Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

Biomechanical Investigation of Airbag-Induced Upper-Extremity Injuries

1997-11-12
973325
The factors that influence airbag-induced upper-extremity injuries sustained by drivers were investigated in this study. Seven unembalmed human cadavers were used in nineteen direct-forearm-interaction static deployments. A single horizontal-tear-seam airbag module and two different inflators were used. Spacing between the instrumented forearm and the airbag module was varied from 10 cm to direct contact in some tests. Forearm-bone instrumentation included triaxial accelerometry, crack detection gages, and film targets. Internal airbag pressure was also measured. The observed injuries were largely transverse, oblique, and wedge fractures of the ulna or radius, or both, similar to those reported in field investigations. Tears of the elbow joint capsule were also found, both with and without fracture of the forearm.
Technical Paper

Advanced Human Modeling for Injury Biomechanics Research

2003-06-17
2003-01-2223
The two main motivations for Wayne State University (WSU) and Henry Ford Hospital (HFH) researchers to develop numerical human surrogates are advanced computing technology and a high-speed x-ray imaging device not available just a decade ago. This paper summarizes the capabilities and limitations of detailed component models of the human body, from head to foot, developed at WSU over the last decade (Zhang et al. 2001, Yang et al. 1998, Shah et al. 2001, Iwamoto et al. 2000, Lee et al. 2001 and Beillas et al. 2001). All of these models were validated against global response data obtained from relevant high-speed cadaveric tests. Additionally, some models were also validated against local kinematics of bones or soft tissues obtained using the high-speed x-ray system. All of these models have been scaled to conform to the key dimensions of a 50th percentile male.
Technical Paper

Research of Occupant kinematics and Injury values of Hybrid III, THOR, and human FE model in Oblique Frontal Impact

2016-04-05
2016-01-1521
This paper describes impact kinematics and injury values of Hybrid III AM50, THOR AM50 and THUMS AM50 in simulated oblique frontal impact conditions. A comparison was made among them in driver and passenger seat positions of a midsize sedan car finite element (FE) model. The simulation results indicated that the impact kinematics of THOR was close to that of THUMS compared to that of the Hybrid III. Both THOR and THUMS showed z-axis rotation of the rib cage, while Hybrid III did not. It was considered that the rib cage rotation was due primarily to the oblique impact but was allowed by flexibility of the lumbar spine in THOR and THUMS. Lateral head displacement observed in both THOR and THUMS was mostly induced by that rotation in both driver seat and passenger seat positions. The BrIC, thorax and abdominal injury values were close to each other between THOR and THUMS, while HIC15 and Acetabulum force values were different.
Technical Paper

A Study of Driver Injury Mechanism in High Speed Lateral Impacts of Stock Car Auto Racing Using a Human Body FE Model

2011-04-12
2011-01-1104
This paper analyzed the mechanisms of injury in high speed, right-lateral impacts of stock car auto racing, and interaction of the occupant and the seat system for the purpose of reducing the risk of injury, primarily rib fractures. Many safety improvements have been made to stock car racing recently, including the Head and Neck Support devices (HANS®), the 6-point restraint harnesses, and the implementation of the SAFER Barrier. These improvements have contributed greatly to mitigating injury during the race crash event. However, there is still potential to improve the seat structure and the understanding of the interaction between the driver and the seat in the continuation of making racing safety improvements. This is particularly true in the case of right-lateral impacts where the primary interaction is between the seat supports and the driver and where the chest is the primary region of injury.
Technical Paper

Kinematics Response of the PMHS Brain to Rotational Loading of the Head: Development of Experimental Methods and Analysis of Preliminary Data

2018-04-03
2018-01-0547
Experimentally derived brain response envelopes are needed to evaluate and validate existing finite element (FE) head models. Motion of the brain relative to the skull during rotational input was measured using high-speed biplane x-ray. To generate repeatable, reproducible, and scalable data, methods were developed to reduce experimental variance. An “extreme-energy” device was developed to provide a controlled input that is unaffected by specimen characteristics. Additionally, a stereotactic frame was used to deploy radiopaque markers at specific, pre-determined locations within the brain. One post-mortem human surrogate (PMHS) head specimen was subjected to repeat tests of a half-sine rotational speed pulse in the sagittal plane. The desired pulse had a peak angular speed of 40 rad/s and duration of 30 ms. Relative motion of the brain was quantified using radiopaque targets and high-speed biplane x-ray. Frontal and occipital intracranial pressure (ICP) were also measured.
Technical Paper

