Refine Your Search

Topic

Search Results

Standard

Digital Annex of Medium/Heavy-Duty E/E Systems Diagnosis Nomenclature

2014-02-07
HISTORICAL
J2403DA_201402
This document is intended to supplement SAE J2403 by providing the content of Table 1, Table 2, and Table 3 from SAE J2403 in a form that can be sorted and searched for easier use. It is NOT intended as a substitute for the actual document, and any discrepancies between this Digital Annex and the published SAE J2403 document must be resolved in favor of the published document. This document provides the content of Table 1 and Table 2 published in SAE J2403 into the single table in the 'Term' tab, while the 'Recommended Term Definitions' tab provides the content of Table 3 in SAE J2403 and the 'Glossary' tab provides the content of Table 4 in SAE J2403.
Standard

Digital Annex of Medium/Heavy-Duty E/E Systems Diagnosis Nomenclature

2012-06-07
HISTORICAL
J2403DA_062012
This document is intended to supplement SAE J2403 by providing the content of Table 1, Table 2, and Table 3 from SAE J2403 in a form that can be sorted and searched for easier use. It is NOT intended as a substitute for the actual document, and any discrepancies between this Digital Annex and the published SAE J2403 document must be resolved in favor of the published document. This document provides the content of Table 1 and Table 2 published in SAE J2403 into the single table in the 'Term' tab, while the 'Recommended Term Definitions' tab provides the content of Table 3 in SAE J2403 and the 'Glossary' tab provides the content of Table 4 in SAE J2403.
Standard

Digital Annex of Medium/Heavy-Duty E/E Systems Diagnosis Nomenclature

2022-04-17
HISTORICAL
J2403DA_202204
This document is intended to supplement SAE J2403 by providing the content of Table 1, Table 2, and Table 3 from SAE J2403 in a form that can be sorted and searched for easier use. It is NOT intended as a substitute for the actual document, and any discrepancies between this Digital Annex and the published SAE J2403 document must be resolved in favor of the published document. This document provides the content of Table 1 and Table 2 published in SAE J2403 into the single table in the 'Term' tab, while the 'Recommended Term Definitions' tab provides the content of Table 3 in SAE J2403 and the 'Glossary' tab provides the content of Table 4 in SAE J2403.
Standard

OBD Communications Compliance Test Cases for Heavy-Duty Components and Vehicles

2023-06-13
CURRENT
J1939/84_202306
The purpose of this SAE Recommended Practice is to verify that vehicles and/or components are capable of communicating a required set of information, which is described by the diagnostic messages specified in SAE J1939-73, that is in accordance with off-board diagnostic tool interface requirements contained in the government regulations cited below. This document describes the tests, methods, and results for verifying diagnostic communications from an off-board diagnostic tool (i.e., scan tool) to a vehicle and/or component. SAE members have generated this document to serve as a guide for testing vehicles for compliance with ARB and other requirements for emissions-related on-board diagnostic (OBD) functions for heavy-duty engines used in medium- and heavy-duty vehicles. The development of HD OBD regulations by U.S.
Standard

Off-Board Diagnostic Connector

2011-10-05
HISTORICAL
J1939/13_201110
SAE J1939-13 specifies the diagnostic connectors used for off-board connection to a vehicle’s SAE J1939 communication links. The defined diagnostic connectors support connection to the twisted shielded pair media (SAE J1939-11), the Reduced Physical Layer unshielded twisted pair (SAE J1939-15), the unshielded twisted pair of SAE J1939-14, as well as the twisted unshielded quad media (ISO 11783-2).
Standard

Physical Layer, 500 Kbps

2011-10-05
HISTORICAL
J1939/14_201110
This document defines a physical layer having a higher bandwidth capacity than other physical layers defined for SAE J1939. Newer transceiver technologies are utilized to minimize EMI. This SAE Recommended Practice is intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Off-Board Diagnostic Connector

2016-10-25
CURRENT
J1939/13_201610
SAE J1939-13 specifies the diagnostic connectors used for off-board connection to a vehicle’s SAE J1939 communication links. The defined diagnostic connectors support connection to the twisted shielded pair media (SAE J1939-11), the unshielded twisted pair (SAE J1939-15), the twisted pair of (SAE J1939-14), as well as the twisted unshielded quad media (ISO 11783-2).
Standard

Physical Layer, 500 kbit/s

2022-04-05
CURRENT
J1939/14_202204
This document defines a physical layer having a higher bandwidth capacity than other physical layers defined for SAE J1939. Newer transceiver technologies are utilized to minimize EMI. CAN controllers are now available which support the flexible data rate frame format. These controllers, when used on SAE J1939-14 networks, must be restricted to use only the classical frame format compliant to ISO 11898-1:2015. This SAE Recommended Practice is intended for light- and heavy-duty vehicles on- or off-road, as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include, but are not limited to, on- and off-highway trucks and their trailers, construction equipment, and agricultural equipment and implements.
Standard

Physical Layer, 500 Kbps

2016-12-01
HISTORICAL
J1939/14_201612
This document defines a physical layer having a higher bandwidth capacity than other physical layers defined for SAE J1939. Newer transceiver technologies are utilized to minimize EMI. CAN controllers are now available which support the Flexible Data Rate Frame Format. These controllers, when used on SAE J1939-14 networks, must be restricted to use only the Classical Frame Format compliant to ISO 11898-1:2015. This SAE Recommended Practice is intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Physical Layer, 250 Kbps, Twisted Shielded Pair

2021-02-12
WIP
J1939/11

This document defines a physical layer having a robust immunity to EMI and physical properties suitable for harsh environments.

