Suppression of Sulfide Emission During Lean Nox Trap Desulfation
2001-03-05
2001-01-1299
Lean NOx traps are being extensively examined (Ref. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12) because they can be efficiently used to reduce the NOx emissions from port fuel injected and direct fuel injected spark ignited gasoline engines. A lean NOx trap (LNT) stores NOx during lean A/F engine operation. However, its storage capacity is limited and the LNT must be regenerated periodically by subjecting the LNT to momentary rich A/F operation for several seconds. The regeneration process releases the NOx that is chemically bonded to the washcoat and subsequently reduces it to N2 and O2. Fuel that contains a non-zero amount of sulfur will contaminate an LNT by significantly reducing its NOx storage capacity. Therefore, except for the case of a zero level of sulfur in the fuel, the LNT must be desulfated on a periodic basis. The desulfation process requires that the temperature of the LNT be raised to a temperature of about 650°C for several minutes.