Development of Side Impact Dummy FE Models using Reverse Engineering

2012-04-16
2012-01-0091
This paper describes the development of dummy FE models to be used for side impact simulations. The precise geometries of the ES-2re dummy and the SID-IIs dummy were measured at a pitch of 1.0 mm using X-ray CT scan. The material properties and the mechanical responses of the components were measured in static and dynamic tests and were used for the model validation. The models were further validated to US-NCAP side impact requirements. Good correlation was seen for both response time history, and to peak deformation values. It is shown that modeling the precise dummy internal structure in addition to the external geometry and applying accurate material properties enabled simulation of deformation kinematics and load transfer inside the dummies. As a result, it was possible to accurately simulate the injury value time histories in an actual test, and understand the mechanisms causing changes to the loading.
Technical Paper

Development of an Advanced ATD Thorax System for Improved Injury Assessment in Frontal Crash Environments

1992-11-01
922520
Injuries to the thorax and abdomen comprise a significant percentage of all occupant injuries in motor vehicle accidents. While the percentage of internal chest injuries is reduced for restrained front-seat occupants in frontal crashes, serious skeletal chest injuries and abdominal injuries can still result from interaction with steering wheels and restraint systems. This paper describes the design and performance of prototype components for the chest, abdomen, spine, and shoulders of the Hybrid III dummy that are under development to improve the capability of the Hybrid III frontal crash dummy with regard to restraint-system interaction and injury-sensing capability.
Technical Paper

Investigation of Upper Body and Cervical Spine Kinematics of Post Mortem Human Subjects (PMHS) during Low-Speed, Rear-End Impacts

2009-04-20
2009-01-0387
A total of eight low-speed, rear-end impact tests using two Post Mortem Human Subjects (PMHS) in a seated posture are reported. These tests were conducted using a HYGE-style mini-sled. Two test conditions were employed: 8 kph without a headrestraint or 16 kph with a headrestraint. Upper-body kinematics were captured for each test using a combination of transducers and high-speed video. A 3-2-2-2-accelerometer package was used to measure the generalized 3D kinematics of both the head and pelvis. An angular rate sensor and two single-axis linear accelerometers were used to measure angular speed, angular acceleration, and linear acceleration of T1 in the sagittal plane. Two high-speed video cameras were used to track targets rigidly attached to the head, T1, and pelvis. The cervical spine kinematics were captured with a high-speed, biplane x-ray system by tracking radiopaque markers implanted into each cervical vertebra.
Technical Paper

Abdominal Impact Response to Rigid-Bar, Seatbelt, and Airbag Loading

2001-11-01
2001-22-0001
This study was conducted to resolve discrepancies and fill in gaps in the biomechanical impact response of the human abdomen to frontal impact loading. Three types of abdominal loading were studied: rigid-bar impacts, seatbelt loading, and close-proximity (out-of-position) airbag deployments. Eleven rigid-bar free-back tests were performed into the mid and upper abdomens of unembalmed instrumented human cadavers using nominal impact speeds of 6 and 9 m/s. Seven fixed-back rigid-bar tests were also conducted at 3, 6, and 9 m/s using one cadaver to examine the effects of body mass, spinal flexion, and repeated testing. Load-penetration corridors were developed and compared to those previously established by other researchers. Six seatbelt tests were conducted using three cadavers and a peak-loading rate of 3 m/s. The seatbelt loading tests were designed to maximize belt/abdomen interaction and were not necessarily representative of real-world crashes.
Technical Paper

Prediction of Airbag-Induced Forearm Fractures and Airbag Aggressivity

2001-11-01
2001-22-0024
This study continued the biomechanical investigations of forearm fractures caused by direct loading of steering-wheel airbags during the early stages of deployment. Twenty-four static deployments of driver airbags were conducted into the forearms of unembalmed whole cadavers using a range of airbags, including airbags that are depowered as allowed by the new federal requirements for frontal impact testing. In general, the depowered airbags showed a reduction in incidence and severity of forearm fractures compared to the pre-depowered airbags tested. Data from these twenty-four tests were combined with results from previous studies to develop a refined empirical model for fracture occurrence based on Average Distal Forearm Speed (ADFS), and a revised value for fifty-percent probability of forearm-bone fracture of 10.5 m/s. Bone mineral content, which is directly related to forearm tolerance, was found to be linearly related to arm mass.
Technical Paper

