Refine Your Search

Search Results

Viewing 1 to 13 of 13
Journal Article

Standardized Electrical Power Quality Analysis in Accordance with MIL-STD-704

2010-11-02
2010-01-1755
MIL-STD-704 defines power quality in terms of transient, steady-state, and frequency-domain metrics that are applicable throughout a military aircraft electric power system. Maintaining power quality in more electric aircraft power systems has become more challenging in recent years due to the increase in load dynamics and power levels in addition to stricter requirements of power system characteristics during a variety of operating conditions. Further, power quality is often difficult to assess directly during experiments and aircraft operation or during data post-processing for the integrated electric power system (including sources, distribution, and loads). While MIL-STD-704 provides guidelines for compliance testing of electric load equipment, it does not provide any instruction on how to assess the power quality of power sources or the integrated power system itself, except the fact that power quality must be satisfied throughout all considered operating conditions.
Journal Article

Impact of Transient Operating Conditions on Electrical Power System and Component Reliability

2014-09-16
2014-01-2144
Transient operating conditions in electrical systems not only have significant impact on the operating behavior of individual components but indirectly affect system and component reliability and life. Specifically, transient loads can cause additional loss in the electrical conduction path consisting of windings, power electronic devices, distribution wires, etc., particularly when loads introduce high peak vs. average power ratios. The additional loss increases the operating temperatures and thermal cycling in the components, which is known to reduce their life and reliability. Further, mechanical stress caused by dynamic loading, which includes load torque cycling and high peak torque loading, increases material fatigue and thus reduces expected service life, particularly on rotating components (shaft, bearings).
Journal Article

A Direct Torque-Controlled Induction Machine Bidirectional Power Architecture for More Electric Aircraft

2009-11-10
2009-01-3219
The performance of a more-electric aircraft (MEA) power system electrical accumulator unit (EAU) architecture consisting of a 57000 rpm induction machine (IM) coupled to a controllable shaft load and controlled using direct torque control (DTC) is examined through transient modeling and simulation. The simplicity and extremely fast dynamic torque response of DTC make it an attractive choice for this application. Additionally, the key components required for this EAU system may already exist on certain MEA, therefore allowing the benefits of EAU technology in the power system without incurring a significant weight penalty. Simulation results indicate that this architecture is capable of quickly tracking system bus power steps from full regenerative events to peak load events while maintaining the IM's speed within 5% of its nominal value.
Technical Paper

Real-time Thermal Observer for Electric Machines

2006-11-07
2006-01-3102
A temperature estimation algorithm (thermal observer) that provides accurate estimates of the thermal states of an electric machine in real time is presented. The thermal observer is designed to be a Kalman filter that combines thermal state predictions from a lumped-parameter thermal model of the electric machine with temperature measurements from a single external temperature sensor. An analysis based on the error covariance matrix of the Kalman filter is presented to guide the selection of the best sensor location. The thermal observer performance is demonstrated using a 3.8 kW permanent-magnet machine. Comparison of the thermal observer estimates and the actual temperatures demonstrate that this approach can provide accurate knowledge of the machine's thermal states despite modeling uncertainty and unknown initial machine thermal states.
Technical Paper

Simulation of MADMEL Power Systems Components

1998-04-21
981258
Detailed computer models of system components for More Electric Aircraft have been developed using the Advanced Control System Language (ACSL) and its graphical front-end, Graphic Modeller. Among the devices modeled are a wound-rotor synchronous generator with parallel bridge-rectifier outputs, a switched-reluctance generator, and various loads including a DC-DC converter, an inverter-driven induction motor, and an electro-hydrostatic actuator. Results from the simulations are presented together with corroborating experimental test results.
Technical Paper

Integrated Electrical System Model of a More Electric Aircraft Architecture

2008-11-11
2008-01-2899
A primary challenge in performing integrated system simulations is balancing system simulation speeds against the model fidelity of the individual components composing the system model. Traditionally, such integrated system models of the electrical systems on more electric aircraft (MEA) have required drastic simplifications, linearizations, and/or averaging of individual component models. Such reductions in fidelity can take significant effort from component engineers and often cause the integrated system simulation to neglect critical dynamic behaviors, making it difficult for system integrators to identify problems early in the design process. This paper utilizes recent advancements in co-simulation technology (DHS Links) to demonstrate how integrated system models can be created wherein individual component models do not require significant simplification to achieve reasonable integrated model simulation speeds.
Technical Paper

A Modular Power System Architecture for Military and Commercial Electric Vehicles

2010-11-02
2010-01-1756
Numerous modern military and commercial vehicles rely on portable, battery-powered sources for electric energy. Due to their highly specialized functions these vehicles are typically custom-designed, produced in limited numbers, and expensive. To mitigate the power system's contribution to these undesirable characteristics, this paper proposes a modular power system architecture consisting of “smart” power battery units (SPUs) that can be readily interconnected in numerous ways to provide distributed and coordinated system power management. The proposed SPUs contain a battery power source and a power electronics converter. They are compatible with multiple battery chemistries (or any energy storage device that can produce a terminal voltage), allowing them to be used with both existing and future energy storage technologies.
Technical Paper

