A Study of Active and Passive Regeneration Using Laboratory Generated Soot on a Variety of SiC Diesel Particulate Filter Formulations

2010-04-12
2010-01-0533
In this study an attempt to understand and demonstrate the effects of various washcoat technologies under active and passive regeneration conditions was performed. Six different formulations, on 1.0" D. x 3.0" L. SiC wall flow filters at the laboratory level were used at various test conditions, including variable NO₂/NO ratios and O₂ concentrations. Samples were regenerated using active and passive conditions to evaluate regeneration rates and the potential impact of regeneration at the vehicle level. Results were applied to vehicle operating conditions to determine passive functionality and potential benefits. Active regenerations at 2% O₂ and 5% O₂ showed no significant difference in time to complete regeneration and soot burn rates. Active regenerations performed at 1% O₂ and 5% O₂ concentration showed that the regeneration temperature was shifted by approximately 50°C.
Technical Paper

Engine Oil Viscosity Sensors Using Disks of PZT Ceramic as Electromechanical Vibrators

1997-05-01
971702
Experimental forms of two different types of engine oil viscosity sensors have been tested that use uniformly poled disks of piezoelectric PZT ceramic. In both cases, the disks were used to form electromechanical resonators functioning as the frequency-controlling element in a transistor oscillator circuit. The simpler type of sensor used only one disk, vibrating in a radial-longitudinal mode of vibration. In this mode, a disk 2.54 cm in diameter and 0.127 cm thick had a resonant frequency of approximately 90 kHz. The second type of sensor used two such disks bonded together by a conducting epoxy, with poling directions oriented in opposite directions. This composite resonator vibrated in a radially-symmetrical, flexural mode of vibration, with the lowest resonant frequency at approximately 20 kHz. The presence of tangential components of motion on the major faces of both resonators made them sensitive to the viscosity of fluids in which they were immersed.
Technical Paper

Exhaust Gas Temperature Determination with HEGO Parameters

2010-04-12
2010-01-1303
Exhaust gas temperature is often measured with a device such as thermocouple or RTD (Resistance Temperature Detector). An alternative method to determine the gas temperature would be to use an existing gas sensor heating mechanism to perform as a temperature sensor. A planar type FLOH (Fast Light Off HEGO-Heated Exhausted Gas Oxygen) sensor under transient vehicle speed/load conditions is suited to this function and was modeled to predict the exhaust gas temperature. The numerical input to the model includes exhaust flow rate, heater voltage, and heater current. Laboratory experiments have been performed to produce an equation relating the resistance of the heater and the temperature of the sensor (heater), which provides a method to indirectly determine HEGO sensor temperature.
Technical Paper

Deactivation of Cu/Zeolite SCR Catalyst under Lean-Rich Aging Conditions

2010-04-12
2010-01-1180
A lean-rich hydrothermal aging was used to study the deactivation of Cu-zeolite SCR catalyst that has enhanced stability. Impact of DOC upstream on the SCR catalyst during the lean-rich aging was also investigated. The LR hydrothermal aging was conducted with the presence of hydrocarbon, CO and H₂ at different O₂ levels. It was found that the SCR catalyst was active for the oxidation of CO, H₂ and hydrocarbon, resulting in significant exotherm across the catalyst. In addition to hydrothermal aging, reductive aging, especially the presence of H₂ in the aging gas stream without O₂ presence during the L-R aging, might also contribute to the Cu/zeolite SCR catalyst deactivation. The impacts of DOC upstream on Cu/zeolite SCR catalysts depended on the aging temperatures. At lower aging temperature, the uncompleted oxidation of hydrocarbon and CO on the DOC might cause steam reforming and water-gas shift reactions on the DOC to form reductive gas stream.
Technical Paper

Modeling the Effect of Substrate Cell Shape on Conversion in Monolith Catalysts

2001-03-05
2001-01-0932
Mass transfer limitations from the bulk gas phase to the surface of the catalyst as well as mass transfer limitations within the washcoat itself have important effects on conversion in washcoated monolith catalysts. These factors depend upon the shape of the channel as well as the loading of washcoat material. This paper outlines a method to describe the washcoat distribution profile for different channel shapes and washcoat loadings. This allows for prediction of effectiveness factors and bulk mass transfer coefficients as a function of cell geometry and washcoat loading for the oxidation of propane. It was found that differences in the diffusion limitations within the washcoat control conversion in the catalyst more than differences in bulk mass transfer rates when comparing different cell shapes. The results show that optimum washcoat loadings exist for the geometry of each cell, and that these optimum loadings are a function of catalyst temperature.
Technical Paper

