Technical Paper

Technical Review: Comparison of IC and CE for Monitoring Ionic Water Contaminants on SSF

1991-07-01
911438
The measurement of ionic contaminants in samples from the potable water system on Space Station Freedom is one of the basic functions of the Crew Health Care System (CHeCS). The U. S. Environmental Protection Agency has identified ion chromatography as the analytical method of choice for measurement of anions and cations in water as described in USEPA method numbers 300.0 and 300.7, respectively. For this reason, ion chromatography was the technology initially identified to perform the ion contaminant monitoring function in the CHeCS Water Quality Subsystem. Subsequently, mass, size, and maintenance restrictions have led to a reevaluation of method options. Capillary electrophoresis (CE) has emerged as one of the more promising alternatives. CE is inherently microgravity compatible and uses an order of magnitude less reagent volume than ion chromatography. The major drawback to CE is its present state of development.
Technical Paper

Updated Systems for Water Recovery from Humidity Condensate and Urine for the International Space Station

1997-07-14
972559
At the initial phase of the construction of the international space station (ISS) water supply will be provided by the systems located in the Russian segment. The paper reviews the systems for water recovery from humidity condensate and urine to be incorporated in the Russian segment of the ISS. The similar systems have been successfully operated on the Mir space station. The updates aim at enhancing system cost-effectiveness and reliability. The system for water recovery from humidity condensate (WRS-C) features an added assembly for the removal of organic contaminants to be catalytically oxidized in an air/liquid flow at ambient temperature and pressure. The system for water reclamation from urine (WRS-U) incorporates a new distillation subsystem based on vacuum distillation with a multistage rotary distiller and a vapor compression or thermoelectric heat pump. The updating of the WRS-C system will enable an increase in the multifiltration bed's life at least two fold.
Technical Paper

Capillary Electrophoresis for Spacecraft Drinking Water Analysis: Methods and Breadboard Development

1997-07-01
972464
This report describes the first two parts of a three-phase project to develop and test a spacecraft-compatible capillary electrophoresis (CE) instrument. This instrument is designed to monitor the quality of recycled potable water aboard spacecraft such as the International Space Station. Phase I involved selecting and validating methods for low mass-to-charge ratio (m/z) cations and anions by using a slightly modified commercial CE instrument as a model. The analytical performance of several published CE methods was assessed for their ability to detect targeted anions and cations listed in a NASA water quality standard. Direct and indirect UV absorption detection at a single wavelength (214 nm) was used, and separation selectivity and sensitivity were optimized at the expense of analysis time. Phase II focused on building a breadboard CE instrument and flight-testing it on NASA's KC-135 parabolic aircraft.
Technical Paper

Potable Water Treatment and Transfer from Shuttle to Mir

1997-07-01
972461
To satisfy a requirement to supply water to Mir station, a process for treating iodinated water on the Shuttle was developed and implemented. The treatment system consists of packed columns for removing iodine and a syringe-based injection system for adding ionic silver, the biocide used in Mir water. Technical and potable grade water is produced and transferred in batches using collapsible 44-liter contingency water containers (CWCs). Silver is added to the water via injection of a solution from preloaded syringes. Minerals are also added to water destined for drinking. During the previous four Shuttle-Mir docking missions a total of 2781 liters (735 gallons) of water produced by the Shuttle fuel cells was processed using this method and transferred to Mir. To verify the quality of the processed water, samples were collected during flight and returned for chemical analysis.
Technical Paper

Rationale and Selection of a Distillation Subsystem for Water Reclamation from Urine

1998-07-13
981714
A selection of a distillation subsystem with a rotary multistage vacuum distiller (RMVD) and a heat pump (HP) for the system for water reclamation from urine for the international space station is substantiated. The results of computational/experimental analysis of specific energy for distillation with RMVD and HP of different type used are presented. The test results of an experimental system mockup are given. It is shown that the subsystem of a given type is stable in operation, features high condensate processing rate and low specific energy demand.
Technical Paper

Humidity Condensate Sampling System for Shuttle, Mir and International Space Station

1998-07-13
981764
Archival sampling of potable water and condensate for ground laboratory analysis has been an important part of the Shuttle-Mir program because of coolant leaks and other events on Mir that have affected water quality. We report here the development of and preliminary results from a novel device for single phase humidity condensate collection at system pressures. The sampler consists of a commercial-off-the-shelf Teflon® bladder and a custom reinforced Nomex® restraint that is sized properly to absorb the stress of applied pressures. A plastic Luer-Lock disconnect, with poppet actuated by a mating Luer-Lock fitting, prevents the contents from being spilled during transport. In principle, a sampler of any volume can be designed. The empty mass of the reusable one-liter sampler is only 63 grams. Several designs were pressure tested and found to withstand more than 3 atmospheres well in excess of typical spacecraft water or wastewater system pressures.
Technical Paper

