Refine Your Search

Topic

Search Results

Viewing 1 to 16 of 16
Standard

Aircraft Flexible Tanks General Design and Installation Recommendations

2019-05-07
CURRENT
AIR1664A
This SAE Aerospace Information Report (AIR) includes general information about the various types and styles of flexible tanks and the tank-mounted fittings that adapt the tank to the surrounding structure and fluid-system plumbing. Recommendations are given relative to the dimensional layout of the tank when these recommendations serve to avoid tank fabrication problems and tank/structure interface problems. As a part of these recommendations, critical dimensions of plumbing adapter fittings are discussed and recommendations made. Tank manufacturing tolerances are given. Recommendations are made relative to cavity design and preparation to facilitate a reliable installation. The special installation requirements of nonself-sealing, self-sealing, and crash-resistant tanks are discussed. This document is not intended to replace the information or requirements of the military and commercial procurement specifications listed in Section 2.
Standard

AIRCRAFT FLEXIBLE TANKS GENERAL DESIGN AND INSTALLATION RECOMMENDATIONS

1994-09-01
HISTORICAL
AIR1664
This Aerospace Information Report (AIR) includes general information about the various types and styles of flexible tanks and the tank-mounted fittings that adapt the tank to the surrounding structure and fluid-system plumbing. Recommendations are given relative to the dimensional layout of the tank when these recommendations serve to avoid tank fabrication problems and tank/structure interface problems. As a part of these recommendations, critical dimensions of plumbing adapter fittings are discussed and recommendations made. Tank manufacturing tolerances are given. Recommendations are made relative to cavity design and preparation to facilitate a reliable installation. The special installation requirements of non-self-sealing, self-sealing, and crash-resistant tanks are discussed. This document is not intended to replace the information or requirements of the military and commercial procurement specifications listed in section 3.
Standard

Minimization of Electrostatic Hazards in Aircraft Fuel Systems

2013-08-09
HISTORICAL
AIR1662A
This SAE Aerospace Information Report (AIR) provides background information, technical data and related technical references for minimization of electrostatic hazards in aircraft fuel systems. Techniques used to minimize the electrostatic hazard include: a Reducing fueling rate into tank bays including use of multiple refueling inlet nozzles. b Reducing refuel plumbing flow velocities. c Introducing fuel into the tank at a low velocity near the bottom and directing it to impinge upon a grounded conducting surface. d Avoiding electrically isolated conductors in the fuel tank. e Using conductivity additives in the fuel.
Standard

FIRE TESTING OF FLUID HANDLING COMPONENTS FOR AIRCRAFT ENGINES AND AIRCRAFT ENGINE INSTALLATIONS

1996-08-01
HISTORICAL
AS4273
This document establishes requirements, test procedures, and acceptance criteria for the fire testing of fluid handling components and materials used in aircraft fluid systems. It is applicable to fluid handling components other than those prescribed by AS1055 (e.g., hoses, tube assemblies, coils, fittings). It also is applicable to materials, wiring, and components such as reservoirs, valves, gearboxes, pumps, filter assemblies, accumulators, fluid-cooled electrical/electronic components, in-flight fluid system instrumentation, hydromechanical controls, actuators, heat exchangers, and manifolds. These components may be used in fuel, lubrication, hydraulic, or pneumatic systems.
Standard

Considerations on Ice Formation in Aircraft Fuel Systems

2006-08-24
HISTORICAL
AIR790C
Ice formation in aircraft fuel systems results from the presence of dissolved and undissolved water in the fuel. Dissolved water or water in solution with hydrocarbon fuels constitutes a relatively small part of the total water potential in a particular system with the quantity dissolved being primarily dependent on the fuel temperature and the water solubility characteristics of the fuel. One condition of undissolved water is entrained water such as water particles suspended in the fuel as a result of mechanical agitation of free water or conversion of dissolved water through temperature reduction. Another condition of undissolved water is free water which may be introduced as a result of refueling or the settling of entrained water which collects at the bottom of a fuel tank in easily detectable quantities separated by a continuous interface from the fuel above. Water may also be introduced as a result of condensation from air entering a fuel tank through the vent system.
Standard

FLUID SYSTEM COMPONENT SPECIFICATION PREPARATION CRITERIA

1983-06-01
HISTORICAL
AIR1082A
The "Scope" section may be a very brief statement describing the coverage of the specification for a simple device, or it may require a long description of limiting parameters for a more complex device or system having a complicated interface definition.
Standard

METHOD - PRESSURE DROP TESTS FOR FUEL SYSTEM COMPONENTS

1994-09-01
HISTORICAL
ARP868B
To describe useful methods for conducting pressure drop tests of fuel system components for MIL-F-8615 or similar requirements and to present general suggestions for improving accuracy of test results.
Standard

METHOD - PRESSURE DROP TESTS FOR FUEL SYSTEM COMPONENTS

1983-06-01
HISTORICAL
ARP868A
To describe useful methods for conducting pressure drop tests of fuel system components for MIL-F-8615 or similar requirements; and to present general suggestions for improving accuracy of test results.