Laboratory Assessment of the Oxidation and Wear Performance Capabilities of Low Phosphorus Engine Oils

2001-09-24
2001-01-3541
Meeting upcoming stringent emission standards will require that exhaust gas catalyst systems become active very quickly, function at very high efficiencies and maintain those capabilities at high mileages. This means that contamination of the catalysts by engine oil derived poisons must be minimized. Phosphorus compounds, derived from the zinc dialkyldithio-phosphate (ZDTP) additives that provide antiwear and antioxidant activity, are a principal contaminant that can increase catalyst light off times and reduce catalyst efficiency. Therefore, reducing the concentration of, or eliminating, phosphorus in engine oils is desirable. Doing so, however, requires that oils be reformulated to ensure that wear protection will not be compromised and that oxidation stability will be maintained. To address these concerns, laboratory tests for evaluating oil oxidation and wear performance have been developed and used to evaluate developmental low phosphorus oils.
Technical Paper

Improved Low-Emission Vehicle Simulator for Evaluation of Sampling and Analytical Systems

2002-03-04
2002-01-0049
The Vehicle Exhaust Emissions Simulator was developed to evaluate the performance of vehicle emissions sampling and analytical systems. The simulator produces a representative tailpipe volume flow rate containing up to five emission constituents, injected via mass flow controllers (MFCs). Eliminating the variability of test results associated with the vehicle, driver, and dynamometer makes the simulator an ideal quality control tool for use in commissioning new test cells, checking data correlation between test cells, and evaluating overall system performance. Earlier vehicle emissions simulators being used in the industry were primarily for checking Constant Volume Samplers (CVSs) and Bag Benches but they did not have the ability to properly simulate tailpipe volume.
Technical Paper

Ultra Thin Wall Substrates - Trends for Performance in FTP and US06 Tests

2002-03-04
2002-01-0356
This paper compares the emissions performance of four ultra thin wall ceramic substrates with standard wall thickness product on a chassis dynamometer for two different substrate volumes. This comparison helps establish performance trends and provides useful information for selection of substrates in designing catalytic converter systems. This experimental study tests and compares four ultra thin wall products (400/4, 600/3, 600/4, and 900/2) with a standard wall product (400/6.5) at two different substrate volumes. Engine bench aging is used to simulate typical aged conditions. Temperature data as well as second by second and bag emissions data for hydrocarbons, carbon monoxide and oxides of nitrogen were used to evaluate the relative performances of the substrates. The US FTP and US06 driving cycles were used as protocols for the comparison. Results suggest that lower bulk density and higher geometric surface area interact to lead to lower emissions.
Technical Paper

Running Loss Test Procedure Development

1992-02-01
920322
A running loss test procedure has been developed which integrates a point-source collection method to measure fuel evaporative running loss from vehicles during their operation on the chassis dynamometer. The point-source method is part of a complete running loss test procedure which employs the combination of site-specific collection devices on the vehicle, and a sampling pump with sampling lines. Fugitive fuel vapor is drawn into these collectors which have been matched to characteristics of the vehicle and the test cell. The composite vapor sample is routed to a collection bag through an adaptation of the ordinary constant volume dilution system typically used for vehicle exhaust gas sampling. Analysis of the contents of such bags provides an accurate measure of the mass and species of running loss collected during each of three LA-4* driving cycles. Other running loss sampling methods were considered by the Auto-Oil Air Quality Improvement Research Program (AQIRP or Program).
Technical Paper

Innovative Robust Solutions for Lean Manufacturing in Automotive Assembly Processes