ISS Potable Water Sampling and Chemical Analysis: Expeditions 4 & 5

2003-07-07
2003-01-2401
The International Space Station (ISS) drinking water supply consists of water recovered from humidity condensate, water transferred from Shuttle, and groundwater supplied from Russia. The water is dispensed from both the stored water dispensing system (SVO-ZV) and the condensate recovery system (SRV-K) galley. Teflon bags are used periodically to collect potable water samples, which are then transferred to Shuttle for return to Earth. The results from analyses of these samples are used to monitor the potability of the drinking water on board and evaluate the efficiency of the water recovery system. This report provides results from detailed analyses of samples of ISS recovered potable water, Shuttle-supplied water, and ground-supplied water taken during ISS Expeditions 4 and 5. During Expedition 4, processing of U.S. Lab condensate through the Russian condensate recovery system was initiated. Results indicate water recovered from both Service Module and U.S.
Technical Paper

Water Recovery and Urine Collection Abord the International Space Station

2003-07-07
2003-01-2622
The paper deals with the performance data of the service module Zvezda water supply and urine collection systems of the International Space Station (ISS) as of December 31, 2002. The water supply and demand balance are analyzed. The data of humidity condensate and recovered water compositions are reviewed. The effective cooperation of the international partners on part of life support is shown.
Technical Paper

Water Recovery and Urine Collection in the Service Module of the International Space Station

2001-07-09
2001-01-2355
The paper deals with the construction and performance data of the service module Zvezda water supply system of the International Space Station (ISS). The performance data at an initial phase of manned station functioning are provided. The data on humidity condensate and recovered water composition are reviewed. The water supply and demand balance are analyzed. The effective cooperation of international partners on part of water supply for the crew is shown.
Technical Paper

Chemical Sampling and Analysis of ISS Potable Water: Expeditions 1-3

2002-07-15
2002-01-2537
The early International Space Station (ISS) drinking water supply primarily consists of water recovered from humidity condensate and water transferred from Shuttle. The water is dispensed both from the stored water dispensing system (SVO-ZV) and the galley, which is an integral part of the condensate recovery system. The galley provides both hot and tepid water. An assessment of the quality of each potable water source is underway and consists of periodic collection of samples into Teflon® bags for return to Earth via Shuttle. Water sampling hardware and procedures developed and used during the Shuttle-Mir program are employed on ISS without significant changes. This report provides results from detailed chemical analyses of recovered potable water and supplied (stored) water samples returned from ISS Expeditions 1 through 3. These results have been used to monitor the potability of the product and stored drinking water by comparing the results against water quality standards.
Technical Paper

Quality of Water Supplied by Shuttle to ISS

2002-07-15
2002-01-2532
The water supply for the International Space Station (ISS) consists partially of excess fuel-cell water that is treated on the Shuttle and stored on ISS in 44 L collapsible Contingency Water Containers (CWCs). Iodine is removed from the source water, and silver biocide and mineral concentrates are added by the crewmember while the CWCs are filled. Potable (mineralized) CWCs are earmarked for drinking and food hydration, and technical (non-mineralized) CWCs are reserved for waste system flushing and electrolytic oxygen generation. Representative samples are collected in Teflon® bags and returned to Earth for chemical analysis. The parameters typically measured include pH, conductivity, total organic carbon, iodine, silver, calcium, magnesium, fluoride, trace metals, formate and alcohols. The Nylon monomer caprolactam is also measured and tracked since it is known to leach slowly out of the plastic CWC bladder material.
Technical Paper

Water Recovery and Oxygen Generation by Electrolysis Aboard the International Space Station

2002-07-15
2002-01-2358
The paper deals with the construction and performance data of the service module Zvezda water and oxygen supply systems of the International Space Station (ISS). The performance data at the first 14 months of manned station functioning are provided. The data of humidity condensate and recovered water compositions are reviewed. The water supply and demand balance are analyzed. The system of oxygen generation “Electron-VM” and its functioning results are reviewed. The effective cooperation of the international partners on part of life support is shown.
Technical Paper

Chemical Characterization of U.S. Lab Condensate

2006-07-17
2006-01-2016
Approximately 50% of the water consumed by International Space Station crewmembers is water recovered from cabin humidity condensate. Condensing heat exchangers in the Russian Service Module (SM) and the United States On-Orbit Segment (USOS) are used to control cabin humidity levels. In the SM, humidity condensate flows directly from the heat exchanger to a water recovery system. In the USOS, a metal bellows tank located in the US Laboratory Module (LAB) collects and stores condensate, which is periodically off-loaded in about 20-liter batches to Contingency Water Containers (CWCs). The CWCs can then be transferred to the SM and connected to a Condensate Feed Unit that pumps the condensate from the CWCs into the water recovery system for processing. Samples of the condensate in the tank are collected during the off-loads and returned to Earth for analyses.
Technical Paper

A Physical/Chemical System for Water and Atmosphere Recovery Aboard a Space Station

