Refine Your Search

Search Results

Viewing 1 to 14 of 14
Journal Article

Off-Gassing and Particle Release by Heated Polymeric Materials

2008-06-29
2008-01-2090
Polymers are one of the major constituents in electrical components. A study investigating pre-combustion off-gassing and particle release by polymeric materials over a range of temperatures can provide an understanding of thermal degradation prior to failure which may result in a fire hazard. In this work, we report simultaneous measurements of pre-combustion vapor and particle release by heated polymeric materials. The polymer materials considered for the current study are silicone and Kapton. The polymer samples were heated over the range 20 to 400°C. Response to vapor releases were recorded using the JPL Electronic Nose (ENose) and Industrial Scientific's ITX gas monitor configured to detect hydrogen chloride (HCl), carbon monoxide (CO) and hydrogen cyanide (HCN). Particle release was monitored using a TSI P-TRAK particle counter.
Technical Paper

Viral Populations within the International Space Station's Internal Active Thermal Control System Ground Support and Potential Flight Hardware

2007-07-09
2007-01-3108
The Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) contains an aqueous, alkaline fluid (pH 9.5±0.5) that aids in maintaining a habitable environment for the crew. Because microbes have significant potential to cause disease, adverse effects on astronaut health, and microbe-induced corrosion, the presence of both bacteria and viruses within IATCS fluids is of concern. This study sought to detect and identify viral populations in IATCS samples obtained from the Kennedy Space Center as a first step towards characterizing and understanding potential risks associated with them. Samples were concentrated and viral nucleic acids (NA) extracted providing solutions containing 8.87-22.67 μg NA per mL of heat transfer fluid. After further amplification viral DNA and cDNA were then pooled, fluorescently labeled, and hybridized onto a Combimatrix panvira 12K microarray containing probes for ∼1,000 known human viruses.
Technical Paper

Monitoring Pre-Combustion Event Markers by Heating Electrical Wires

2009-07-12
2009-01-2543
Simultaneous measurements were made for particle releases and off-gassing products produced by heating electrical wires. The wire samples in these experiments were heated to selected temperatures in a heating chamber and responses to vapor releases were recorded by the JPL Electronic Nose (ENose) and an Industrial Scientific ITX gas-monitor; particles released were detected by a TSI P-Trak particle counter. The temperature range considered for the experiment is room temperature (24−26°C) to 500 °C. The results were analyzed by overlapping responses from the ENose, ITX gas sensors and P-Trak, to understand the events (particle release/off-gassing) and sequence of events as a function of temperature and to determine qualitatively whether ENose may be used to detect pre-combustion event markers.
Technical Paper

Mid-IR Semiconductor Lasers for Chemical Sensing

2003-07-07
2003-01-2551
The development of mid-IR semiconductor diode lasers based on type-II interband cascade structures is presented. How these diode lasers can be developed to meet the requirements in chemical sensing applications is discussed.
Technical Paper

Mechanically Pumped Fluid Loop Technologies for Thermal Control of Future Mars Rovers

2006-07-17
2006-01-2035
Future planetary science missions planned for Mars are expected to be more complex and thermally challenging than any of the previous missions. For future rovers, the operational parameters such as landing site latitudes, mission life, distance traversed, and rover thermal energy to be managed will be significantly higher (two to five times) than the previous missions. It is a very challenging problem to provide an effective thermal control for the future rovers using traditional passive thermal control technologies. Recent investigations at the Jet Propulsion Laboratory (JPL) have shown that mechanical pump based fluid loops provide a robust and effective thermal control system needed for these future rovers. Mechanical pump based fluid loop (MPFL) technologies are currently being developed at JPL for use on such rovers. These fluid loops are planned for use during spacecraft cruise from earth to Mars and also on the Martian surface operations.
Technical Paper

The Applicability of Past Innovative Concepts to the Technology for New Extremely Large Space Antenna/Telescope Structures

2006-07-17
2006-01-2063
Early development of concepts for space structures up to 1000 meters in size was initiated in the early 1960's and carried through the 1970's. The enabling technologies were self-deployables, on-orbit assembly, and on-orbit manufacturing. Because of the lack of interest due to the astronomical cost associated with advancing the on-orbit assembly and manufacturing technologies, only self-deployable concepts were subsequently pursued. However, for over 50 years, potential users of deployable antennas for radar, radiometers, planar arrays, VLBF and others, are still interested and constantly revising the requirements for larger and higher precision structures. This trend persists today. An excellent example of this trend is the current DARPA/SPO ISAT Program that applies self-deployable structures technology to a 300 meter long active planar array radar antenna. This ongoing program has created a rare opportunity for innovative advancement of state-of-the-art concepts.
Technical Paper

Chemical Sensor Testing for Space Life Support Chemical Processing: Part I. Moisture Sensors

