Refine Your Search

Search Results

Viewing 1 to 2 of 2
Technical Paper

Temperature Control of Water with Heating, Cooling and Mixing in a Process with Recycle Loop

2014-04-01
2014-01-0652
A hot and cold water mixing process with a steam condenser and a chilled water heat exchanger is set up for an engine EGR fouling test. The test rig has water recycled in the loop of a pump, heat exchangers, a three-way mixing valve, and a test EGR unit. The target unit temperature is controlled by a heating, cooling and mixing process with individual valves regulating the flow-rate of saturated steam, chilled water and mixing ratio. The challenges in control design are the dead-time, interaction, nonlinearity and multivariable characteristics of heat exchangers, plus the flow recycle in the system. A systems method is applied to extract a simple linear model for control design. The method avoids the nonlinearity and interaction among different temperatures at inlet, outlet and flow-rate. The test data proves the effectiveness of systems analysis and modeling methodology. As a result, the first-order linear model facilitates the controller design.
Technical Paper

A Hardware-in-the-Loop (HIL) Bench Test of a GT-Power Fast Running Model for Rapid Control Prototyping (RCP) Verification

2016-04-05
2016-01-0549
A GT-Power Fast Run Model simplified from detail model for HIL is verified with a bench test using the dSPACE Simulator. Firstly, the conversion process from a detailed model to FRM model is briefly described. Then, the spark timing, fuel pulse with control for FAR, and torque level control are developed for proof of concept. Moreover a series of FRM/Simulink co-simulation and HIL tests are conducted. In the summary, the test results are presented and compared with GT detailed model simulations. The test results show that the FRM/dSPACE HIL stays consistent in most variables of interest under 0.7-0.9 real-time factor condition between 1000 - 5000 RPM. The same steady-state can be reached by RCP controllers or with GT-Power internal controllers. The transient states are close using different control algorithm. The main purpose of HIL application is achieved, despite inconsistencies in performance data like fuel consumption.
X