Methods for Determining Pediatric Thoracic Force-Deflection Characteristics From Cardiopulmonary Resuscitation

2008-11-03
2008-22-0004
Accurate pediatric thoracic force and deflection data are critical to develop biofidelic pediatric anthropomorphic test devices (ATDs) used in designing motor vehicle safety systems for child occupants. Typically, postmortem human subject (PMHS) experiments are conducted to gather such data. However, there are few pediatric PMHS available for impact research; therefore, novel methods are required to determine pediatric biomechanical data from children. In this study, we have leveraged the application of chest compressions provided in the clinical environment during pediatric cardiopulmonary resuscitation (CPR) to collect this fundamental data. The maximum deflection of the chest during CPR is in the range of chest deflections in PMHS impact experiments and therefore CPR exercises the chest in ways that are meaningful for biofidelity assessment. Thus, the goal of this study was to measure the force-deflection characteristics of the thorax of children and young adults during CPR.