Refine Your Search

Topic

Search Results

Viewing 1 to 16 of 16
Technical Paper

Integrated CO2 and Humidity Control by Membrane Gas Absorption

1997-07-14
972560
In a harmonized ESA/NIVR project the performance of membrane gas absorption for the simultaneous removal of carbon dioxide and moisture has been determined experimentally at carbon dioxide and humidity concentration levels representative for spacecraft conditions. Performance data at several experimental conditions have been collected. Removal of moisture can be controlled by the temperature of the absorption liquid. Removal of carbon dioxide is slightly affected by the temperature of the absorption liquid. Based on these measurements a conceptual design for a carbon dioxide and humidity control system for the Crew Transport Vehicle (CTV) is made. For the regeneration step in this design a number of assumptions have been made. The multifunctionality of membrane gas absorption makes it possible to combine a number of functions in one compact system.
Technical Paper

Columbus Launch Preparation - Final System ATCS Tests Summary and Lessons Learned

2008-06-29
2008-01-2033
Final preparation and configuration of the Columbus module at the Kennedy Space Center (KSC) required the performance of system level tests with the Active Thermal Control System (ATCS). These tests represented the very last system level activities having been concluded on the Columbus module before handover to NASA for space shuttle integration. Those very last tests, performed with the ATCS comprised the final ATCS Leakage Test, the final calibration and adjustment of the Water Flow Selection Valves (WFSV) and Water On/Off Valves (WOOV) as well as a sophisticated ATCS Residual Air Removal test. The above listed tests have been successfully performed and test data evaluated for verification closeout as well as input delivery for operational Flight Rules and Procedures. Some of the above mentioned tests have been performed the first time hence, a succeeding lessons learned collection followed in order to improve the perspectives of future tests.
Technical Paper

DOMEX-2 Thermal Design, Testing and Commissioning in Support to the SMOS Mission

2009-07-12
2009-01-2375
In recent years there is growing interest, on the part of the remote sensing community, in using the Antarctic area, for calibrating and validating data of satellite-borne microwave radiometers. With a view to the launching of the ESA's SMOS satellite, which is a satellite designed to observe soil moisture over the Earth landmasses, salinity over the oceans and to provide observations over regions of ice and snow, an experimental activity called DOMEX was started at Dome-C Antarctica. The main scientific objectives of this activity are to provide microwave data for SMOS satellite calibration and in particular: the continuous acquisition of a calibrated time-series of microwave and thermal Infrared (8-14micron) emission over an entire Austral annual cycle, the acquisition of a long time-series of snow measurements and the acquisition of relevant local atmospheric measurements from the local weather station. This paper is focusing on the thermal design, analysis and testing of Domex-2.
Technical Paper

Results of Breadboard Tests Withan Integrated CO2, Humidity and Thermal Control System

2003-07-07
2003-01-2348
Membrane gas absorption and desorption (MGA/MGD) for the removal of CO2 in manned spacecraft or other enclosed environment is subject of study by Stork and TNO for many years. The system is based on the combination of membrane separation and gas absorption. Advantage of this technology is that the system not only can be used to remove the carbon dioxide but also to control the relative humidity and temperature. Absorption of moisture and heat is achieved by cooling the absorption liquid below the dewpoint temperature of the gas stream. From the start in 1995, the Crew Transfer Vehicle is used as a basis for the design (1,2). Compared to the planned air conditioning system, consisting of a condensing heat exchanger, LiOH cartridges and a water evaporator assembly, MGA/MGD shows advantage in volume, mass and power consumption. The absorption liquid circulates through the spacecraft thermal control loop, replacing the coolant water.
Technical Paper

An Experimental Model of a Biological Life Support System with the Intra-system Mass Exchange Closed to a High Degree, Based on “Biological Combustion” of Dead-end Plant Residues

2003-07-07
2003-01-2417
This work concerns the model of a biological life support system consisting of higher plants, a unit of “biological combustion”, a physicochemical reactor, and 1/30 of a human. The cycling of the main biogenic elements of the system, water, and carbon dioxide was closed to a high degree (more than 95%). Experimental-theoretical analysis of the cycling processes in the system was based on the calculations of mass exchange rates dynamics and some stoichiometric equations. The model was designed for the study of mechanisms of material transformation and the directions of mass exchange processes in the artificial ecosystems.
Technical Paper

