Refine Your Search

Search Results

Viewing 1 to 6 of 6
Journal Article

Catalytic Soot Oxidation: Effect of Ceria-Zirconia Catalyst Particle Size

2016-04-05
2016-01-0968
Catalysts that have been extensively investigated for direct soot oxidation in Catalyzed Diesel Particulate Filters (CDPFs) are very often based on mixed oxides of ceria with zirconia, materials known to assist soot oxidation by providing oxygen to the soot through an oxidation-reduction catalytic cycle. Besides the catalyst composition that significantly affects soot oxidation, other parameters such as morphological characteristics of the catalyst largely determined by the synthesis technique followed, as well as the reagents used in the synthesis may also contribute to the activity of the catalysts. In the present work, two ceria-zirconia catalyst samples with different zirconia content were subjected to different milling protocols with the aim to shift the catalyst particle size distribution to lower values. The produced catalysts were then evaluated with respect to their soot oxidation activity following established protocols from previous works.
Journal Article

Investigation of SCR Catalysts for Marine Diesel Applications

2017-03-28
2017-01-0947
Evolving marine diesel emission regulations drive significant reductions of nitrogen oxide (NOx) emissions. There is, therefore, considerable interest to develop and validate Selective Catalytic Reduction (SCR) converters for marine diesel NOx emission control. Substrates in marine applications need to be robust to survive the high sulfur content of marine fuels and must offer cost and pressure drop benefits. In principle, extruded honeycomb substrates of higher cell density offer benefits on system volume and provide increased catalyst area (in direct trade-off with increased pressure drop). However higher cell densities may become more easily plugged by deposition of soot and/or sulfate particulates, on the inlet face of the monolithic converter, as well as on the channel walls and catalyst coating, eventually leading to unacceptable flow restriction or suppression of catalytic function.
Journal Article

Experimental Study of Thermal Aging on Catalytic Diesel Particulate Filter Performance

2013-04-08
2013-01-0524
In this paper, a methodology is presented to study the influence of thermal aging on catalytic DPF performance using small scale coated filter samples and side-stream reactor technology. Different mixed oxide catalytic coating families are examined under realistic engine exhaust conditions and under fresh and thermally aged state. This methodology involves the determination of filter physical (flow resistance under clean and soot loaded conditions and filtration efficiency) and chemical properties (reactivity of catalytic coating towards direct soot oxidation). Thermal aging led to sintering of catalytic nanoparticles and to changes in the structure of the catalytic layer affecting negatively the filter wall permeability, the clean filtration efficiency and the pressure drop behavior during soot loading. It also affected negatively the catalytic soot oxidation activity of the catalyzed samples.
Journal Article

Analysis of Asymmetric and Variable Cell Geometry Wall-Flow Particulate Filters

2014-04-01
2014-01-1510
Asymmetric and Variable Cell (AVC) geometry Diesel Particulate Filters (DPF) occupy an increasing portion of the DPFs currently offered by various DPF manufacturers, aiming at providing higher filtration area in the same filter volume to meet demanding emission control applications for passenger cars but also for heavy duty vehicles. In the present work we present an approach for designing and optimizing such DPFs by providing a quantitative description of the flow and deposition of soot in these structures. Soot deposit growth dynamics in AVC DPFs is studied computationally, primary and secondary flows over the inlet channels cross-sectional perimeters are analyzed and their interactions are elucidated. The result is a rational description of the observed growth of soot deposits, as the flow readjusts to transport the soot particles along the path of least resistance (which is not necessarily the shortest geometric path between the inlet and outlet channel, i.e. the wall thickness).
Technical Paper

Further Experimental Study of Asymmetric Plugging Layout on DPFs: Effect of Wall Thickness on Pressure Drop and Soot Oxidation

2015-04-14
2015-01-1016
In order to guide the development of asymmetric plugging layout Diesel Particulate Filters, hereafter referred to as “VPL-DPF”, in this paper we present some evaluation results regarding the effect of design parameters on the VPL-DPF performance. VPL-DPF samples which have different wall thicknesses (thin and thick walls) were evaluated in regards to their pressure drop and soot oxidation behaviors, with the aim to optimize the design of DPF structure. As a result of pressure drop evolution during soot loading, contrary to our expectation, in some cases, it was found out that VPL increases the transient pressure drop compared to the conventional plugging layout DPF. That meant there is an appropriate specific optimum wall thickness for adoption of VPL which has to be well defined at its structural design phase. Based on our previous research, it is expected that this result is due to interactions among the different (five) wall flows that exist in a VPL-DPF.
Technical Paper

New Asymmetric Plugging Layout of Diesel Particulate Filters for the Pressure Drop Reduction

2014-04-01
2014-01-1512
Diesel particulate filters (DPFs) equipped with diesel vehicles have become indispensable components to capture the soot emitted from the engines from a viewpoint of both human health and global warming problems as well as the prevailing regulations. Meanwhile, the pressure drop caused by them leads to a direct increase of fuel consumption. In order to reduce it guaranteeing the sufficient soot filtration efficiency, we have developed the new concept of asymmetric plugging layout for the DPF design, so-called Valuable Plugging Layout (VPL), on the basis of octosquare (OS) structure and have clarified the advantage of the pressure drop reduction both experimentally and theoretically. The VPL-DPF consists of two kinds of octagonal/square inlet channels and octagonal outlet channels, and there are thought to be five filtration velocity modes as well as four kinds of soot deposit layers on each side of the inlet channel walls.