Journal Article
A Study of an Integrated HVAC-Vehicle Model for Automotive Vehicles
2018-04-18
Abstract The objective of this work is to develop an integrated HVAC-VEHICLE model for climate control studies. A published lumped parameter based HVAC model has been used as the framework for the HVAC modeling with some modifications to realize the climate control and to improve the robustness of the model. R134a (1,1,2,2-Tetrafluoroethane) has been used as the refrigerant fluid in this study. The stand-alone HVAC model has been compared qualitatively with the experimental works available in the literature. The experimental trends of the thermodynamic and performance related parameters of HVAC are reasonably well captured by the HVAC model. In particular, Coefficient of Performance (CoP) was found to decrease with increase in compressor speed and increase in ambient temperature but increase with increase in evaporator blower mass flow rate.