A Solid Particle Counting System (SPCS) has been developed according to the ECE draft regulation proposed by the particle measurement program (PMP). In the previous report the basic performance of the SPCS has been mentioned in detail [1, 2, 3, 4, 5 and 6]. It has been reported that the SPCS demonstrates very stable dilution of sample with air and the error of real time dilution factor is less than 6% up to the total dilution factor of 1000. Penetration of solid particles through the SPCS is over 95% and volatile particles removal efficiency is over 99%. In this study the SPCS has been used to investigate the soot emission behavior from different vehicles with different after-treatment technologies. Direct injection (DI) diesel vehicles without diesel particulate filter (DPF), and with different DPFs (catalyzed and non-catalyzed) have been tested. Direct injection gasoline (DIG) vehicle with oxidation and NOx reduction catalysts have also been tested.