Refine Your Search

Search Results

Journal Article

Numerical Modelling of Coolant Filling and De-aeration in a Battery Electric Vehicle Cooling System

2022-03-29
2022-01-0775
Trapped air bubbles inside coolant systems have adverse effect on the cooling performance. Hence, it is imperative to ensure an effective filling and de-aeration of the coolant system in order to have less air left before the operation of the coolant system. In the present work, a coolant/air multiphase VOF method was utilized using the commercial CFD software SimericsMP+® to study the coolant filling and subsequent de-aeration process in a Battery Electric Vehicle (BEV) cooling system. First, validations of the numerical simulations against experiments were performed for a simplified coolant recirculation system. This system uses a tequila bottle for de-aeration and the validations were performed for different coolant flow rates to examine the de-aeration efficiency. A similar trend of de-aeration was captured between simulation and experimental measurement.
X