2011-04-12
2011-01-1254
The article presents an innovative approach to the implementation of a robust design optimization solution in an automobiles assembly process. The approach of the entire project is specific to the 6 Sigma optimization process, by applying the DMAIC cycle integrated in a robust engineering approach for rendering lean the final product assembly process. According to the improvement cycle, the aspects specific for such a process are presented sequentially starting with the “Define” phase for presenting the encountered problem and continuing with the presentation of the scope of the project and its objectives. The “Improvement” cycle phase is applied by the analysis of the monitored 6 Sigma metrics (defined during the previous “Measure” phase and the cause and effect analysis, done during a brainstorming meeting developed during the “Analyze” phase). There follows a proposal for the innovative robust solution by which the assembly process is optimized.
Technical Paper

Static Characteristics of ZrO2 Exhaust Gas Oxygen Sensors

1993-03-01
930352
Results of laboratory studies of the static characteristics of several different commercially available heated exhaust gas oxygen sensors are described. In these studies, the emf of the sensors was measured as a function of temperature and of the composition of calibrated gas mixtures. Several different binary gas mixtures (H2/N2, CO/N2, C3H6/N2, C3H8/N2, and CH4/N2) were used together with a variable amount of O2. In addition to laboratory studies, the same sensors were also studied in the exhaust gas of an engine. Whereas at high temperatures thermodynamic equilibrium appears to prevail, clear departures from thermodynamic equilibrium are observed at some lower temperatures (the value of which depends on the specific sensor and the specific gas mixture used). This behavior is manifested by shifts of the emf step away from stoichiometry, broadening of the step, abnormally high emf values in excess oxygen mixtures, and abnormally low emf values in reducing gas mixtures.
Technical Paper

A Sampling System for the Measurement of PreCatalyst Emissions from Vehicles Operating Under Transient Conditions

1993-03-01
930141
A proportional sampler for vehicle feedgas and tailpipe emissions has been developed that extracts a small, constant fraction of the total exhaust flow during rapid transient changes in engine speed. Heated sampling lines are used to extract samples either before or after the catalytic converter. Instantaneous exhaust mass flow is measured by subtracting the CVS dilution air volume from the total CVS volume. This parameter is used to maintain a constant dilution ratio and proportional sample. The exhaust sample is diluted with high-purity air or nitrogen and is delivered into Tedlar sample bags. These transient test cycle weighted feedgas samples can be collected for subsequent analysis of hydrocarbons and oxygenated hydrocarbon species. This “mini-diluter” offers significant advantages over the conventional CVS system. The concentration of the samples are higher than those collected from the current CVS system because the dilution ratio can be optimized depending on the fuel.
Technical Paper

Organizing the Engineer's Toolbox

1993-03-01
930836
QFD, FMEA, Process Improvement, Taguchi, Simultaneous Engineering, PDP, Project Management, DVP, DOE, …and the list goes on. Today's automotive product design engineers face a myriad of “tools” (methodologies, techniques, procedures) that are expected to be mastered and used in the course of performing their job. The list continually grows with new tools being added to the existing ones. And each new tool has an associated acronym to add to the confusion. New and inexperienced engineers are often confused by these tools being tossed at them …school did not cover all this ! The experienced engineer is often skeptical. After all, “if I have been a successful engineer for 20 years, why do I need to start doing these things now?” Nevertheless, most of these tools are truly needed by engineers today in order to be competitive in the increasingly complex and sophisticated world of automotive product design.
Technical Paper

Improvements in Heater, Defroster and Emissions Performances Using a Latent Heat Storage Device

1994-02-01
940089
Here we present a latent heat storage device which is used to provide “quick/supplemental” heat to the vehicle's conventional heating system. First, we present data from actual in-vehicle cold weather tests. Data are presented for heater and defroster performance tests, emissions tests and cold start tests after extended soaks. Secondly, heater performance predictions are made using a computer simulation program. Finally, the actual heater performance results are compared with the computer simulation.
Technical Paper

Analytical and Experimental Evaluation of a Thermally Insulated Automotive Exhaust System

1994-03-01
940312
For an automotive exhaust system, analytical evaluation of coatings, dual wall, multiwall, and blanket insulation methods indicated that the blanket insulation provided the best method for heat containment. An experimental vehicle was tested with and without a blanket insulation on the exhaust system over a demanding heat protection cycle. The exhaust gas, pipe wall, surrounding air, and adjacent component temperatures at 25 locations along the pipe are reported indicating reduced outer wall temperatures and good containment of the heat. A comparison of the heat lost through the exhaust system walls is presented.
Technical Paper

