Refine Your Search

Topic

Search Results

Standard

SECONDARY FILTERS FOR FLUID SYSTEM RELIABILITY

1994-05-01
HISTORICAL
AIR4057
It discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2004-12-01
HISTORICAL
AIR4057A
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2012-09-24
CURRENT
AIR4057B
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

FINE WIRE MESH FOR FILTER ELEMENTS

1989-05-30
HISTORICAL
AIR888A
This AIR discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication, fuel systems and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

RECOMMENDED STANDARD FOR AEROSPACE FILTER ELEMENT FINE WIRE MESH

2011-02-11
HISTORICAL
AIR888
This AIR discusses the nature, method of manufacture and chemistry of fine wire meshes of the type used for filtration and similar applications, and how this information may be utilized in setting up a quality control program to insure reliability of meshes used for such applications.
Standard

Fine Wire Mesh for Filter Elements

2002-11-14
HISTORICAL
AIR888B
This SAE Aerospace Information Report (AIR) discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication fuel systems, and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

Fine Wire Mesh for Filter Elements

2012-09-24
CURRENT
AIR888C
This SAE Aerospace Information Report (AIR) discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication fuel systems, and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

Procedure for the Determination of Particulate Contamination of Air in Dust Controlled Spaces by the Manual Particle Count Method

2001-03-01
HISTORICAL
ARP743B
This SAE Aerospace Recommended Practice (ARP) describes two procedures for sampling particles in dust controlled spaces. One procedure covers airborne dust above 5 μm. The other (and newly added procedure) covers particles of 25 μm and larger that “fall out” of the environment onto surfaces. In each case the particles are sized in the longest dimension and counted. Airborne particles are reported as particles per cubic meter (cubic foot) whereas particles collected in fall out samples are reported as particles per 0.1 square meter (square foot). This document includes English units in parentheses as referenced information to the SI units where meaningful. These procedures may also be used for environmental analysis where the quality of the particles by visual or chemical analysis is intended.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2002-05-21
HISTORICAL
ARP599C
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

AEROSPACE - DYNAMIC TEST METHOD FOR DETERMINING THE RELATIVE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599B
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Evaluation of Particulate Contamination in Hydraulic Fluid - Membrane Procedure

2018-08-13
CURRENT
ARP4285A
This SAE Aerospace Recommended Practice (ARP) establishes a method for evaluating the particulate matter extracted from the working fluid of a hydraulic system or component using a membrane. The amount of particulate matter deposited on the membrane due to filtering a given quantity of fluid is visually compared against a standard membrane in order to provide an indication of the cleanliness level of the fluid.
Standard

Aerospace - Evaluation of Particulate Contamination in Hydraulic Fluid - Membrane Procedure

2008-06-04
HISTORICAL
ARP4285
This SAE Aerospace Recommended Practice (ARP) establishes a method for evaluating the particulate matter extracted from the working fluid of a hydraulic system or component using a membrane. The amount of particulate matter deposited on the membrane due to filtering a given quantity of fluid is visually compared against a standard membrane in order to provide an indication of the cleanliness level of the fluid. A particular feature of this method is the membrane preparation to achieve an even particulate distribution on the membrane suitable for other applications. Membrane evaluation using standard membranes, described in this document, is an alternative technique to counting with either an optical microscope (ARP598) or an automatic particle counter (ISO 11500). The latter particle counting procedures are considered more precise.
Standard

Aerospace Hydraulic Fluids Physical Properties

2016-11-01
HISTORICAL
AIR1362C
This SAE Aerospace Information Report (AIR) presents data on hydraulic fluids which are of interest to detail designers of hydraulic systems and components for aerospace flight vehicles. The data pertains to fluids conforming to the following specifications: MIL-PRF-5606 MIL-H-8446 MIL-PRF-27601 (canceled) MIL-PRF-27601 has been canceled without replacement and the data presented herein is for information purposes only. MIL-PRF-83282 MIL-H-53119 MIL-PRF-87257 AS1241 Type IV, Classes 1 and 2, and Type V
Standard

Aerospace Hydraulic Fluids Physical Properties

2018-08-16
CURRENT
AIR1362D
This SAE Aerospace Information Report (AIR) presents data on hydraulic fluids which are of interest to detail designers of hydraulic systems and components for aerospace flight vehicles. The data pertains to fluids conforming to the following specifications: MIL-PRF-5606 MIL-H-8446 MIL-PRF-27601 (canceled) MIL-PRF-27601 has been canceled without replacement and the data presented herein is for information purposes only. MIL-PRF-83282 MIL-H-53119 MIL-PRF-87257 AS1241 Type IV, Classes 1 and 2, and Type V
X