Vehicle Electromagnetic Immunity--On-Board Transmitter Simulation

2009-08-03
CURRENT
J551/12_200908
This part of SAE J551 specifies on-board transmitter simulation test methods and procedures for testing passenger cars and commercial vehicles. The electromagnetic disturbances considered in this part of SAE J551 are limited to continuous narrow band electromagnetic fields. SAE J551/1 specifies general, definitions, practical use, and basic principles of the test procedure.
Standard

Life Cycle Testing of Electric Vehicle Battery Modules

1997-01-01
HISTORICAL
J2288_199701
This SAE Recommended Practice defines a standardized test method to determine the expected service life, in cycles, of electric vehicle battery modules. It is based on a set of nominal or baseline operating conditions in order to characterize the expected degradation in electrical performance as a function of life and to identify relevant failure mechanisms where possible. Accelerated aging is not included in the scope of this procedure, although the time compression resulting from continuous testing may unintentionally accelerate battery degradation unless test conditions are carefully controlled. The process used to define a test matrix of accelerated aging conditions based on failure mechanisms, and to establish statistical confidence levels for the results, is considered beyond the scope of this document. Because the intent is to use standard testing conditions whenever possible, results from the evaluation of different technologies should be comparable.
Standard

Life Cycle Testing of Electric Vehicle Battery Modules

2008-06-30
CURRENT
J2288_200806
This SAE Recommended Practice defines a standardized test method to determine the expected service life, in cycles, of electric vehicle battery modules. It is based on a set of nominal or baseline operating conditions in order to characterize the expected degradation in electrical performance as a function of life and to identify relevant failure mechanisms where possible. Accelerated aging is not included in the scope of this procedure, although the time compression resulting from continuous testing may unintentionally accelerate battery degradation unless test conditions are carefully controlled. The process used to define a test matrix of accelerated aging conditions based on failure mechanisms, and to establish statistical confidence levels for the results, is considered beyond the scope of this document. Because the intent is to use standard testing conditions whenever possible, results from the evaluation of different technologies should be comparable.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design - Truck and Bus

2008-01-14
HISTORICAL
J2698_200801
1.1 This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids. 1.2 This document is not intended to provide guidance for electric or hybrid electric vehicle wiring circuits. Refer to SAE J1673 for high voltage automotive wiring assembly design. 1.3 Engine block heaters are 120 VAC devices that are used on a multitude of vehicle platforms in addition to trucks with sleeper cabs. Generally, the engine block heater circuit is wired independent of hotel loads.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2018-10-04
CURRENT
J2698_201810
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2014-11-24
HISTORICAL
J2698_201411
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Video

SAE Eye on Engineering: Conti's Smart Backup Camera

2018-11-08
Every year in the U.S., about 300 people die, and 15 thousand vehicles suffer accidents, while backing up. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at Continental's new intelligent backup camera that's small in size but huge in capability. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Standard

R134a Refrigerant Charge Determination Test Method

2018-09-11
CURRENT
J3023_201809
The purpose of this document is to establish guidelines for determining the critical R134a refrigerant charge for off-road, self-propelled work machines as defined in SAE J1116 and Agricultural Tractors as defined in ANSI/ASAE S390. It will develop a minimum to maximum refrigerant charge range in which the HVAC system can maintain proper operation. Operating conditions and characteristics of the equipment will influence the optimum charge. Since these conditions and characteristics vary greatly from one application to another, careful consideration should be taken to determine the optimum R134a refrigerant charge for the HVAC system.
Standard

Heavy Duty OBD IUMPR Data Collection Tool Process

2018-09-04
CURRENT
J3162_201809
This document describes the collection of IUMPR data required by the Heavy Duty On-Board Diagnostic regulation 13 CCR 1971.1 (l)(2.3.3), using SAE J1939-defined messages incorporated in a suite of software functions.