Refine Your Search

Topic

Search Results

Standard

Temperature Instruments (Reciprocating Engine Powered Aircraft)

2008-02-16
CURRENT
AS413B
This Aerospace Standard covers two basic types of temperature instruments as follows: TYPE I: Ratiometer type, actuated by changes in electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. TYPE II: Millivoltmeter type, operated and actuated by varying E.M.F. output of a thermocouple; the varying E.M.F. input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TEMPERATURE INDICATOR

1954-12-01
HISTORICAL
AS413A
This Aeronautical Standard covers two basic types of temperature indicators as follows: TYPE I - Ratiometer type actuated by changes of electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. TYPE II - Millivoltmeter type, operated and actuated by varying e.m.f. output of a thermocouple, the varying e.m.f. input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TEMPERATURE INSTRUMENTS (TURBINE POWERED SUBSONIC AIRCRAFT)

2008-02-16
CURRENT
AS414B
This SAE Aerospace Standard (AS) covers two basic types of temperature instruments as follows: Type I: Ratiometer type, actuated by changes in electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. Type II: Millivoltmeter type, operated and actuated by varying EMF output of a thermocouple; the varying EMF input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TEMPERATURE INDICATOR

1948-11-01
HISTORICAL
AS413
This specification covers two types of instruments. These instruments are for the purpose of measuring temperature, such as those of oil coolant, carburetor air, free air and cylinder head.
Standard

TRUE MASS FUEL FLOW INSTRUMENTS

1962-02-01
HISTORICAL
AS431A
This Aerospace Standard covers three basic types of true mass flow indicating instruments. Each may consist of an indicator, transmitter and other auxiliary means such as a power supply or amplifier as required.
Standard

TRUE MASS FUEL FLOW INSTRUMENTS

2008-02-16
CURRENT
AS431B
This SAE Aerospace Standard (AS) covers three basic types of true mass flow indicating instruments. Each may consist of an indicator, transmitter and other auxiliary means such as a power supply or amplifier as required.
Standard

DIRECTIONAL INDICATING SYSTEM (TURBINE POWERED SUBSONIC AIRCRAFT)

1991-05-01
HISTORICAL
ARP416
This recommended practice covers the requirements for gyroscopically stabilized Directional Indicating Systems, which will operate as a 1°/hour latitude corrected, free directional gyro or as a slaved gyro, magnetic compass with 1/2° accuracy.
Standard

Directional Indicating System (Turbine Powered Subsonic Aircraft)

2008-02-16
HISTORICAL
ARP416A
This recommended practice covers the requirements for gyroscopically stabilized Directional Indicating Systems, which will operate as a 1°/hour latitude corrected, free directional gyro or as a slaved gyro, magnetic compass with 1/2° accuracy.
Standard

Exhaust Gas Temperature Instruments

2008-02-16
CURRENT
AS428
The exhaust gas temperature instruments covered by this standard are of the electrical servo null balance type, actuated by a varying emf output of one or more parallel connected Chromel-Alumel thermocouples.
Standard

Overspeed Warning Instrument (Turbine Powered Subsonic Aircraft)

2008-02-16
CURRENT
ARP435
This ARP covers an electro-mechanical pneumatic device which is calibrated to provide control contacts that can be made to operate a warning device whenever the indicated airspeed (IAS) reaches a maximum value as defined by the operating limit speed curve for the specific model aircraft.
Standard

Barometry for Altimeter Calibration

2020-02-20
CURRENT
AIR1075B
This SAE Aerospace Information Report (AIR) is concerned only with aspects directly relating to available accuracy. While well-designed photoelectric, inductive or capacitive readers and pressure regulators, and other accessories are highly desirable for convenience and production rate, they are considered to be outside the scope of this AIR.
Standard

Pressure Ratio Instruments

2008-02-16
CURRENT
ARP427A
This Aeronautical Recommended Practice covers two types of two unit Pressure Ratio Instruments each of which consist of a Transducer and an Indicator. The Transducer computes the ratio of two pressures and converts this ratio to a synchro electrical signal which is transmitted to the Indicator.
Standard

PRESSURE RATIO INSTRUMENTS

1991-05-01
HISTORICAL
ARP427
This Aeronautical Recommended Practice covers two types of two unit Pressure Ratio Instruments each of which consist of a Transducer and an Indicator. The Transducer computes the ratio of two pressures and converts this ratio to a synchro electrical signal which is transmitted to the Indicator.
Standard

Manifold Pressure Indicating Instruments

2008-02-16
CURRENT
AS411B
This Aerospace Standard covers two basic types of manifold pressure instruments as follows: Type I - Direct Indicating Type II - Remote Indicating
Standard

MANIFOLD PRESSURE INDICATING INSTRUMENTS

1993-05-01
HISTORICAL
AS411A
This Aerospace Standard covers two basic types of manifold pressure instruments as follows: Type I - Direct Indicating Type II - Remote Indicating
Standard

CARBON MONOXIDE DETECTOR INSTRUMENTS

1991-05-01
HISTORICAL
AS412A
This Aeronautical Standard covers the basic type of carbon monoxide detector instrument used to determine toxic concentrations of carbon monoxide by the measurement of heat changes through catalytic oxidation.
Standard

CARBON MONOXIDE DETECTORS, (SIGNAL ASSEMBLY)

1948-11-01
HISTORICAL
AS412
This specification covers the basic type of instrument for detection of toxic concentrations of carbon monoxide whose operation is based on measurement of heat changes through catalytic oxidation.
X