1993-07-01
932077
The paper deals with the problems of development of physico-chemical systems for water recovery and atmosphere revitalization for long-duration space stations. Schematics of regenerative life support systems featuring a high degree of closure and biotechnological components are presented. A year-long experiment has proved the possibility for Man to stay in a closed artificial environment for a long time by consuming substances regenerated by physico-chemical means from the end products of life. A complex of the life support systems (LSS) on Mir space station allowing for oxygen and 90% water recovery as well as its future updating is considered.
Technical Paper

Hydrodynamic and Heat-and-Mass Transfer Processes in Space Station Water Recovery Systems

1993-07-01
932075
The paper systematizes typical hydrodynamic and heat-and-mass transfer chemical engineering processes realized in water recovery systems. The impact of micro-gravity on the processes is analyzed and general principles of the process organization in gas/liquid fluids are described. As examples, some typical separation processes in a coccurred flow channel with liquid suction through a porous wall, liquid evaporation into a vapour/gas fluid and vapour condensation from the vapour/gas mixture are considered for water recovery systems. A versatile approach based on an extended analogy between friction, heat transfer and mass transfer and on limited relative laws of a boundary layer at the permeable surface is suggested for an analysis and calculation of the friction resistance of a two-phase flow, heat transfer and mass transfer on evaporation and condensation. Recommendations for an analysis of the influence of free convection are made.
Technical Paper

Evaluation of Capillary Electrophoresis for In-flight Ionic Contaminant Monitoring of SSF Potable Water

1992-07-01
921268
Until 1989, ion chromatography (IC) was the baseline technology selected for the Specific Ion Analyzer, an in-flight inorganic water quality monitor being designed for Space Station Freedom. Recent developments in capillary electrophoresis (CE) may offer significant savings of consumables, power consumption, and weight/volume allocation, relative to IC technology. A thorough evaluation of CE's analytical capability, however, is necessary before one of the two techniques is chosen. Unfortunately, analytical methods currently available for inorganic CE are unproven for NASA's target list of anions and cations. Thus, CE electrolyte chemistry and methods to measure the target contaminants must be first identified and optimized. This paper reports the status of a study to evaluate CE's capability with regard to inorganic and carboxylate anions, alkali and alkaline earth cations, and transition metal cations.
Technical Paper

Biofilm Formation and Control in a Simulated Spacecraft Water System: Three Year Results

1992-07-01
921310
Two simulated spacecraft water systems are being used to evaluate the effectiveness of iodine for controlling microbial contamination within such systems. An iodine concentration of about 2.0 mg/L is maintained in one system by passing ultrapure water through an iodinated ion exchange resin. Stainless steel coupons with electropolished and mechanically-polished sides are being used to monitor biofilm formation. Results after three years of operation show a single episode of significant bacterial growth in the iodinated system when the iodine level dropped to 1.9 mg/L. This growth was apparently controlled by replacing the iodinated ion exchange resin, thereby increasing the iodine level. The second batch of resin has remained effective in controlling microbial growth down to an iodine level of 1.0 mg/L. Scanning electron microscopy indicates that the iodine has impeded but may have not completely eliminated the formation of biofilm.
Technical Paper

Systems for Water Reclamation from Humidity Condensate and Urine for Space Station

1994-06-01
941536
This paper deals with water reclamation from humidity condensate and urine schematics and processes realized on orbital space stations Salut and Mir. The results of research in updated processes and schematics for condensate separation, purification and distillation with heat energy recovery are described. It is shown that the processes and hardware make possible to reduce energy demand and the weight of the water recovery systems under operation on space stations.
Technical Paper

GC/MS and CE Methods for the Analysis of Trace Organic Acids in Reclaimed Water Supplies

1994-06-01
941392
The objective of this study was to investigate combining GC/MS and CE methods to allow sub-mg/L levels of organic acids to be determined in various water samples. This study also served as a basis for evaluating these instruments for in-flight spacecraft water-quality monitoring and to help determine the modifications needed to convert terrestrial hardware for use in microgravity environments. This paper reports on current GC/MS and CE method development and data generated from some recent spacecraft-related water samples. Plans for further method development are also discussed.
Technical Paper

Depletion of Biocidal Iodine in a Stainless Steel Water System

1994-06-01
941391
Iodine depletion in a simulated water storage tank and distribution system was examined to support a larger research program aimed at developing disinfection methods for spacecraft potable water systems. The main objective of this study was to determine the rate of iodine depletion with respect to the surface area of the stainless steel components contacting iodinated water. Two model configurations were tested. The first, representing a storage and distribution system, consisted of a stainless steel bellows tank, a coil of stainless steel tubing and valves to isolate the components. The second represented segments of a water distribution system and consisted of eight individual lengths of 21-6-9 stainless tubing similar to that used in the Shuttle Orbiter. The tubing has a relatively high and constant surface area to volume ratio (S/V) and the bellows tank a lower and variable S/V.