, lubricating oil, or the vapor present in either the fuel system or in the crankcase of internal combustion engines in mobile, stationary, and marine applications. The hose may be furnished in long lengths, specific cut lengths, or as a part preformed to a specific configuration.
Standard

FUEL AND OIL HOSES

1976-03-01
HISTORICAL
J30C_197603
This specification covers hose which may be supplied either coupled or uncoupled for use with gasoline, diesel fuel, lubricating oil, or the vapor present in either the fuel system or in the crankcase of internal combustion engines in mobile, stationary, and marine applications. The hose may be furnished in long lengths, specific cut lengths, or as a part preformed to a specific configuration.
Standard

AUTOMOTIVE AIR CONDITIONING HOSE

1988-07-01
HISTORICAL
J51_198807
This specification covers reinforced rubber and reinforced thermoplastic hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of -30 to 120°C (-22 to 248°F). Specific construction details are to be agreed upon between user and supplier.
Standard

AUTOMOTIVE AIR CONDITIONING HOSE

1985-05-01
HISTORICAL
J51_198505
This specification covers reinforced rubber and reinforced thermoplastic hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of −30 to 120°C (−22 to 248°F). Specific construction details are to be agreed upon between user and supplier.
Standard

Refrigerant 12 Automotive Air-Conditioning Hose

1998-08-01
HISTORICAL
J51_199808
This SAE Standard covers reinforced hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of −30 to 120 °C (−22 to 248 °F). Specific construction details are to be agreed upon between user and supplier.1
Standard

AUTOMOTIVE AIR-CONDITIONING HOSE

1989-05-01
HISTORICAL
J51_198905
This specification covers reinforced rubber and reinforced thermoplastic hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of -30 to 120°C (-22 to 248°F). Specific construction details are to be agreed upon between user and supplier.
X