Refine Your Search

Search Results

Viewing 1 to 7 of 7
Technical Paper

Simulation of Cooling Airflow under Different Driving Conditions

2007-04-16
2007-01-0766
Presented are simulations of cooling airflow and external aerodynamics over Land Rover LR3 and Ford Mondeo cars under several driving conditions. The simulations include details of the external flow field together with the flow in the under-hood and underbody areas. Shown is the comparison between the predicted and measured coolant inlet temperature in the radiator, drag and lift coefficients, temperature distribution on the radiator front face, and wake total pressure distribution. Very good agreement is observed. In addition, shown is the complex evolution of the temperature field in the idle case with strong under-hood recirculation. It is shown that the presented Lattice-Boltzmann Method based approach can provide accurate predictions of both cooling airflow and external aerodynamics.
Technical Paper

Long Term Transient Cooling of Heavy Vehicle Cabin Compartments

2010-10-05
2010-01-2018
A newly developed simulation methodology for a long term, transient tractor cabin cool-down is presented in this paper. The air flow was simulated using a Lattice-Boltzmann Equation (LBE) based 3-dimensional flow solver. The conduction and radiation effects on the solid parts as well as the average cabin air temperature evolution were solved by the thermal solver, which also includes a human comfort model. The simulation results were compared with the measured experimental test data and good agreement was observed validating the developed simulation approach. The developed methodology can be applied to all other ground vehicles cabin comfort applications.
Technical Paper

Transient Simulation of DGI Engine Injector with Needle Movement

2002-10-21
2002-01-2663
Utilization of direct injection systems is one of the most promising technologies for fuel economy improvement for SI engine powered passenger cars. Engine performance is essentially influenced by the characteristics of the injection equipment. This paper will present CFD analyses of a swirl type GDI injector carried out with the Multiphase Module of AVL's FIRE/SWIFT CFD code. The simulations considered three phases (liquid fuel, fuel vapor, air) and mesh movement. Thus the transient behavior of the injector can be observed. The flow phenomena known from measurement and shown by previous simulation work [2, 7, 10, 11] were reproduced. In particular the simulations shown in this paper could explain the cause for the outstanding atomization characteristics of the swirl type injector, which are caused by cavitation in the nozzle hole.
Technical Paper

DVE - Direct Vehicle Exhaust Flow Measurement using Head-type Flowmeters

2003-03-03
2003-01-0782
When exhaust emissions from a vehicle are measured, a flow rate is needed in addition to pollutant concentrations in order to calculate the mass emitted. The highly unsteady flow from an internal combustion engine presents measurement challenges to exhaust flowmeters, especially at idle. Mass measurement methods used in the past have gotten around this problem by a variable dilution scheme (CVS) that measures a different, more favorable flow, but reduces and can contaminate exhaust gas concentration levels. The flow measurement system described here makes possible a more accurate measure of the vehicle exhaust flow by means of a number of design features. This improves considerably the cost effectiveness and accuracy of emissions measurement techniques such as the Bag-Minidiluter sampling system and raw modal analysis.
Technical Paper

Numerical Simulation of Transient Thermal Convection of a Full Vehicle

2011-04-12
2011-01-0645
Many critical thermal issues that occur in vehicles are uncovered only under more “thermally stressed” driving conditions that are transient in nature such as abruptly changing vehicle speed or turning off fan and engine. Therefore, for flow simulations to be useful in the vehicle design process, it is imperative that these simulations have the ability to accurately model long term transient thermal convection on full vehicles. Presented are simulations for a passenger vehicle driving at 60 kilometers per hour followed by a complete stop. The simulations were performed using a coupling between the flow and thermal solver and in the process, taking into account convection, conduction and radiation effects. Temperature predictions were made both under steady state conditions and during the key-off. Good agreement with the measurements was observed.
Technical Paper

Update on A-Pillar Overflow Simulation

2018-04-03
2018-01-0717
The management of surface water flows driven from the wind screen by the action of wipers and aerodynamic shear is a growing challenge for automotive manufacturers. Pressure to remove traditional vehicle features, such as A-Pillar steps for aesthetic, aeroacoustic and aerodynamic reasons increases the likelihood that surface water may be convected over the A-Pillar and onto the front side glass where it can compromise drivers’ vision. The ability to predict where and under which conditions the A-Pillar will be breached is important for making correct design decisions. The use of numerical simulation in this context is desirable, as experimental testing relies on the use of aerodynamics test properties which will not be fully representative, or late-stage prototypes, making it difficult and costly to correct issues. This paper provides an update on the ability of simulation to predict A-Pillar overflow, comparing physical and numerical results for a test vehicle.
Technical Paper

DIGITAL PHYSICS™ Analysis of the Morel Body in Ground Proximity

1997-02-24
970139
Presented is a study of the air flow over the Morel body [1] in ground proximity which was obtained using a discrete particle method, referred to as DIGITAL PHYSICS. The results were computed at several back-light angles and will be compared to experimental observations. Separation and reattachment along the angled section at a back-light angle of 30 degrees, and complete separation at 35 degrees, were both accurately predicted.