Refine Your Search

Search Results

Viewing 1 to 2 of 2
Technical Paper

Space Station Condensing Heat Exchanger Biofilm Formation and Control Evaluation

1992-07-01
921383
The Space Station Temperature and Humidity Control Condensing Heat Exchangers will be utilized to remove and collect atmospheric water vapor generated by the metabolic and hygienic activity of crew members. The porous hydrophilic coating within the heat exchangers will be continually moist and in contact with a steady flow of cabin air which makes them susceptible to microbial growth. This paper summarizes the findings from an ongoing study to evaluate biofilm formation characteristics and microbial control techniques for the Space Station Condensing Heat Exchangers (CHX). This ongoing study examines whether the CHX's are susceptible to performance degrading microbial colonization with microbial challenge testing under simulated system environmental conditions. Furthermore, the three candidate microbial control approaches of periodic heating, periodic drying and incorporation of an antimicrobial agent, into the hydrophilic coating are evaluated.
Technical Paper

Condensing Heat Exchanger Microbial Growth and Control Study-Phase II

1993-07-01
932107
The Space Station Temperature and Humidity Control Condensing Heat Exchangers will be utilized to collect and remove atmospheric water vapor generated by the metabolic and hygienic activity of crew members. The porous hydrophilic coating within the heat exchangers will always be wet. Cabin air will continuously flow through the heat exchangers during system operation which makes them a potential site for microbial colonization. This paper summarizes the findings from an ongoing study which evaluates biofilm formation on wet hydrophilic coated panels compared to panels to which microbial control measures have been applied. The control measures evaluated are an antimicrobial agent within the coating and periodic drying.
X