Refine Your Search

Search Results

Viewing 1 to 7 of 7
Technical Paper

Advanced Technology Spacesuit Ejector Testing and Analysis

1998-07-13
981670
An experimental study has been made of compressible jet mixing in an axisymmetric ejector of converging-diverging geometry. Three different jet sizes, 0.01, 0.0235, and 0.045 in. diameter were tested with three different mixer sizes, 0.25, 0.286, and 0.36 in. diameter. Jet and mixer combination were tested along with varying jet to mixer distances. The jet pressure varied from 20 to 200 psig, jet mass varied from 0.3 lbm/hr to 10 lbm/hr., and jet temperature varied from 21 to 24 deg. F. The secondary loop pressure varied from 3.7 to 25 psia, secondary mass flow varied from 1 to 70 lbm/hr, secondary loop pressure drop varied from 4 inH20 to 10 inH20, and secondary loop temperature varied same as jet temperature. The mass flow ratio was in the range of 2 to 14. The results were analyzed and compared with the Hickman and Nuckols and Sexton prediction models. The loss factor in Nuckols and Sexton model was adjusted to match the test results.
Technical Paper

Dynamic Thermal Management System Modeling of a More Electric Aircraft

2008-11-11
2008-01-2886
Advancements in electrical, mechanical, and structural design onboard modern more electric aircraft have added significant stress to the thermal management systems (TMS). A thermal management system level analysis tool has been created in MATLAB/Simulink to facilitate rapid system analysis and optimization to meet the growing demands of modern aircraft. It is anticipated that the tracking of thermal energy through numerical integration will lead to more accurate predictions of worst case TMS sizing conditions. In addition, the non-proprietary nature of the tool affords users the ability to modify component models and integrate advanced conceptual designs that can be evaluated over multiple missions to determine the impact at a system level.
Technical Paper

Dynamic Model of the BIO-Plex Air Revitalization System

2001-07-09
2001-01-2318
The BIO-Plex facility will need to support a variety of life support system designs and operational strategies. These systems will be tested and evaluated in the BIO-Plex facility. An important goal of the life support program is to identify designs that best meet all size and performance constraints for a variety of possible future missions. Integrated human testing is a necessary step in reaching this goal. System modeling and analysis will also play an important role in this endeavor. Currently, simulation studies are being used to estimate air revitalization buffer and storage requirements in order to develop infrastructure requirements of the BIO-Plex facility. Simulation studies are also being used to verify that the envisioned operation strategy will be able to meet all performance criteria. In this paper, a simulation study is presented for a nominal BIO-Plex scenario with a high-level of crop growth.
Technical Paper

Adsorption Modeling with ACM: ISS CDRA Simulation

2002-07-15
2002-01-2345
A dynamic simulation of the ISS CDRA hardware was created using the Aspen Custom Modeler software platform. The dynamic model calculates the material and energy balances that describe the system properties. The model was calibrated by comparison to test data results from a flight-like CDRA at NASA Marshall Space Flight Center. While other FORTRAN models of the CDRA already exist, developing an ACM simulation is the first step towards creating a generic tool to simulate larger collections of life support hardware. The ACM tool should make it possible to be very flexible when rearranging these models to simulate possible configurations of the life support subsystems that could be used in the future, especially for advanced life support applications.
Technical Paper

Advances in Testing and Analytical Simulation Methodologies to Support Design and Structural Integrity Assessment of Large Monolithic Parts

2006-09-12
2006-01-3179
Significant system efficiency gains can be achieved in high-performance aircraft via a unitized structure that reduces parts count. For instance, reduced parts count leads to substantial engineering logistic cost savings through higher levels of subsystem and mounting hardware integration. It also creates performance benefits by eliminating structural connections. Residual stress management, however, remains a major obstacle to capturing full benefits and broadening the application of unitized structure solutions. This paper describes how Alcoa and others are developing tools to overcome limitations in current testing, evaluation, and design practices attributed to residual stress effects. The authors present recent advancements in fracture toughness and fatigue crack growth characterization, along with a new, integrated approach for improved accounting of residual stress effects during fracture critical component design, manufacturing planning, and life management.
Technical Paper

Noncondensible Gas, Mass, and Adverse Tilt Effects on the Start-up of Loop Heat Pipes

1999-07-12
1999-01-2048
In recent years, loop heat pipe (LHP) technology has transitioned from a developmental technology to one that is flight ready. The LHP is considered to be more robust than capillary pumped loops (CPL) because the LHP does not require any preconditioning of the system prior to application of the heat load, nor does its performance become unstable in the presence of two-phase fluid in the core of the evaporator. However, both devices have a lower limit on input power: below a certain power, the system may not start properly. The LHP becomes especially susceptible to these low power start-ups following diode operation, intentional shut-down, or very cold conditions. These limits are affected by the presence of adverse tilt, mass on the evaporator, and noncondensible gas in the working fluid.
Journal Article

Electrical Energy Storage to Meet Evolving Aircraft Needs

2012-10-22
2012-01-2199
The value of “ultracapacitors” (also referred to as “supercapacitors” or “electric double layer capacitors” in some literature) as an augmentation device when placed in parallel with “electrochemical” energy storage (i.e. battery) is presented in this paper. Since ultracapacitors possess unique attributes due to their higher value of energy storage density (or Joules/WattHrs per mass) compared to conventional capacitors while maintaining the peak power providing capability (to some degree) typical of conventional capacitors they may provide a near term solution in applications demanding longer battery operating life when placed in parallel. Such demands may be pronounced by the onset of More-Electric-Aircraft peak loads and “cold-crank” Auxiliary Power Unit (APU) electric-starting in demanding cold temperature environments.