1994-06-01
941263
In support of the National Aeronautics and Space Administration(NASA), a laboratory has been established at the Jet Propulsion Laboratory (JPL) to evaluate the characteristics of chemical sensors which are candidates for use in a controlled chemical processing life support system. Such a facility is required for characterizing those sensors under development as well as those commercially available but whose functional properties are typically based upon operating in industrial environments that will not be completely synonomous with space operations. Space environments, such as an orbiting station or lunar base, will generally have different sensor requirements than terrestrial applications with respect to size, multifunctionality, sensitivity, reliability, temperature, ruggedness, mass, consumables, life, and power requirements. Both commercially available and developmental moisture sensors have been evaluated.
Technical Paper

Expanding the Analyte Set of the JPL Electronic Nose to Include Inorganic Species

2005-07-11
2005-01-2880
An array-based sensing system based on 32 polymer/carbon composite conductometric sensors is under development at JPL. Until the present phase of development, the analyte set has focused on organic compounds (common solvents) and a few selected inorganic compounds, notably ammonia and hydrazine. The present phase of JPL ENose development has added two inorganics to the analyte set: mercury and sulfur dioxide. Through models of sensor-analyte response developed under this program coupled with a literature survey, approaches to including these analytes in the ENose target set have been determined.
Technical Paper

Thermal Engineering of Mars Entry Non-Ablative Aeroshell Part 1

1999-07-12
1999-01-2198
A transient thermal analysis of a Carbon/Carbon (C/C) Mars Entry Non-Ablative Aeroshell Assembly was performed to determine the maximum temperatures it would reach during a Mars entry. The purpose of this thermal analyses was to (1) determine the maximum temperatures of the 5 layers and the close-out which make up the aerothermal shield and (2) to transmit these temperatures from SINDA/G finite difference format to finite element format in COSMOS/M structures/dynamic models using Technical Alliance Group (TAG) developed SINDA/ G temperature translator software (STT).
Technical Paper

Model for Grain Growth in AMTEC Electrodes

1999-08-02
1999-01-2703
The power produced by an AMTEC is dependent on the porosity of the electrode layers deposited on the surface of the BASE tubes. The elevated temperatures at which these power generators operate result in a slow growth or coalescence of the grains that comprise the electrode layers thereby reducing porosity and effective surface area. The lifetime of AMTEC electrodes is therefore related to the rate of grain growth of the electrode material. A preliminary model has been developed to determine the rate of grain growth over the operational lifetime of an AMTEC. This model examines the conditions for continuous growth as a function of the relative sizes, boundary and activation energies and mobilities of the grains. An assumption of strain-free growth has been made in determining the factors for normal growth. Experimental measurements for titanium nitride alloy electrodes are compared with this model. Predictions are made for performance lifetimes out to 10 years.
Technical Paper

Sorbent Bed Acquisition and Compression of Carbon Dioxide from the Mars Atmosphere

2000-07-10
2000-01-2237
Human exploration of Mars as well as unmanned sample return missions from Mars can benefit greatly from the use of propellants produced from the resources available from the atmosphere of Mars. The first major step of any in-situ propellant production (ISPP) system is to acquire carbon dioxide (CO2) from the Mars atmosphere and compress it for further chemical processing. One system that performs this step is called a Mars Atmosphere Acquisition and Compression (MAAC) unit. A simple prototype MAAC was developed by JPL as part of the Mars ISPP Precursor (MIP) experiment package for inclusion on the Mars 2001 Surveyor Lander. The MAAC consists of a valved enclosure packed with a sorbent material which selectively adsorbs CO2 from the Mars atmosphere (valves open), desorbs and compresses the acquired CO2 by heating (valves closed) and then delivers the pressurized CO2 to an oxygen generating system where the CO2 is electrolyzed to produce oxygen.
Journal Article

Development of the Orbiting Carbon Observatory Instrument Thermal Control System

2008-06-29
2008-01-2065
The Orbiting Carbon Observatory (OCO) will carry a single science instrument scheduled for launch on an Orbital Sciences Corporation LeoStar-2 architecture spacecraft bus in December 2008. The science objective of the OCO instrument is to collect spaced-based measurements of atmospheric CO2 with the precision, resolution, and coverage needed to identify CO2 sources and sinks and quantify their seasonal variability. The instrument will permit the collection of spatially resolved, high resolution spectroscopic observations of CO2 and O2 absorption in reflected sunlight over both continents and oceans. These measurements will improve our ability to forecast CO2 induced climate change. The instrument consists of three bore-sighted, high resolution grating spectrometers sharing a common telescope with similar optics and electronics.
Journal Article

ATCC 29669 Spores Show Substantial Dry Heat Survivability

2008-06-29
2008-01-1982
Bacillus sp. ATCC 29669 was isolated from microbial fallout in clean rooms during the assembly of the Viking Spacecraft missions to Mars, making it a potential contamination concern for outbound space missions. Spores from this bacterial strain were found to be thirty times more resistant to dry heat than B. atrophaeus. Spore inactivation rates under vacuum controlled humidity were faster than rates obtained under ambient humidity. Inactivation rates for these heat resistant spores are important considerations for planetary protection implementation where temperature, time and humidity conditions are used to estimate the effectiveness of dry heat microbial reduction (DHMR) procedures.
X