Design of a Laboratory Sampling System for Brake Wear Particle Measurements

2022-09-19
2022-01-1179
Brake wear is one of the dominant sources of traffic-related particulate matter emissions and is associated with various adverse environmental and health hazards. To address this issue, the UNECE mandated the Particle Measurement Program to develop a harmonized methodology for sampling and measuring brake wear particles with a full-flow sampling tunnel on a brake dynamometer. Here we present the design of a novel, fully PMP compliant sampling tunnel. The dimensions and general layout of the tunnel are based on minimization of super-micron particle losses and consideration of space limitations in brake-dynamometer setups as well as the need for efficient utilization of the test facilities (reduced testing times). Numerical calculations suggested that the critical section of the system is the sampling train from the sample probes to the instrumentation inlet/filter holder.