The test procedure applies to the refueling manifold system connecting the receiver aircraft fuel tanks to the refueling source fuel pump(s) for both ground and aerial refueling. The test procedure is intended to verify that the limit value for surge pressure specified for the receiver fuel system is not exceeded when refueling from a refueling source which meets the requirements of AS1284 (reference 2). This recommended practice is not directly applicable to surge pressure developed during operation of an aircraft fuel system, such as initiating or stopping engine fuel feed or fuel transfer within an aircraft, or the pressure surge produced when the fuel pumps are first started to fill an empty fuel manifold.
To describe general guidelines for achieving selected levels of cleanliness in gas turbine engine fuel system components and to describe laboratory methods for measuring and reporting the contamination level of the wetted portion of fuel system components. As in SAE J1227 (covering hydraulic components) this practice includes guidelines for levels of acceptance but does not attempt to set those levels.
This report is intended to identify the necessary analytical tools to enable making value judgments for minimizing the various errors typically encountered in capacitance systems. Thus, in addition to identification of error sources, it describes the basic factors which cause the errors. When coupled with appraisals of the relative costs of minimizing the errors, this knowledge will furnish a tool with which to optimize gauging system accuracy, and thus, to obtain the optimum overall system within the constraints imposed by both design and budgetary considerations. Since the subject of capacitance accuracy is quite complex, no attempt is made herein to present a fully-comprehensive evaluation of all factors affecting gauging system accuracy. Rather, the major contributors to gauging system inaccuracy are discussed and emphasis is given to simplicity and clarity, somewhat at the expense of completeness. An overview of Capacitive Fuel Gauging operation is provided in the Appendix.
This SAE Aerospace Information Report (AIR) discusses the impact of the ISO Test Dusts, chosen as replacement contaminants for the Arizona Test Dusts (AC Test Dusts), and the ISO calibration procedure ISO 11171 for automatic particle counters, which replaces the calibration procedure ISO 4402 (1991), on laboratory performance of filter elements utilized in aerospace lubrication, hydraulic and fuel systems, and fluid cleanliness levels determined with automatic particle counters.
This SAE Aerospace Information Report (AIR) discusses the impact of the ISO Test Dusts, chosen as replacement contaminants for the Arizona Test Dusts (AC Test Dusts), and the ISO calibration procedure ISO 11171 for automatic particle counters, which replaces the calibration procedure ISO 4402 (1991), on laboratory performance of filter elements utilized in aerospace lubrication, hydraulic and fuel systems, and fluid cleanliness levels determined with automatic particle counters.
This project aims to develop a framework of requirements which support safe installation and operation of optical devices within an aircraft fuel tank, specifically: 1: To determine optical power and energy limits which ensure safe operation of optical installations within an aircraft fuel tank over aircraft life and under all phases of flight, taking the limits provided in IEC 60079-28:20015 as a starting point. 2: To demonstrate optical and electrical power and energy equivalences, where possible. 3: To determine requirements for optical installations, including bonding and electrostatic discharge for non-conductive components such as optical fibres. 4: To provide guidelines for analysis of the hazards presented by the typical internal components of optical devices, such as failure modes of photo diodes and cells.
The scope of this document is to provide pertinent information on demonstrating the performance of Flame Arrestors, also known as Fuel Vent Protectors (FVPs), in preventing the propagation of a deflagration when the arrestors are subjected to aerospace-representative flames produced by the venting of flammable gas through the arrestor. Test procedures for two separate combustion-loading profiles are presented herein: The flame hold test condition, and the flame propagation test condition. For the flame hold test condition, the applicability of two separate critical flows is discussed in which one flow results in the greatest flame arrestor temperature and a second flow results in the greatest temperature of the surrounding structure.
The test procedure applies to the refueling manifold system connectingn the receiver aircraft fuel tanks to the refueling source fuel pump(s) for both ground and aerial refueling. The test procedure is intended to verify that the limit value for surge pressure specified for the receiver fuel system is not exceeded when refueling from a refueling source which meets the requirements of AS1284 (reference 2). This recommended practice is not directly applicable to surge pressure developed during operation of an aircraft fuel system, such as initiating or stopping engine fuel feed or fuel transfer within an aircraft, or the pressure surge produced when the fuel pumps are first started to fill an empty fuel manifold.
This SAE Aerospace Information Report (AIR) reviews performance testing parameters for noncleanable, often referred to as disposable, aircraft gas turbine engine lubricant filter elements.
This Aerospace Standard (AS) defines maximum free opening dimensions for airframe refueling ports on civil aircraft that require the exclusive use of aviation gasolines, and minimum free opening dimensions for airframe refueling ports on civil aircraft that operate with turbine fuels as a primary fuel type. In addition, this document defines the minimum refueling nozzle tip dimensions for turbine fuels ground service equipment, and the maximum refueling nozzle tip diameter dimension for aviation gasolines ground service equipment.
This AS defines maximum free opening dimensions for airframe refueling ports on civil aircraft that require the exclusive use of aviation gasolines, and minimum free opening dimensions for airframe refueling ports on civil aircraft that operate with turbine fuels as a primary fuel type. In addition, this document defines the minimum refueling nozzle tip dimensions for turbine fuels ground service equipment, and the maximum refueling nozzle tip diameter dimension for aviation gasolines ground service equipment.
This SAE Aerospace Standard (AS) defines the maximum allowable free opening dimensions for airframe fueling ports on civil aircraft that require the exclusive use of gasoline as an engine fuel and the minimum free opening dimensions for airframe fueling ports on civil aircraft that operate with turbine fuels as the primary fuel type. In addition, this document defines the minimum fuel nozzle tip dimensions for turbine fuel ground service equipment and the maximum fuel nozzle tip diameter for gasoline ground service equipment.
This SAE Aerospace Standard (AS) defines the maximum allowable free opening dimensions for airframe fueling ports on civil aircraft that require the exclusive use of gasoline as an engine fuel, and the minimum free opening dimensions for airframe fueling ports on civil aircraft that operate with turbine fuels as the primary fuel type and with gasoline as the emergency fuel type. This SAE Aerospace Standard (AS) also defines the features and dimensions for airframe refueling ports on civil aircraft that require the exclusive use of turbine fuel as an engine fuel. In addition, this document defines the minimum fuel nozzle spout dimensions for turbine fuel ground service equipment, and the maximum fuel nozzle spout diameter for gasoline ground service equipment.