Sampling System for Solid and Volatile Exhaust Particle Size, Number, and Mass Emissions

2007-04-16
2007-01-0307
A solid particle sampling system (SPSS) that is equipped with a heated oxidation catalyst, micro-dilution tunnels, filter holders and sampling probes, was designed and developed to collect filter-based solid and total (solid plus volatile) particles from the exhaust of internal combustion engines, and to facilitate the measurement of solid and total particles when equipped with particle measuring instruments for size, number, mass, and other particle characteristics. The SPSS was characterized with laboratory aerosol and showed a very low solid particle loss of less than 5 percent using sodium chloride particles, very high volatile particle removal of better than 98 percent using oil droplets, and no formation of sulfuric acid particles when using ammonium sulfate particles. The SPSS is a useful tool for researchers interested in characterizing the solid and volatile fraction of particles emitted from combustion sources.