Recent Advances in Brain Injury Research: A New Human Head Model Development and Validation

2001-11-01
2001-22-0017
Many finite element models have been developed by several research groups in order to achieve a better understanding of brain injury. Due to the lack of experimental data, validation of these models has generally been limited. Consequently, applying these models to investigate brain responses has also been limited. Over the last several years, several versions of the Wayne State University brain injury model (WSUBIM) were developed. However, none of these models is capable of simulating indirect impacts with an angular acceleration higher than 8,000 rad/s2. Additionally, the density and quality of the mesh in the regions of interest are not detailed and sensitive enough to accurately predict the stress/strain level associated with a wide range of impact severities. In this study, WSUBIM version 2001, capable of simulating direct and indirect impacts with a combined translational and rotational acceleration of the head up to 200 g and 12,000 rad/s2 has been developed.
Technical Paper

Investigation of Head Injury Mechanisms Using Neutral Density Technology and High-Speed Biplanar X-ray

2001-11-01
2001-22-0016
The principal focus of this study was the measurement of relative brain motion with respect to the skull using a high-speed, biplanar x-ray system and neutral density targets (NDTs). A suspension fixture was used for testing of inverted, perfused, human cadaver heads. Each specimen was subjected to multiple tests, either struck at rest using a 152-mm-diameter padded impactor face, or stopped against an angled surface from steady-state motion. The impacts were to the frontal and occipital regions. An array of multiple NDTs was implanted in a double-column scheme of 5 and 6 targets, with 10 mm between targets in each column and 80 mm between columns. These columns were implanted in the temporoparietal and occipitoparietal regions. The impacts produced peak resultant accelerations of 10 to 150 g, and peak angular accelerations between 1000 and 8000 rad/s2. For all but one test, the peak angular speeds ranged from 17 to 22 rad/s.
Technical Paper

Brain Strain from Motion of Sparse Markers

2020-03-31
2019-22-0001
Brain strain secondary to head impact or inertial loading is closely associated with pathologic observations in the brain. The only experimental brain strain dataset under loadings close to traumatic levels was calculated by imposing the experimentally measured motion of markers embedded in the brain to an auxiliary model formed by triad elements (Hardy et al., 2007). However, fidelity of the calculated strain as well as the suitability of using triad elements for three-dimensional (3D) strain estimation remains to be verified. Therefore, this study proposes to use tetrahedron elements as a new approach to estimate the brain strain. Fidelity of this newly-proposed approach along with the previous triad-based approach is evaluated with the aid of three independently-developed finite element (FE) head models by numerically replicating the experimental impacts and strain estimation procedures.
Technical Paper

A Reanalysis of Experimental Brain Strain Data: Implication for Finite Element Head Model Validation

2018-11-12
2018-22-0007
Relative motion between the brain and skull and brain deformation are biomechanics aspects associated with many types of traumatic brain injury (TBI). Thus far, there is only one experimental endeavor (Hardy et al., 2007) reported brain strain under loading conditions commensurate with levels that were capable of producing injury. Most of the existing finite element (FE) head models are validated against brain-skull relative motion and then used for TBI prediction based on strain metrics. However, the suitability of using a model validated against brain-skull relative motion for strain prediction remains to be determined. To partially address the deficiency of experimental brain deformation data, this study revisits the only existing dynamic experimental brain strain data and updates the original calculations, which reflect incremental strain changes. The brain strain is recomputed by imposing the measured motion of neutral density target (NDT) to the NDT triad model.
Technical Paper

Brain/Skull Relative Displacement Magnitude Due to Blunt Head Impact: New Experimental Data and Model

1999-10-10
99SC22
Relative motion between the brain and skull may explain many types of brain injury such as intracerebral hematomas due to bridging veins rupture [1] and cerebral contusions. However, no experimental methods have been developed to measure the magnitude of this motion. Consequently, relative motion between the brain and skull predicted by analytical tools has never been validated. In this study, radio opaque markers were placed in the skull and neutral density markers were placed in the brain in two vertical columns in the occipitoparietal and temporoparietal regions. A bi-planar, high-speed x-ray system was used to track the motion of these markers. Due to limitations in current technology to record the x-ray image on high-speed video cameras, only low- speed (﹤ 4m/s) impact data were available.
Technical Paper