Gasoline Burner for Rapid Catalyst Light-off

1994-10-01
942072
This paper describes a study which was carried out to assess the potential for using a gasoline burner to heat the catalytic convertor during cold start. The results showed the catalyst/burner concept to be a promising LEV/ULEV capable technology. On a 1993 Ford Grand Marquis equipped with a catalyst burner system, catalyst light-off was achieved in less than 15 seconds while cold start HC emissions during the first 60 seconds of the FTP test were reduced by 60%. In addition, data are presented which compare the performance of the catalyst/burner to an electrically heated catalyst. In the tests performed, the catalyst/burner system out performed the EHC. Practical considerations, however, such as safety, durability, system integration, and packaging still need to be addressed.
Technical Paper

A Non-Intrusive Method of Measuring PCV Blowby Constituents

1994-10-01
941947
A technique is presented that has been successfully demonstrated to non-intrusively and quickly sample gases typically found in PCV systems. Color Detection Tubes (CDTs) were used with a simple sampling arrangement to monitor CO2, NOx, O2, and H2O(g) at the closure line, crankcase, and PCV line. Measurements were accurate and could be made instantaneously. Short Path Thermal Desorbtion Tubes (SPTDTs) were used at the same engine locations for the characterization of fuel- and oil-derived hydrocarbon (HC) fractions and required only 50 cc samples. High engine loads caused pushover of blowby vapors as indicated by increased concentrations of CO2, NOx, H2O(g), and fuel HCs in the engines' fresh air inlets during WOT operation. Peak concentrations of blowby vapors were measured in the crankcase under no load and part throttle conditions. Oxygen concentrations always opposed the trends of CO2, NOx, and H2O(g).
Technical Paper

Measurements of Total and Speciated Hydrocarbon Removal from Engine Exhaust Using Activated Carbon

1994-10-01
941999
A hydrocarbon trapping system for cold start emissions was constructed and tested using two types of carbonaceous adsorbents provided by Corning, Inc. One was made by combining activated carbon with an organic binder and extruding it into a honeycomb, and the other by depositing a carbon coating on a ceramic monolith. The tests were carried out on an engine in a dynamometer laboratory to characterize the performance of the carbon elements under transient cold start conditions. Performance was evaluated by continuously measuring exhaust gas hydrocarbon concentrations upstream and downstream of the trap, using conventional emissions consoles. Samples were also collected for off-line analysis of individual hydrocarbon species using gas chromatography to examine differences in adsorption of individual species. The speciated hydrocarbon data were used to distinguish between the mass trapping efficiency and a reactivity-based trapping efficiency of the adsorbant traps.
Technical Paper

Cavitation Thresholds of Engine Oils as Functions of Temperature and Frequency

1994-10-01
941984
Cavitation thresholds of 5W30 and 10W30 oils were measured in laboratory experiments using electrically-driven disks of piezoelectric ceramic as sources of mechanical excitation. The technique allows the mechanical-wave power density at which cavitation begins to be observed and calculated from electrical quantities and the volume of the oil sample being tested. Both cavitation turn-on and turn-off thresholds have been measured as functions of temperature and frequency. The temperatures ranged from 20 to 100°C and the frequencies ranged from 50 kHz to 4 MHz. The experiments have shown these oils can be made to undergo cavitation at surprisingly low thresholds.
Technical Paper

Variability in Hydrocarbon Speciation Measurements at Low Emission (ULEV) Levels

1995-02-01
950781
As vehicle tailpipe emission levels decrease with improvements in emission control technology and reformulation of gasolines, exhaust hydrocarbon levels begin to approach the levels in ambient air. Hydrocarbon speciation at these low levels requires high sensitivity capillary gas chromatography methods. In this study, a mixture of “synthetic” exhaust was prepared at two concentration levels (approximately 5 ppm C and 10 ppm C), and was analyzed by the widely-used Auto/Oil Air Quality Improvement Research Program (AQIRP) Phase II (gas chromatography) speciation method with a sensitivity of 0.005 ppm C for individual species. The mixture at each concentration level, along with a sample of ambient air, was analyzed a total of 20 times on 10 separate days over a 2½ week period. Concentrations of total hydrocarbons (HCs) and individual species (using the AQIRP library) were measured; averages and standard deviations were calculated.