Refine Your Search

Search Results

Viewing 1 to 2 of 2
Technical Paper

Intentional Failure of a 5000 psig Hydrogen Cylinder Installed in an SUV Without Standard Required Safety Devices

2007-04-16
2007-01-0431
A vehicle's gasoline fuel tank was removed and replaced with a 5,000-psig, Type-III, aluminum-lined hydrogen cylinder. High-pressure cylinders are typically installed with a thermally-activated pressure relief device (PRD) designed to safely vent the contents of the cylinder in the event of accidental exposure to fire. The objective of this research was to assess the results of a catastrophic failure in the event that a PRD were ineffective. Therefore, no PRD was installed on the vehicle to ensure cylinder failure would occur. The cylinder was pressurized and exposed to a propane bonfire in order to simulate the occurrence of a gasoline pool fire on the underside of the vehicle. Measurements included temperature and carbon monoxide concentration inside the passenger compartment of the vehicle to evaluate tenability. Measurements on the exterior of the vehicle included blast wave pressures. Documentation included standard, infrared, and high-speed video.
Technical Paper

Hydrogen Fuel Tank Fire Exposure Burst Test

2005-04-11
2005-01-1886
A fire exposure test was conducted on a 72.4 liter composite (Type HGV-4) hydrogen fuel tank at an initial hydrogen pressure of 34.3 MPa (ca 5000 psi). No Pressure Relief Device was installed on the tank to ensure catastrophic failure for analysis. The cylinder ruptured at 35.7 MPa after a 370 kW fire exposure for 6 min 27 seconds. Blast wave pressures measured along a line perpendicular to the cylinder axis were 18% to 25% less the values calculated from ideal blast wave correlations using a blast energy of 13.4 MJ, which is based on the ideal gas internal energy at the 35.7 MPa burst pressure. The resulting hydrogen fireball maximum diameter of 7.7 m is about 19% less than the value predicted from existing correlations using the 1.64 kg hydrogen mass in the tank.
X