Refine Your Search

Search Results

Viewing 1 to 4 of 4
Technical Paper

Systematic Approach to Mitigate Urea Tank Sloshing Noise in Passenger Vehicles

2024-01-16
2024-26-0200
In the current era, vehicle manufacturers focus has increased towards passenger comfort and one of the key areas is NVH. Vehicle level NVH targets are cascaded to component level for obtaining better refinement in cabin. One such performance attribute is sloshing noise of urea in diesel vehicles. Migration from BS4 to BS6.2 norms demand complex technological changes to automobile manufacturers to add extra components to the vehicles which is a big challenge in identifying the locations at critical stage of the project phase. In one of the developments of mid SUV category vehicle, sloshing noise from urea tank is perceived as objectionable during low-speed braking and while passing over speed breakers. This paper addresses the measurement conditions of sloshing noise and its evaluation procedure to quantify the sloshing noise at vehicle level. The sloshing noise is perceived in the frequency band of 50 to 1000 Hz.
Technical Paper

NVH Refinement of Structure-Borne Tonal Noise in Electric Vehicle

2024-01-16
2024-26-0198
Globally all OEMs are moving towards electric vehicle to reduce emission and fuel cost. Customers expect highest level of refinement and sophistication in electric vehicle. At present, the customers are sensitive to high pitched tonal noise produced by electric powertrain which gives a lot of challenges to NVH engineers to arrive at a cost-effective solution in less span of time. Higher structure borne tonal noise is perceived in electric vehicle at the vehicle speeds of ~ 28 kmph, 45 kmph and 85 kmph. The test vehicle is front wheel drive compact SUV powered by motor in the front. The electric drive unit is connected to cradle and subframe with help of three mounts. Transfer path analysis (TPA) using blocked forces method is carried out to identify the exact forces of the electric drive unit entering the mounts. Powertrain mount is characterized by applying the predicted forces and dynamic stiffness at problematic frequency is measured.
Technical Paper

Countermeasures for Low Frequency Boom Noise Reduction in Electric Vehicle

2024-01-16
2024-26-0214
Electric vehicles (EV) are much quieter than IC engine powered vehicles due to less mechanical components and absence of combustion. The lower cabin noise in electric vehicles make customers sensitive to even small noise disturbances in vehicle. Road boom noise is one of such major concerns to which the customers are sensitive in electric vehicles. The test vehicle is a front wheel driven compact SUV powered by electric motor. On normal plain road, noise levels are acceptable but when the vehicle has been driven on coarse road, the boom noise is perceived, and the levels are objectionable. Multi reference Transfer Path Analysis (MTPA) is conducted to identify the path through which maximum forces are entering the body. Based on MTPA, modifications are proposed on the suspension bushes and the noise levels were assessed.
Technical Paper

HVAC NVH Refinement in Electric Vehicle

2024-01-16
2024-26-0206
Customers expect more advanced features and comfort in electric vehicles. It is challenging for NVH engineers to reduce the vibration levels to a great extent in the vehicle without adding cost and weight. This paper focuses on reducing the tactile vibration in electric vehicle when AC is switched ON. Vibration levels were not acceptable and modulating in nature on the test vehicle. Electric compressor is used for cabin cooling and battery cooling in the vehicle. Compressor is connected to body with the help of isolators. Depending upon cooling load, the compressor operates between 1000 rpm and 8000 rpm. The 1st order vibration of compressor was dominant on tactile locations at all the compressor speeds. Vibration levels on steering wheel were improved by 10 dB on reducing the dynamic stiffness of isolators. To reduce the transfer of compressor vibration further, isolators are provided on HVAC line connection on body and mufflers are provided in suction and discharge line.
X