Refine Your Search

Topic

Search Results

Standard

RATE OF CLIMB INDICATOR, PRESSURE ACTUATED (VERTICAL SPEED INDICATOR)

2008-02-16
CURRENT
AS394A
This Aeronautical Standard covers four (4) basic types of direct indicating instruments as follows: TYPE I - Range 0-2000 feet per minute climb and descent TYPE II - Range 0-3000 feet per minute climb and descent TYPE III - Range 0-4000 feet per minute climb and descent TYPE IV - Range 0-6000 feet per minute climb and descent
Standard

Directional Indicating System (Turbine Powered Subsonic Aircraft)

2020-04-14
CURRENT
ARP416B
This recommended practice covers the requirements for gyroscopically stabilized Directional Indicating Systems, which will operate as a 1°/hour latitude corrected, free directional gyro or as a slaved gyro, magnetic compass with 1/2° accuracy.
Standard

Automatic Pilot Installations

2008-02-16
HISTORICAL
ARP419A
These recommendations cover the mechanical and electrical installation and installation test procedures for automatic pilots of the type normally used in transport type aircraft. The material in this ARP does not supercede any airworthiness requirement in the Civil Air Regulations.
Standard

AUTOMATIC PILOT INSTALLATIONS

1991-05-01
HISTORICAL
ARP419
These recommendations cover the mechanical and electrical installation and installation test procedures for automatic pilots of the type normally used in transport type aircraft. The material in this ARP does not supercede any airworthiness requirement in the Civil Air Regulations.
Standard

Automatic Pilot Installations

2020-04-14
CURRENT
ARP419B
These recommendations cover the mechanical and electrical installation and installation test procedures for automatic pilots of the type normally used in transport type aircraft. The material in this ARP does not supercede any airworthiness requirement in the Civil Air Regulations.
Standard

Minimum Performance Standard Stall Warning Equipment

2020-12-22
CURRENT
AS8014A
This Aerospace Standard covers two basic Stall Warning Systems, one measures air flow and pressure distribution on the airfoil and the other measures the angle of airflow with respect to an arbitrary reference line. Each type of system includes, as a minimum, a sensor and the means for activating a device which warns the pilot of an impending stall.
Standard

MINIMUM PERFORMANCE STANDARD STALL WARNING EQUIPMENT

1986-09-08
HISTORICAL
AS8014
This Aerospace Standard covers two basic Stall Warning Systems, one measures air flow and pressure distribution on the airfoil and the other measures the angle of airflow with respect to an arbitrary reference line. Each type of system includes, as a minimum, a sensor and the means for activating a device which warns the pilot of an impending stall.
Standard

PRECISION MOTOR TACHOMETER GENERATOR

2008-02-16
CURRENT
ARP667
This recommended practice establishes objectives for high performance control motor tachometer generators to be used with aeronautical and associated equipment in protective enclosures or completely within the shell of the aircraft so that they are subjected only to the internal climatic conditions of heat, cold, shock, vibration, and humidity. Control motor tachometer generators larger than size 23 are not covered in this document.
Standard

Altitude Alerting Devices and Systems

2008-02-16
HISTORICAL
ARP1061A
This SAE Aerospace Recommended Practice (ARP) provides performance criteria for Altitude Alerting Devices and Systems. These devices can be self-contained or receive remote altitude information and can have integral or remote barometric corrections. Only the generation of the alerting signals is covered by this recommended practice and not the details of the visual or audio alerts operated by these signals. It is recommended that the system’s operational correspondence between the selected altitude settings of the Altitude Alerting Device and the Altitude Level Indication normally used to control the aircraft should not exceed ±250 ft RSS throughout the operating range of the device.
Standard

ALTITUDE ALERTING DEVICES AND SYSTEMS

1991-05-01
HISTORICAL
ARP1061
This ARP provides performance criteria for Altitude Alerting Devices and Systems. These devices can be self-contained or receive remote altitude information and can have integral or remote barometric corrections. Only the generation of the alerting signals is covered by this recommended practice and not the details of the visual or audio alerts operated by these signals. It is recommended that the system's operational correspondence between the selected altitude settings of the Altitude Alerting Device and the Altitude Level Indication normally used to control the aircraft should not exceed ±250 ft RSS throughout the operating range of the device.
Standard

Altitude Alerting Devices and Systems

2020-04-14
CURRENT
ARP1061B
This SAE Aerospace Recommended Practice (ARP) provides performance criteria for Altitude Alerting Devices and Systems. These devices can be self-contained or receive remote altitude information and can have integral or remote barometric corrections. Only the generation of the alerting signals is covered by this recommended practice and not the details of the visual or audio alerts operated by these signals. It is recommended that the system’s operational correspondence between the selected altitude settings of the Altitude Alerting Device and the Altitude Level Indication normally used to control the aircraft should not exceed ±250 ft RSS throughout the operating range of the device.
Standard

SYNCHROS

1959-11-15
HISTORICAL
ARP461A
This document is limited to units meeting the definitions of para. 1.3 and covers the following general class of synchros:
Standard

LIQUID OXYGEN QUANTITY INSTRUMENTS

1991-05-01
HISTORICAL
ARP433
This Aeronautical Recommended Practice covers Liquid Oxygen Quantity Indicators for use with associated Liquid Oxygen converters.
X