The purpose of this document is to provide minimum requirements for cleaning aircraft breathing oxygen systems and components, inspection methods and packaging after cleaning, and guidelines for oxygen equipment cleaning areas.
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
This standard is designed to cover all types of pressure reducers required for oxygen systems and for all performance profiles without regard for a particular inlet pressure or outlet pressure performance curve. Special attention will be given, however, to construction requirements essential in reducers where critical high initial oxygen pressures such as 1850 to 2250 psig (12.76 to 15.51 MN/m2 gauge) at 70° F (21.1° C) are involved.
This specification applies to a chemical oxygen generator assembly for the following uses: a First aid treatment of passenger cabin occupants after emergency descent in a turbine engine powered airplane with pressurized cabin, as specified in FAR 121.333, Para. e (3). b By cabin attendants to maintain their mobility after cabin decompression.
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
This SAE AEROSPACE Standard (AS) covers all types of manually operated high pressure Oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft.
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
The scope of this document is to provide a guideline for the preparation of a plan for testing of inservice chemical oxygen generators to confirm their design useful life. The test program should also allow determination with a sufficient level of confidence, whether generators are suitable for further use (i.e., life extension, or if the useful life limit has been reached).
This document provides recommended guidelines for a comprehensive program to determine the useful life of chemical oxygen generators where useful life is defined as the sum of shelf and service life. Further, this document provides for a test program to determine with a sufficient level of confidence if the generators are suitable for further use and/or if the life limit has been reached. This program should include testing of generators of a representative sampling of a given year's production, of a particular part number, to provide a level of confidence sufficient to permit the units to be used for an additional specified time period.
The scope of this document is to provide a guideline for the preparation of a plan for testing of inservice chemical oxygen generators to confirm their design useful life. The test program should also allow determination with a sufficient level of confidence, whether generators are suitable for further use (i.e., life extension, or if the useful life limit has been reached).
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
This AS covers oxygen filler valves for use in aircraft to ensure safe servicing of high pressure oxygen system cylinders. The intent is that the valve shall automatically control the rate of fill such that the temperature rise in the oxygen system caused by compression heating of the gas will be within acceptable limits. In addition, the valve shall have a pressure sensitive closing valve to automatically control the final pressure for a correct amount of oxygen in the system cylinder. The pressure closing level may be manually selected by means of adjustment dials on the valve.