Application of EcosimPro to Bio-regenerative Life Support Components

2003-07-07
2003-01-2410
EcosimPro‘s capability to solve a problem domain that can be represented by Differential-Algebraic Equations (DAE) and discrete events, make it particularly attractive to model bio-regenerative life support systems. Components of the envisaged MELiSSA bio-regenerative life support system are driven by the adaptation of the biomass to changing environmental conditions, which could be of continuous nature, such as depletion or replenishment of nutrition, and discrete events, such as step changes in light fluxes and control interactions. The authors first present simulation results for a closed and an open loop bio-regenerative system. The simulations include the establishment of a quasi-steady state, reaction to step changes including a mass balance check, and the simulation of a controlled bioreactor. The results demonstrate the capability of this tool to model components of a bio-regenerative life support system, as well as an entire bio-regenerative life support system in the future.
Technical Paper

First Use of ECOSIM in Air Management Systems

1992-07-01
921292
ECOSIM is a software tool for the simulation of Environmental Control and Life Support (ECLS) systems which has been developed for the European Space Agency. A preliminary model of the Hermes Air Management System has been developed during the ECOSIM testing in order to assess the functionality of the software and to verify its results with those obtained from previous simulation tools. The model represents the Hermes cabin with its crew and it includes submodels for the sub-systems performing the following functions: Temperature and Humidity Control. Total Pressure and Composition Control. Air revitalisation. The interactions between these different subsystem are taken into account by the model, while many of the previous simulations made assumptions to decouple the different subsystems (e.g: a constant cabin temperature has been assumed during cabin depressurization transients, to decouple the pressure control section from the air conditioning section).
Technical Paper

Thermal Control Design of the European Polar Platform

1992-07-01
921326
The ESA Polar Platform, as part of the ESA Columbus Development Programme, is scheduled to be launched as single passenger by an Ariane 5 vehicle in mid 1998. The multimission platform is designed to accommodate a wide range of payload complements to be flown on a series of missions in order to satisfy the growing future earth observation needs in continuation of the current ERS programme. Multi-mission capability is achieved by design modularity wherever feasible and cost-effective. This paper describes the thermal control design of the Polar Platform which follows its modular configuration and which has to cope with a wide range of generic performance parameters, whilst being adaptable to provide optimised performance for specific missions. Special thermal control features are highlighted as the software and hardware controlled heater systems, thermal doublers using carbon / carbon material and the battery compartment heat pipe radiator.
Technical Paper

Improving the Columbus Integrated Overall Thermal Mathematical Model (IOTMM) Using Computational Fluid Dynamics (CFD)

2005-07-11
2005-01-2796
The cabin space of the Columbus APM is well ventilated by air entering through multiple air diffusers and exiting via the return grid and hatch. Therefore, the heat transfers by bulk fluid motion and by convection to the walls need to be experimentally and/or numerically investigated and implemented in the thermal mathematical models (TMM) describing the cabin. CFD analysis provided key data on the thermal couplings due to convective heat transfer and bulk fluid motion for the thermal mathematical model, which in turn was used to correlate test data from an environmental control system test and to provide supplemental information on assumptions used in the lumped capacitance model. This paper presents the logic and results of the steady-state CFD analysis, the potential implementation of the results in a thermal mathematical model, and compares these results with test data obtained during a separate Columbus cabin ventilation qualification test.
Technical Paper

Phases Management for Advanced Life Support Processes

2005-07-11
2005-01-2767
For a planetary base, a reliable life support system including food and water supply, gas generation and waste management is a condition sine qua non. While for a short-term period the life support system may be an open loop, i.e. water, gases and food provided from the Earth, for long-term missions the system has to become more and more regenerative. Advanced life support systems with biological regenerative processes have been studied for many years and the processes within the different compartments are rather complete and known to a certain extent. The knowledge of the associated interfaces, the management of the input and output phases: liquid, solid, gas, between compartments, has been limited. Nowadays, it is well accepted that the management of these phases induces generic problems like capture, separation, transfer, mixing, and buffering. A first ESA study on these subjects started mid 2003.
Technical Paper

Columbus Environmental Control System Tests - Verification of ATCS and ECLSS Performance

2005-07-11
2005-01-3117
Verification of the Integrated Overall Thermal Mathematical Model (IOTMM) is one of the last tasks in the thermal and environmental control area of the Columbus module. For this purpose a specific test covering as well thermal-hydraulic performance tests as Environmental Control and Life Support (ECLS) cabin temperature control functions has been defined and performed on the european Columbus Protoflight Model (PFM) in Bremen in 2003. This Environmental Control System test was successful for all Active Thermal Control System (ATCS) related thermal-hydraulic functions and could provide sufficient data for a proper IOTMM correlation. However, it failed to verify the ECLS related functions as cabin temperature control and ventilation. Data, which have been generated during this first test, could not be used for a successful IOTMM correlation related to ECLS subsystem performance and modelling.
Technical Paper

