Refine Your Search

Search Results

Viewing 1 to 8 of 8
Standard

TEST FOR EVALUATING THE TORQUE-TENSION RELATIONSHIP OF BOTH EXTERNAL AND INTERNAL METRIC THREADED FASTENERS

1998-12-30
HISTORICAL
USCAR10
This standard provides a test method for determining the torque-tension relationship of both external and internal metric threaded fasteners for the purpose of measuring the frictional characteristics of the threaded fasteners. The results obtained by this test are relevant to the test conditions only and should not be utilized for specific applications.
Standard

DIMENSIONAL AND PERFORMANCE SPECIFICATION FOR AFTER-MARKET GASOLINE ENGINE OIL FILTERS

2021-05-13
CURRENT
USCAR36-1
This specification defines the dimensional and performance requirements for aftermarket spin-on oil filters intended for use on gasoline engines. Filters meeting this specification may also be suitable for use on some diesel applications. Filters meeting these dimensional limits are intended to meet the oil filter fit and package requirements for engine and vehicle designs. Filters meeting the performance requirements are intended to maintain sufficient durability to support typical 10000 mile oil change intervals. Some OEM engines may require special filters for which this specification would not support. Filters that meet or exceed this specification requirements for both dimensional and performance can claim “Conformance to SAE/USCAR - 36 Specifications.” Filters that meet just the performance specifications (ie. may have different thread) can claim “Aligns to SAE/USCAR - 36 Performance Specifications.”
Standard

Automotive Grade Coaxial Cable Performance Specification

2006-01-02
HISTORICAL
USCAR29
This document specifies dimensional, functional and visual requirements for Automotive grade coaxial cable. This material will be designated AG for general-purpose automotive applications or AG LL for low loss applications. It is the responsibility of the user of this cable to verify the suitability of the selected product (based on dimensional, mechanical, electrical and environmental requirements) for its intended application. It is the responsibility of the supplier to retain and maintain records as evidence of compliance to the requirements detailed in this standard.
Standard

AUTOMOTIVE GRADE COAXIAL CABLE PERFORMANCE SPECIFICATION

2022-03-15
CURRENT
USCAR29-1
This document specifies dimensional, functional and visual requirements for Automotive grade coaxial cable. This material will be designated AG for general-purpose automotive applications or AG LL for low loss applications. It is the responsibility of the user of this cable to verify the suitability of the selected product (based on dimensional, mechanical, electrical and environmental requirements) for its intended application. It is the responsibility of the supplier to retain and maintain records as evidence of compliance to the requirements detailed in this standard.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE RF CONNECTOR SYTEMS

2002-02-22
HISTORICAL
USCAR17
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors and components for coaxial cable connection systems (hereafter referred to as RF connectors) in road vehicle applications. The intent of this specification is to qualify RF connectors that operate at frequencies greater than 200 MHz. This specification does not apply to single conductor wire or twisted pair connection systems. The RF connection system will be qualified for specific coaxial cable; the qualified coaxial cable and frequency range of interest must be listed on the connector drawing. Changing coaxial cable necessitates re-qualification. This specification is a supplement to the SAE/USCAR-2 Performance Standard for Automotive Electrical Connector Systems and all requirements herein must be met in addition to all requirements of SAE/USCAR-2, unless otherwise specified.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE RF CONNECTOR SYSTEMS

2002-11-18
HISTORICAL
USCAR17-1
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors and components for coaxial cable connection systems (hereafter referred to as RF connectors) in road vehicle applications. The intent of this specification is to qualify RF connectors that operate at frequencies greater than 200 MHz. This specification does not apply to single conductor wire or twisted pair connection systems. The RF connection system will be qualified for a specific coaxial cable; the qualified coaxial cable and frequency range of interest must be listed on the connector drawing. Changing coaxial cable necessitates re-qualification.
Standard

ENGINE OIL PUMP PERFORMANCE AND DURABILITY TEST PROCEDURES

2023-03-23
CURRENT
USCAR46
SAE/USCAR-46 defines test methods and outputs for engine oil pump bench testing. Performance and durability testing are the primary focus of this standard. This is written to specifically address testing of electronically controlled variable displacement pumps but can be adapted to mechanically controlled pumps and other pump technologies as needed. This standard outlines critical inputs and outputs in order to perform the testing and report results, but does not specifically set the acceptance standards or pass/fail criteria. Acceptance criteria must be set by the customer.
Standard

HIGH VOLTAGE CONNECTOR PERFORMANCE SUPPLEMENT TO SAE/USCAR-2

2008-08-27
CURRENT
USCAR37
Procedures included within this specification supplement are, when used in conjunction with SAE/USCAR 2, intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in high voltage (60~600V) road vehicle applications. These procedures are applicable to terminals used for In-Line, Header, and Device Connector systems with and without Shorting Bars. This supplement applies to both sealed and unsealed connection systems.
X