Refine Your Search

Search Results

Viewing 1 to 3 of 3
Technical Paper

Steady State Characterization of Arcing in 540 V dc Distribution Systems

2017-09-19
2017-01-2035
As applications in aerospace, transportation and data centers are faced with increased electric power consumption, their dc operating voltages have increased to reduce cable weight and to improve efficiency. Electric arcs in these systems still cause dangerous fault conditions and have garnered more attention in recent years. Arcs can be classified as either low impedance or high impedance arcs and both can cause insulation damage and fires. Low impedance arcs release lots of energy when high voltage becomes nearly shorted to ground. High impedance arcs can occur when two current-carrying electrodes are separated, either by vibration of a loose connection or by cables snapping. The high impedance arc decreases load current due to a higher equivalent load impedance seen by the source. This complicates the differentiation of a high impedance arc fault from normal operation.
Technical Paper

Modeling and Simulation of Power Loss in Drive Unit of Electromechanical Actuator

2012-10-22
2012-01-2232
In all-electric aircraft, electromechanical actuators (EMAs) will be used to replace hydraulic actuators. Due to the highly transient mission profiles of the aircraft operation, thermal management of EMAs is a significant issue. In this paper, we study the heat problem of the control and drive units of EMAs, and build a model to calculate and simulate the power loss and heat generation in the driver board. The driver unit consists of a power inverter, a capacitor, a power dissipating resistor and a control circuit. The power loss of each component is studied. The heat loss in the power inverter comes mainly from the power switches: IGBTs. The on-state loss is proportional to the current of the motor, and the switching loss is determined by the switching frequency as well as current.
Technical Paper

A Reduced-Order Model for Electromechanical Actuator

2012-10-22
2012-01-2230
In the aviation community, there is a high priority to develop all-electric aircraft. Electro-mechanical actuation systems would replace traditional, large, heavy and difficult-to-maintain hydraulic actuation systems. This movement from hydraulic actuation to electrical actuation enhances the flexibility to integrate redundancy and emergency system in future military aircraft. Elimination of the hydraulic fluid removes the possibility of leakage of corrosive hydraulic fluid and the associated fire hazard, as well as environmental concerns. The switch from hydraulic to electrical actuation provides additional benefits in reduced aircraft weight, improved survivability and improved maintainability. The heat load in an electro-mechanical actuation (EMA) is highly transient and localized in nature; therefore a phase change material could be embedded in the heat generating components to store peak heat load.