Particle Size Distribution from a Heavy-Duty Diesel Engine: Steady-State and Transient Emission Measurement Using Two Dilution Systems and Two Fuels

2003-03-03
2003-01-0285
Particle size distribution and number concentration were measured in the dilute exhaust of a heavy-duty diesel engine for steady-state and transient engine operation using two different dilution systems that included a full flow CVS that was coupled to an ejector pump (CVS-EP), and a double-ejector micro-dilution tunnel (DEMDT) that was connected to engine exhaust close to turbocharger outlet. Measurements were performed using a scanning mobility particle sizer (SMPS), an electrical low pressure impactor (ELPI), and a parallel flow diffusion battery (PFDB). Fuels with sulfur content of about 385 ppm and 1 ppm were used for this work. The PFDB performed well in measuring nanoparticles in the size range below 56 nm when compared with the SMPS. This was especially valid when a distinct log-normal size distribution in the size range below 56 nm in diameter, the upper size limit of the PFDB, was present.