Refine Your Search

Search Results

Viewing 1 to 17 of 17
Standard

REPORTING CLEANLINESS LEVELS OF HYDRAULIC FLUIDS

1986-03-01
HISTORICAL
J1165_198603
This SAE Recommended Practice has been formulated to advance and endorse the use of the ISO (International Organization for Standardization) Solid Contaminant Code as the universal means for expressing the level of particulate contaminant in hydraulic fluid and for specifying acceptable limits of cleanliness. Worldwide approval was gained for this coding system because it provides a simple, unmistakable, meaningful, and consistent means of communication between suppliers and users. The code applies to all types of hydraulic (liquid) fluids used in fluid power and control systems as applied to self-propelled machines as referenced in J1116.
Standard

REPORTING CLEANLINESS LEVELS OF HYDRAULIC FLUIDS

1979-07-01
HISTORICAL
J1165_197907
This SAE Recommended Practice has been formulated to advance and endorse the use of the ISO (International Organization for Standardization) Solid Contaminant Code as the universal means for expressing the level of particulate contaminant in hydraulic fluid and for specifying acceptable limits of cleanliness. Worldwide approval was gained for this coding system because it provides a simple, unmistakable, meaningful, and consistent means of communication between suppliers and users. The code applies to all types of hydraulic (liquid) fluids used in fluid power and control systems.
Standard

Hydraulic Directional Control Valves, 3000 psi Maximum

2019-12-04
CURRENT
J748_201912
This SAE Recommended Practice has been set up by Subcommittee 4 of the Off-Road Machinery Technical Committee and is primarily for directional control valves on construction and industrial machinery equipment as referenced in SAE J1116. The purpose is to establish port area to flow relationship and match valve spool eye ends in relation to rated capacity. Port connections are optional for either the 4-bolt split flange connection or the internal straight thread "O" ring connection.
Standard

HYDRAULIC DIRECTIONAL CONTROL VALVES, 3000 PSI MAXIMUM

2008-05-20
HISTORICAL
J748_200805
This SAE Recommended Practice has been set up by Subcommittee 4 of the Off-Road Machinery Technical Committee and is primarily for directional control valves on construction and industrial machinery equipment as referenced in SAE J1116. The purpose is to establish port area to flow relationship and match valve spool eye ends in relation to rated capacity. Port connections are optional for either the 4-bolt split flange connection or the internal straight thread "O" ring connection.
Standard

HYDRAULIC DIRECTIONAL CONTROL VALVES, 3000 PSI MAXIMUM

1986-03-01
HISTORICAL
J748_198603
This SAE Recommended Practice has been set up by Subcommittee 4 of the Off-Road Machinery Technical Committee and is primarily for directional control valves on construction and industrial machinery equipment as referenced in SAE J1116. The purpose is to establish port area to flow relationship and match valve spool eye ends in relation to rated capacity. Port connections are optional for either the 4-bolt split flange connection or the internal straight thread "O" ring connection.
Standard

Hydraulic Power Pump Test Procedure

2019-11-20
CURRENT
J745_201911
This test code describes tests for determining characteristics of hydraulic positive displacement pumps used on off-road self-propelled work machines as referenced in SAE J1116.
Standard

Hydraulic Power Pump Test Procedure

2009-06-12
HISTORICAL
J745_200906
This test code describes tests for determining characteristics of hydraulic positive displacement pumps used on construction and industrial machinery as referenced in SAE J1116. These characteristics are to be recorded on data sheets similar to the ones shown in Figures 1 to 3. Two sets of data sheets are to be submitted: one at 49 °C (120 °F) and one at 82 °C (180 °F).
Standard

Hydraulic Power Pump Test Procedure

1996-09-01
HISTORICAL
J745_199609
This test code describes tests for determining characteristics of hydraulic positive displacement pumps used on construction and industrial machinery as referenced in SAE J1116. These characteristics are to be recorded on data sheets similar to the ones shown in Figures 1 to 3. Two sets of data sheets are to be submitted: one at 49 °C (120 °F) and one at 82 °C (180 °F).
Standard

HYDRAULIC POWER PUMP TEST PROCEDURE

1987-04-01
HISTORICAL
J745_198704
This test code describes tests for determining characteristics of hydraulic positive displacement pumps used on construction and industrial machinery as referenced in SAE J1116. These characteristics are to be recorded on data sheets similar to the ones shown herein. Two sets of data sheets are to be submitted: one at 49°C (120°F) and one at 82°C (180°F).
Standard

HYDRAULIC CONTROL VALVE TEST PROCEDURE

1986-03-01
HISTORICAL
J747_198603
This procedure describes laboratory tests for establishing operating characteristics of hydraulic directional control valves used on mobile industrial and construction equipment as referenced in SAE J1116. These characteristics are to be recorded on data sheets similar to those shown herein. Two sets of data are to be submitted--one at 122°F (50°C) and one at 194°F (90°C). A separate set of data sheets is to be submitted for the cylinder ports closest to, and farthest from the inlet and outlet ports of a multiple section valve.
Standard

Control Valve Test Procedure

1974-10-01
HISTORICAL
J747B_197410
This SAE Standard applies to hydraulic directional control valves as applied to self-propelled work machines referenced in SAE J1116. It describes a laboratory test procedure for evaluating: a.) Flow versus pressure drop, b.) Leakage rate, c.) Operating effort, d.) Metering characteristics versus spool travel, pilot pressure, or electrical current, e.) Relief valve characteristics. This document applies to single and multiple section hydraulic directional control valves. This document illustrates axial, manually operated valves although the test procedure is applicable to other input forms such as rotary actuation, electric current, hydraulic or pneumatic pressure.
Standard

ASSESSING CLEANLINESS OF HYDRAULIC FLUID POWER COMPONENTS AND SYSTEMS

1979-06-01
HISTORICAL
J1227_197906
To describe laboratory methods for determining and reporting the contaminant level of the wetted portion of hydraulic fluid power components, parts, subsystems and systems, and of fill fluids. For each type of item it provides a method of obtaining the liquid sample and the contamination level thereof. It also includes procedures for establishing a sampling plan and guidelines for establishing levels of acceptance, but does not set those levels.
Standard

ASSESSING CLEANLINESS OF HYDRAULIC FLUID POWER COMPONENTS AND SYSTEMS

1986-03-01
HISTORICAL
J1227_198603
To describe laboratory methods for determining and reporting the contaminant level of the wetted portion of hydraulic fluid power components, parts, subsystems and systems, and of fill fluids. For each type of item it provides a method of obtaining the liquid sample and the contamination level thereof. It also includes procedures for establishing a sampling plan and guidelines for establishing levels of acceptace, but does not set those levels.
Standard

Hydraulic Cylinder Integrity Test

2020-12-22
CURRENT
J1334_202012
Applies to hydraulic cylinders which are components of Off-Road Work Machines defined in SAE J1116.
X