Below Knee Impact Responses using Cadaveric Specimens

2004-11-01
2004-22-0004
Knee injuries represent about 10% of all injuries suffered during car crashes. Efforts to assess the injury risk to the posterior cruciate ligament (PCL) have been based on a study available in the literature (Viano et al., 1978), in which only two of the five knees tested had PCL ruptures. The aims of the current study were to repeat the study with a higher number of samples, study the effects of other soft tissues on knee response, and assess the adequacy of the experimental setup for the identification of a PCL tolerance. A total of 14 knees were tested using a high-speed materials testing machine. Eight were intact knees (with the patella and all the muscular and ligamentous structures), three were PCL-only knees (patella and all the muscular and ligamentous structures other than the PCL removed), and the last three were PCL-only knees with the tibia protected from bending fracture.
Technical Paper

A Study of Knee Joint Kinematics and Mechanics using a Human FE Model

2005-11-09
2005-22-0006
Posterior translation of the tibia with respect to the femur can stretch the posterior cruciate ligament (PCL). Fifteen millimeters of relative displacement between the femur and tibia is known as the Injury Assessment Reference Value (IARV) for the PCL injury. Since the anterior protuberance of the tibial plateau can be the first site of contact when the knee is flexed, the knee bolster is generally designed with an inclined surface so as not to directly load the projection in frontal crashes. It should be noted, however, that the initial flexion angle of the occupant knee can vary among individuals and the knee flexion angle can change due to the occupant motion. The behavior of the tibial protuberance related to the knee flexion angle has not been described yet. The instantaneous angle of the knee joint at the timing of restraining the knee should be known to manage the geometry and functions of knee restraint devices.
Technical Paper

Interactions of Out-of-Position Small-Female Surrogates with a Depowered Driver Airbag

2008-11-03
2008-22-0008
The objectives of this study were to examine the response, repeatability, and injury predictive ability of the Hybrid III small-female dummy to static out-of-position (OOP) deployments using a depowered driver-side airbag. Five dummy tests were conducted in two OOP configurations by two different laboratories. The OOP configurations were nose-on-rim (NOR) and chest-on-bag (COB). Four cadaver tests were conducted using unembalmed small-female cadavers and the same airbags used in the dummy tests under similar OOP conditions. One cadaver test was designed to increase airbag loading of the face and neck (a forehead-on-rim, or FOR test). Comparison between the dummy tests of Lab 1 and of Lab 2 indicated the test conditions and results were repeatable. In the cadaver tests no skull fractures or neck injuries occurred. However, all four cadavers had multiple rib fractures.
Technical Paper

A Study of the Response of the Human Cadaver Head to Impact

2007-10-29
2007-22-0002
High-speed biplane x-ray and neutral density targets were used to examine brain displacement and deformation during impact. Relative motion, maximum principal strain, maximum shear strain, and intracranial pressure were measured in thirty-five impacts using eight human cadaver head and neck specimens. The effect of a helmet was evaluated. During impact, local brain tissue tends to keep its position and shape with respect to the inertial frame, resulting in relative motion between the brain and skull and deformation of the brain. The local brain motions tend to follow looping patterns. Similar patterns are observed for impact in different planes, with some degree of posterior-anterior and right-left symmetry. Peak coup pressure and pressure rate increase with increasing linear acceleration, but coup pressure pulse duration decreases. Peak average maximum principal strain and maximum shear are on the order of 0.09 for CFC 60 Hz data for these tests.
Technical Paper

Correlation of Strain and Loads Measured in the Long Bones With Observed Kinematics of the Lower Limb During Vehicle-Pedestrian Impacts

2007-10-29
2007-22-0018
The purpose of this study is to determine the loads in the long bones of the lower extremities during vehicle pedestrian impact tests, and to correlate load data with observed kinematics in an effort to understand how stature and vehicle shape influence pedestrian response. In tests with a large sedan and a small multi-purpose vehicle (MPV), four postmortem human surrogates (PMHS) in mid-stance gait were struck laterally at 40 km/h. Prior to the tests, each PMHS was instrumented with four uniaxial strain gages around the mid-shaft cross section of the struck-side (right) tibia and the femora bilaterally. After the tests, the non-fractured bones were harvested and subjected to three-point bending experiments. The effective elastic moduli were determined by relating the applied bending loads with the measured strains using strain gage locations, detailed bone geometry, and elastic beam theory.
X