Enhancing Lumped Parameter TMM Using Computational Fluid Dynamics and Scripting

2004-07-19
2004-01-2398
Lumped parameter models are extensively used to calculate the thermal state of structures in a defined environment. Such models rely on the correct estimation of thermal couplings between the thermal nodes. Frequently, such conductances are difficult to establish using standard methods or given correlations. This paper presents methods to determine linear bulk flow conductances and linear conductances due to conduction and convection using computational fluid dynamics (CFD). The methods take advantage of grids of finite elements or finite volumes to model the structure, and the solution of the Navier-Stokes equations using CFD. Conductances due to conduction are determined in two ways. First, the conductance is calculated by means of geometric and material property analysis. Second, a thermal case was applied to compute the conductance. The results were compared subsequently. Fluid and convective conductances were calculated applying thermal and fluid dynamics cases.
Technical Paper

Integrated CO2, Humidity and Thermal Control by Membrane Gas Absorption

2000-07-10
2000-01-2353
Membrane gas absorption for the control of CO2 in manned spacecrafts is studied by Stork and TNO. Membrane Gas Absorption (MGA) is based on the combination of membrane separation and gas absorption. The cabin air of a spacecraft is fed along one side of a hydrophobic membrane. The air diffuses through the membrane and the CO2 is selectively absorbed by an absorption liquid. Experiments showed that the MGA system can not only be used for the removal of the carbon dioxide but also can be applied to control the relative humidity and temperature of the cabin atmosphere. Absorption of moisture and heat is achieved by cooling the absorption liquid below the dewpoint temperature of the gas stream. This paper deals with the design aspects of a MGA system for combined CO2, humidity and thermal control aboard the Crew Transfer Vehicle. Furthermore, design data are presented for a similar system aboard the International Space Station.
Technical Paper

Thermal Control System of the Automated Transfer Vehicle

2000-07-10
2000-01-2307
The Automated Transfer Vehicle (ATV) is a European Space Agency (ESA) servicing and logistics transportation system for the periodic re-supply of the International Space Station (ISS). The ATV will be launched by Ariane 5 and will provide the following services to the ISS: refuelling of the ISS (transfer of fuel from ATV to the station), reboost of the ISS (increasing the station’s orbit altitude, using the ATV’s propulsion system), delivery of cargo such as compressed air, water and pressurised payloads to the station, destruction of waste from the station. The ATV is composed of the so-called Spacecraft (SC) and an Integrated Cargo Carrier (ICC). The Spacecraft includes the propulsion, reboost and attitude control systems, the avionics and the solar generator system.
Technical Paper

Current Status of the ESA FTIR-Based Multi-Component Monitoring System for Spacecraft Air Analysis

2000-07-10
2000-01-2302
This paper presents the status of ongoing BB studies for an optimized trace gas monitoring (TGM) system configured to simultaneously and quasi-online detect (quantitatively and qualitatively) 30 different trace gases in manned spacecraft. The system principle relies on the detection of molecule absorption lines in the infrared being converted into a measured spectrum by a Fourier Transform Infrared (FTIR) Spectrometer. The work is based on 10 years study phases aiming now towards performance demonstration on unknown gas mixtures and an in-flight demonstration on Space Shuttle or ISS. The theoretical background, sensor combinations, SW principle descriptions and multi-module monitoring strategies have been reported earlier (please refer to reference [1] - [4], [6]).
Technical Paper

Thermal Balance Testing of the European Robotic Arm

2000-07-10
2000-01-2496
As part of the European contribution to the Russian segment of the International Space Station (ISS), the European Robotic Arm (ERA) is designed under contract of the European Space Agency by Fokker Space as the Prime contractor. The particularly challenging aspect of the ERA thermal design is to enable ERA operation under all possible in-orbit thermal environmental conditions which are to be experienced throughout its 10 year life. These conditions can be between extreme cold without sunlight for hibernation to extreme hot with ERA operating in full sunlight in close vicinity to a large station item, for instance, the solar arrays. First a short description of the ERA system is given with a summary of the main thermal design features. The system level thermal balance test on the ERA Engineering Qualification Model (EQM) is intended to validate the system level thermal model, which consists of the subsystem thermal models as supplied by the respective subcontractors.
X