METABOLIC SIMULATOR TESTING SYSTEMS FOR AVIATION BREATHING EQUIPMENT

1991-04-01
ARP4259
This Aerospace Recommended Practice (ARP) describes test equipment and methods used for testing closed cycle or semi closed cycle breathing devices of short duration that are designed to operate with a high partial pressure of oxygen in the breathing circuit. It is intended to supplement ARP1109 and ARP1398 for applications involving closed cycle or semiclosed cycle breathing equipment which may be evaluated to the requirements of AS8031 and/or AS8047.
Standard

Metabolic Simulator Testing Systems for Aviation Breathing Equipment

2021-08-11
ARP4259A
This Aerospace Recommended Practice (ARP) describes test equipment and methods used for testing closed cycle or semiclosed cycle breathing devices of short duration that are designed to operate with a high partial pressure of oxygen in the breathing circuit. It is intended to supplement ARP1109 and ARP1398 for applications involving closed cycle or semiclosed cycle breathing equipment which may be evaluated to the requirements of AS8031 and/or AS8047.
Standard

Cleaning Methods and Procedures for Breathing Oxygen Equipment

1999-05-01
AS13591
The purpose of this document is to provide minimum requirements for cleaning aircraft breathing oxygen systems and components, inspection methods and packaging after cleaning, and guidelines for oxygen equipment cleaning areas.
Standard

Oxygen Considerations for High Elevation Airport Operations (HEAO)

2021-08-26
AIR6829
This document covers information concerning the use of oxygen when flying into and out of high elevation airports for both pressurized and non-pressurized aircraft. Oxygen requirements for pressurized aircraft operating at high altitudes have for decades emphasized the potential failures that could lead to a loss of cabin pressurization coupled with the potential severe hypoxic hazard that decompressions represent. This document is intended to address the case where the relationship between cabin and ambient pressures are complicated by operations at high terrestrial altitudes. Operators who fly into these high-altitude airports should address the issues related to this environment because it carries the potential for insidious hypoxia and other conditions which can affect safety. It provides information to consider in developing operational procedures to address hypoxia concerns consistent with regulatory mandates.
Standard

Chemical Oxygen Supplies

2012-10-08
AIR1133A
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
Standard

Chemical Oxygen Supplies

2014-10-30
AIR1133B
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated

2004-06-23
AS1214A
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, LINE SHUT OFF, MANUALLY OPERATED

1971-07-01
AS1214
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2000-10-01
AIR1358A
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

AEROSPACE INFORMATION REPORT FOR CONTINUOUS FLOW OXYGEN HOSE DISCONNECT FITTINGS

1991-09-01
AIR1358
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

USEFUL LIFE DETERMINATION CHEMICAL OXYGEN GENERATORS

1987-02-01
ARP1894
This document provides recommended guidelines for a comprehensive program to determine the useful life of chemical oxygen generators where useful life is defined as the sum of shelf and service life. Further, this document provides for a test program to determine with a sufficient level of confidence if the generators are suitable for further use and/or if the life limit has been reached. This program should include testing of generators of a representative sampling of a given year's production, of a particular part number, to provide a level of confidence sufficient to permit the units to be used for an additional specified time period.
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2014-10-16
AS452B
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

OXYGEN MASKS FOR NON-MILITARY AIRPLANES

1956-12-01
AS452
This specification covers the types of oxygen masks considered satisfactory for use in commercial transport aircraft at altitudes up to 25,000 ft. The types of masks covered are:
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2003-10-15
AS452A
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand