TEMPERATURE CONTROL EQUIPMENT, AUTOMATIC AIRPLANE CABIN

1943-01-01
HISTORICAL
ARP89
These specifications are written to cover automatic temperature controls under three classifications, namely: A AUTOMATIC TEMPERATURE CONTROLS - GENERAL - Dealing with features applicable to all types and uses. B AUTOMATIC TEMPERATURE CONTROLS - MILITARY AND COMMERCIAL - Covering features applicable to military aircraft and commercial aircraft. C DESIRABLE DESIGN FEATURES - General information for use of those concerned in meeting the requirements contained herein.
Standard

Environmental Control Systems for Helicopters

2014-12-05
HISTORICAL
ARP292C
This ARP discusses design philosophy, system and equipment requirements, environmental conditions, and design considerations for helicopter environmental control systems (ECS). The helicopter ECS comprises that arrangement of equipment, controls, and indicators which supply and distribute dehumidified conditioned air for ventilation, cooling and heating of the occupied compartments, and cooling of the avionics. The principal features of the system are: a A controlled fresh air supply b A means for cooling (air or vapor cycle units and heat exchangers) c A means for removing excess moisture from the air supply d A means for heating e A temperature control system f A conditioned air distribution system The ARP is applicable to both civil and military helicopters where an ECS is specified; however, certain requirements peculiar to military applications, such as nuclear, biological and chemical (NBC) protection, are not covered.
Standard

Environmental Control for Civil Supersonic Transport

2011-08-10
CURRENT
AIR746C
This document supplements ARP85, to extend its use in the design of ECS for supersonic transports. The ECS provides an environment controlled within specified operational limits of comfort and safety, for humans, animals, and equipment. These limits include pressure, temperature, humidity, conditioned air velocity, ventilation rate, thermal radiation, wall temperature, audible noise, vibration, and composition (ozone, contaminants, etc.) of the environment. The ECS is comprised of equipment, controls, and indicators that supply and distribute conditioned air to the occupied compartments. This system is defined within the ATA 100 specification, Chapter 21. It interfaces with the pneumatic system (Chapter 36 of ATA 100), at the inlet of the air conditioning system shutoff valves.
Standard

Environmental Control for Civil Supersonic Transport

2006-06-28
HISTORICAL
AIR746B
This document supplements ARP85, to extend its use in the design of ECS for supersonic transports. The ECS provides an environment controlled within specified operational limits of comfort and safety, for humans, animals, and equipment. These limits include pressure, temperature, humidity, conditioned air velocity, ventilation rate, thermal radiation, wall temperature, audible noise, vibration, and composition (ozone, contaminants, etc.) of the environment. The ECS is comprised of equipment, controls, and indicators that supply and distribute conditioned air to the occupied compartments. This system is defined within the ATA 100 specification, Chapter 21. It interfaces with the pneumatic system (Chapter 36 of ATA 100), at the inlet of the air conditioning system shutoff valves.
Standard

HEAT TRANSFER PROBLEMS ASSOCIATED WITH AEROSPACE VEHICLES

1978-04-01
CURRENT
AIR732
The discipline of heat transfer concerns itself basically with the three modes of transferring thermal energy (convection, conduction, and radiation) and their inter-relations. In any phase of aerospace vehicle design, the importance of any of these basic modes will vary depending upon the natural and induced environment the mission imposes as well as the vehicle configuration.
Standard

Spacecraft Equipment Environmental Control

2006-03-24
HISTORICAL
AIR1168/13
This part of the manual presents methods for arriving at a solution to the problem of spacecraft inflight equipment environmental control. The temperature aspect of this problem may be defined as the maintenance of a proper balance and integration of the following thermal loads: equipment-generated, personnel-generated, and transmission through external boundary. Achievement of such a thermal energy balance involves the investigation of three specific areas: 1 Establishment of design requirements. 2 Evaluation of properties of materials. 3 Development of analytical approach. The solution to the problem of vehicle and/or equipment pressurization, which is the second half of major environmental control functions, is also treated in this section. Pressurization in this case may be defined as the task associated with the storage and control of a pressurizing fluid, leakage control, and repressurization.
Standard