CAN controllers are available which support the CAN Flexible Data Rate Frame Format. These controllers, when used on SAE J1939-11 networks, must be restricted to use only the Classical Frame Format compliant to ISO 11898-1:2015.

These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.

Standard

Physical Layer, 250 Kbps, Twisted Shielded Pair

2012-09-12
HISTORICAL
J1939/11_201209
This document defines a physical layer having a robust immunity to EMI and physical properties suitable for harsh environments. These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Physical Layer, 250 Kbps, Twisted Shielded Pair

2016-12-06
CURRENT
J1939/11_201612
This document defines a physical layer having a robust immunity to EMI and physical properties suitable for harsh environments. CAN controllers are available which support the CAN Flexible Data Rate Frame Format. These controllers, when used on SAE J1939-11 networks, must be restricted to use only the Classical Frame Format compliant to ISO 11898-1:2015. These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Off-Board Diagnostic Connector

2021-02-15
WIP
J1939/13
SAE J1939-13 specifies the diagnostic connectors used for off-board connection to a vehicle’s SAE J1939 communication links. The defined diagnostic connectors support connection to the twisted shielded pair media (SAE J1939-11), the unshielded twisted pair (SAE J1939-15), the twisted pair of (SAE J1939-14), as well as the twisted unshielded quad media (ISO 11783-2).
Standard

Compliance

2015-06-04
HISTORICAL
J1939/82_201506
SAE J1939-82 Compliance describes the compliance tests and procedures to verify an SAE J1939 ECU will operate correctly on a SAE J1939 network. The purpose of these compliance procedures is to generate one or more test documents that outline the tests needed to assure that an ECU that is designed to operate as a node on a SAE J1939 network would do so correctly. SAE does not certify devices and these tests and their results do not constitute endorsement by SAE of any particular device. These tests are presented to allow testing of a device to determine self-compliance by the manufacturer of a device. The manufacturer can use its record of what procedures were run successfully to show the level of compliance with SAE J1939.
Standard

Network Management

2017-03-09
CURRENT
J1939/81_201703
SAE J1939-81 Network Management defines the processes and messages associated with managing the source addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of source addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of source addresses, network management also specifies initialization processes, requirements for reaction to brief power outages and minimum requirements for ECUs on the network.
Standard

Network Management

2011-06-30
HISTORICAL
J1939/81_201106
SAE J1939-81 Network Management defines the processes and messages associated with managing the source addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of source addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of source addresses, network management also specifies initialization processes, requirements for reaction to brief power outages and minimum requirements for ECUs on the network.
Standard

Network Management

2016-02-18
HISTORICAL
J1939/81_201602
SAE J1939-81 Network Management defines the processes and messages associated with managing the source addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of source addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of source addresses, network management also specifies initialization processes, requirements for reaction to brief power outages and minimum requirements for ECUs on the network.
Standard

Network Management

2018-07-23
WIP
J1939/81
SAE J1939-81 Network Management defines the processes and messages associated with managing the source addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of source addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of source addresses, network management also specifies initialization processes, requirements for reaction to brief power outages and minimum requirements for ECUs on the network.
Standard

Application - Configurable Messaging

2021-08-26
CURRENT
J1939/74_202108
The SAE J1939 documents are intended for light, medium, and heavy-duty vehicles used on or off road as well as appropriate stationary applications which use vehicle derived components (e.g. generator sets). Vehicles of interest include, but are not limited to, on- and off-highway trucks and their trailers, construction equipment, and agricultural equipment and implements. The purpose of these documents is to provide an open interconnect system for electronic systems. It is the intention of these documents to allow Electronic Control Units to communicate with each other by providing a standard architecture. This particular document, SAE J1939-74, describes the message structure for a set of messages which enable the user to determine and announce to others on the network, the parameter placement within a particular message from the special set of messages defined within this document.
Standard

Network Layer

2014-04-16
HISTORICAL
J1939/31_201404
SAE J1939-31 Network Layer describes the requirements and services for Network Interconnection ECUs (NIECU) that enable electronic control units (ECUs) on a network segment to intercommunicate with other ECUs on different network segments of the vehicle network. This document defines various types of NIECUs. The information in this document applies only to ECUs that are intended to provide networking services. It is not necessary for an ECU to provide any of these services in order to be compliant with the SAE J1939 protocol.
X