Technical Paper

Chemical Analysis of Potable Water and Humidity Condensate Collected During the MIR-21 Mission

1997-07-01
972462
The primary source of potable water planned for the International Space Station will be generated from the reclamation of humidity condensate, urine, and hygiene waters. It is vital to crew health and performance that this reclaimed water be safe for human consumption, and that health risks associated with recycled water consumption be identified and quantified. Only recently has data been available on the chemical constituents in reclaimed waters generated in microgravity. Results for samples collected during Mir-21 reveal that both the reclaimed water and stored water are of potable quality, although the samples did not meet U.S. standards for total organic carbon (TOC), total phenols, and turbidity.
Technical Paper

The State of ISS ATCS Design, Assembly and Operation

2003-07-07
2003-01-2513
The International Space Station (ISS) Active Thermal Control System (ATCS) (Ref. 1,2) has changed over the past several years to address problems and to improve its assembly and operation on-orbit. This paper captures the ways in which the Internal (I) ATCS and External (E) ATCS have changed design characteristics and operations both for the system currently operating on-orbit and the new elements of the system that are about to be added and/or activated. The rationale for changes in ATCS design, assembly and operation will provide insights into the lessons learned during ATCS development. The state of the assembly of the integrated ATCS will be presented to provide a status of the build-up of the system. The capabilities of the on-orbit system will be presented with a summary of the elements of the ISS ATCS that are functional on-orbit plus the plans for launch of remaining parts of the integrated ISS ATCS.
Technical Paper

An Automated Oxygen Diffusion Measurement System for Porous Media in Microgravity

2003-07-07
2003-01-2612
Liquid and gas exchange within a particulate plant-rooting medium is likely to be altered in a microgravity environment. A difference in gravitational force can result in significant offsets in control parameters developed on earth for optimum plant growth, due to the shift in hydrostatic water distribution. The experiment being developed will examine the effects of variable gravity on water distribution and gas diffusion. We are developing and testing an automated gas diffusion measurement system for use on the International Space Station (ISS). To allow comparison of μg and 1g conditions, gas diffusion cell designs were horizontally oriented to minimize gravitational effects using 1) a ‘thin rectangular profile’ cell and 2) a cylindrical cell design for flight. Electronic solenoid valves provide air and water flow control while pressure transducers measure water and substrate potential.
Technical Paper

Phase VI Advanced EVA Glove Development and Certification for the International Space Station

2001-07-09
2001-01-2163
Since the early 1980’s, the Shuttle Extra Vehicular Activity (EVA) glove design has evolved to meet the challenge of space based tasks. These tasks have typically been satellite retrieval and repair or EVA based flight experiments. With the start of the International Space Station (ISS) assembly, the number of EVA based missions is increasing far beyond what has been required in the past; this has commonly been referred to as the “Wall of EVA’s”. To meet this challenge, it was determined that the evolution of the current glove design would not meet future mission objectives. Instead, a revolution in glove design was needed to create a high performance tool that would effectively increase crewmember mission efficiency. The results of this effort have led to the design, certification and implementation of the Phase VI EVA glove into the Shuttle flight program.
Technical Paper

Shuttle Extravehicular Mobility Unit (EMU) Operational Enhancements

1990-07-01
901317
The NASA/Industry Shuttle EMU team initiated an EMU program activity in 1988 to reduce EMU criticality 1 failure causes, reduce ground operations costs, and also to enhance on-orbit operational Extravehicular Activity (EVA) capability. Replacement/refurbishment hardware is being developed, certified, and delivered. System level life extention testing is expected to extend the Life Limited Components replacement schedule. Goals of this program are to achieve a 25 percent reduction in ground turn-around man-hours and processing time between missions and to extend Extravehicular Activity (EVA) on-orbit capabilities expected to be necessary to support Space Station Freedom assembly and contingency EVA operations. This paper identifies and describes tasks being implemented with expected benefits to NASA-manned spaceflight programs.
Technical Paper

Benefits of an EMU Glove Active Heating System

1995-07-01
951549
Recent Shuttle extravehicular activity (EVA) missions have shown the need for improved thermal performance in Space Suit Assembly (SSA) gloves to successfully complete assembly of the International Space Station (ISS). Passive thermal design improvements have been successfully incorporated, however, additional improvements are still possible. An Active Heated Glove Assembly was developed to aid in the prevention of cold hands and fingers during periods of rest and low metabolic activity. Environmental vacuum tests have shown that the system accomplishes its goals and measurably increases glove thermal performance.
Technical Paper

Collection and Chemical Analysis of Reclaimed Water and Condensate from the Mir Space Station

1996-07-01
961569
Potable- and hygiene-quality water will be supplied to crews on the International Space Station through the recovery and purification of spacecraft wastewaters, including humidity condensate, urine, and wash water. Contaminants released into the cabin air from human metabolism, hardware offgassing, flight experiments, and routine operations will be present in spacecraft humidity condensate; normal constituents of urine and bathing water will be present in urine and untreated wash water. This report describes results from detailed analyses of Mir reclaimed potable water, ground-supplied water, and humidity condensate. These results are being used to develop and test water recycling and monitoring systems for the International Space Station (ISS); to evaluate the efficiency of the Mir water processors; and to determine the potability of the recycled water on board.
Technical Paper

Recent Advances in the Development of Spacesuit Gloves

1996-07-01
961424
The continuous development of Extravehicular Activity (EVA) spacesuit gloves has lead to an effective solution for performing EVA to date. Some aspects of the current EVA gloves have been noted to affect crew performance in the form of limited dexterity and accelerated onset of fatigue from high torque mobility joints. This in conjunction with the fact that more frequent and complex EVAs will occur with the fabrication and occupation of Space Station Freedom, suggest the need for improved spacesuit gloves. Therefore, several efforts have been conducted in the recent past to enhance the performance of the spacesuit glove. The following is a description of the work performed in these programs and their impact on the design and performance of EVA equipment. In the late 1980's and early 1990's, a spacesuit glove design was developed that focused on building a more conformal glove with improved mobility joints that could function well at a higher operating pressure.
Technical Paper

Comparison of Shortened and Standard Liquid Cooling Garments to Provide Physiological and Subjective Comfort During EVA

2004-07-19
2004-01-2347
The shortened liquid cooling/warming garment (SLCWG) developed by the University of Minnesota group was compared with the standard NASA liquid cooling/ventilating garment (LCVG) garment during physical exertion in comfort (24°C) and hot (35°C) chamber environments. In both environmental conditions, the SLCWG was just as effective as the LCVG in maintaining rectal temperature (Tre) in a thermal comfort range; sweat production on the face was less; and subjective perception of overall and local body comfort was higher. The findings indicate that the SLCWG produces the same or greater comfort level as that achieved with the LCVG's total coverage of the body surface.