Spacecraft Equipment Environmental Control

2011-07-25
CURRENT
AIR1168/13A
This part of the manual presents methods for arriving at a solution to the problem of spacecraft inflight equipment environmental control. The temperature aspect of this problem may be defined as the maintenance of a proper balance and integration of the following thermal loads: equipment-generated, personnel-generated, and transmission through external boundary. Achievement of such a thermal energy balance involves the investigation of three specific areas: 1 Establishment of design requirements. 2 Evaluation of properties of materials. 3 Development of analytical approach. The solution to the problem of vehicle and/or equipment pressurization, which is the second half of major environmental control functions, is also treated in this section. Pressurization in this case may be defined as the task associated with the storage and control of a pressurizing fluid, leakage control, and repressurization.
Standard

Environmental Control System Contamination

2003-10-31
HISTORICAL
AIR1539A
This publication will be limited to a discussion of liquid and particulate contaminants which enter the aircraft through the environmental control system (ECS). Gaseous contaminants such as ozone, fuel vapors, sulphates, etc., are not covered in this AIR. It will cover all contamination sources which interface with ECS, and the effects of this contamination on equipment. Methods of control will be limited to the equipment and interfacing ducting which normally falls within the responsibility of the ECS designer.
Standard

ENVIRONMENTAL CONTROL SYSTEM CONTAMINATION

1981-01-30
HISTORICAL
AIR1539
This publication will be limited to a discussion of liquid and particulate contaminants which enter the aircraft through the environmental control system (ECS). Gaseous contaminants such as ozone, fuel vapors, sulphates, etc., are not covered in this AIR. It will cover all contamination sources which interface with ECS, and the effects of this contamination on equipment. Methods of control will be limited to the equipment and interfacing ducting which normally falls within the responsiblity of the ECS designer.
Standard

Heat Sinks for Airborne Vehicles

2021-12-15
CURRENT
AIR1957A
This document summarizes types of heat sinks and considerations in relation to the general requirements of aircraft heat sources, and it provides information to achieve efficient utilization and management of these heat sinks. In this document, a heat sink is defined as a body or substance used for removal of the heat generated by thermodynamic processes. This document provides general data about airborne heat sources, heat sinks, and modes of heat transfer. The document also discusses approaches to control the use of heat sinks and techniques for analysis and verification of heat sink management. The heat sinks are for aircraft operating at subsonic and supersonic speeds.
Standard

LIQUID COOLING SYSTEMS

1985-09-01
HISTORICAL
AIR1811
This publication is applicable to liquid cooling systems of the closed loop type and the expendable coolant type in which the primary function is transporting of heat from its source to a heat sink. Most liquid cooling system applications are oriented toward the cooling of electronics. Liquid cooling techniques, heat sinks, design features, selection of coolants, corrosion control, and servicing requirements for these systems are presented. Information on vapor compression refrigeration systems, which are a type of cooling system, is found in Reference 1.
Standard

Liquid Cooling Systems

2015-10-16
CURRENT
AIR1811A
This publication is applicable to liquid cooling systems of the closed loop type and the expendable coolant type in which the primary function is transporting of heat from its source to a heat sink. Most liquid cooling system applications are oriented toward the cooling of electronics. Liquid cooling techniques, heat sinks, design features, selection of coolants, corrosion control, and servicing requirements for these systems are presented. Information on vapor compression refrigeration systems, which are a type of cooling system, is found in Reference 1.
Standard

Thermophysical Properties of the Natural Environment, Gases, Liquids, and Solids

2004-06-22
HISTORICAL
AIR1168/9
This AIR is arranged in the following four sections: 2A - Properties of the Natural Environment 2B - Properties of Gases 2C - Properties of Liquids 2D - Properties of Solids A summary of each section is given below. Section 2A - This section includes currently applicable earth atmosphere standards (Refs. 101 and 103) and data on the near-Earth environment. Limited data on Mars and Venus reflected solar and planetary-emitted radiation and on micrometeorite data are also included. For space vehicle applications, environmental models are of two general types: orbital and reentry. For orbital models, variable properties such as time and solar flux are usually averaged. Reentry atmospheres are chiefly a function of location and altitude, and selection may be based on reentry location. Variation with latitude is an important local effect (Ref. 106). The electromagnetic solar radiation data in this section are for altitudes above the Earth’s atmosphere.