Designing a Parallel-Through-the-Road Plug-in Hybrid Electric Vehicle

2012-09-10
2012-01-1763
The Purdue University EcoMakers team has completed its first year of the EcoCAR 2 Competition, in which the team has designed a Parallel-Through-the-Road Plug-in Hybrid Electric Vehicle that meets the performance requirements of a mid-size sedan for the US market, maintaining capability, utility and consumer satisfaction while minimizing emissions, energy consumption and petroleum use. The team is utilizing a 1.7L 14 CI engine utilizing B20 (20% biodiesel, 80% diesel), a 16.2 kW-hr A123 battery pack, and a Magna E-Drive motor to power the front and rear wheels. This will allow the vehicle to have a charge-depleting range of 75 miles. The first year was focused on the simulation of the vehicle, in which the team completed the controls, packaging and integration, and electrical plans for the vehicle to be used and implemented in years two and three of the competition.
Technical Paper

Design of a High-Temperature Utility Electromechanical Actuator

2012-10-22
2012-01-2214
Electric actuation on aerospace platforms has significant advantages compared to its hydraulic counterparts, particularly in terms of enhanced reliability, reduced maintenance, advanced diagnostic/performance capabilities, and possibly reduced weight and cost. It is thus not surprising that military and commercial aerospace sectors are introducing more electrical actuation architectures. A logical continuation of this trend is the replacement of hydraulic utility actuators in applications with harsh environments such as wide-range ambient temperatures and high vibration, where hydraulic actuation is still dominating. Such environments provide new challenges to the design of electric actuators, particularly considering that performance, weight, volume, and cost should be competitive with the equivalent hydraulic systems.
Technical Paper

Large Displacement Stability by Design for Robust Aircraft Electric Power Systems

2012-10-22
2012-01-2197
More electric aircraft (MEA) architectures have increased in complexity leading to a demand for evaluating the dynamic stability of their advanced electrical power systems (EPS). The system interactions found therein are amplified due to the increasingly integrated subsystems and on-demand power requirements of the EPS. Specifically, dynamic electrical loads with high peak-to-average power ratings as well as regenerative power capabilities have created a major challenge in design, control, and integration of the EPS and its components. Therefore, there exists a need to develop a theoretical framework that is feasible and useful for the specification and analysis of the stability of complex, multi-source, multi-load, reconfigurable EPS applicable to modern architectures. This paper will review linear and nonlinear system stability analysis approaches applicable to a scalable representative EPS architecture with a focus on system stability evaluation during large-displacement events.
Technical Paper

Developing Analysis for Large Displacement Stability for Aircraft Electrical Power Systems

2014-09-16
2014-01-2115
Future more electric aircraft (MEA) architectures that improve electrical power system's (EPS's) source and load utilization will require advance stability analysis capabilities. Systems are becoming more complex with bidirectional flows from power regeneration, multiple sources per channel and higher peak to average power ratios. Unknown load profiles with large transients complicate common stability analysis techniques. Advancements in analysis are critical for providing useful feedback to the system integrator and designers of multi-source, multi-load power systems. Overall, a framework for evaluating stability with large displacement events has been developed. Within this framework, voltage transient bounds are obtained by identifying the worst case load profile. The results can be used by system designers or integrators to provide specifications or limits to suppliers. Subsystem suppliers can test and evaluate their design prior to integration and hardware development.
Technical Paper

Power Quality Analysis Framework for AC and DC Electrical Systems

2014-09-16
2014-01-2209
Analyzing and maintaining power quality in an electrical power system (EPS) is essential to ensure that power generation, distribution, and loads function as expected within their designated operating regimes. Standards such as MIL-STD-704 and associated documents provide the framework for power quality metrics that need to be satisfied under varying operating conditions. However, analyzing these power quality metrics within a fully integrated EPS based solely on measurements of relevant signals is a different challenge that requires a separate framework containing rules for data acquisition, metric calculations, and applicability of metrics in certain operating conditions/modes. Many EPS employed throughout industry and government feature various alternating-current (ac) power systems.
Journal Article

Electrical Accumulator Unit for the Energy Optimized Aircraft

2008-11-11
2008-01-2927
The movement to more-electric architectures during the past decade in military and commercial airborne systems continues to increase the complexity of designing and specifying the electric power system. In particular, the electrical power system (EPS) faces challenges in meeting the highly dynamic power demands of advanced power electronics based loads. This paper explores one approach to addressing these demands by proposing an electrical equivalent of the widely utilized hydraulic accumulator which has successfully been employed in hydraulic power system on aircraft for more than 50 years.
X