Refine Your Search

Topic

Search Results

Viewing 1 to 17 of 17
Technical Paper

Pedestrian Orientation Estimation Using CNN and Depth Camera

2020-04-14
2020-01-0700
This work presents a method for estimating human body orientation using a combination of convolutional neural network (CNN) and stereo camera in real time. The approach uses the CNN model to predict certain human body keypoints then transforms these points into a 3D space using the stereo vision system to estimate the body orientations. The CNN module is trained to estimate the shoulders, the neck and the nose positions, detecting of three points is required to confirm human detection and provided enough data to translate the points into 3D space.
Journal Article

Scuffing Test Rig for Piston Wrist Pin and Pin Bore

2015-04-14
2015-01-0680
In practice, the piston wrist pin is either fixed to the connecting rod or floats between the connecting rod and the piston. The tribological behavior of fixed wrist pins have been studied by several researchers, however there have been few studies done on the floating wrist pin. A new bench rig has been designed and constructed to investigate the tribological behavior between floating pins and pin bore bearings. The experiments were run using both fixed pins and floating pins under the same working conditions. It was found that for fixed pins there was severe damage on the pin bore in a very short time (5 minutes) and material transfer occurs between the wrist pin and pin bore; however, for the floating pin, even after a long testing time (60 minutes) there was minimal surface damage on either the pin bore or wrist pin.
Technical Paper

Analysis of a Frontal Impact of a Formula SAE Vehicle

2006-12-05
2006-01-3627
The objective of this study was to determine risk of injury to the driver during a frontal impact in a Formula SAE vehicle. Formula SAE is a collegiate student design competition where every year universities worldwide build and compete with open-wheel formula-style race cars. Formula SAE 2006 rules stipulate the use of an impact attenuator to absorb energy in the event of a frontal impact. These rules mandated an average deceleration not to exceed 20-g from a speed of 7.0 m/s (23 ft/s), but do not specify a specific time or pulse shape of the deceleration. The pulse shapes tested in this study included an early high-g, constant-g, and late high-g pulse. The tests were performed using the deceleration sled at the Kettering University Crash Safety Center. Using industry standard practices, this study examined the driver's risk of injury with regard to neck and femur loads, head and chest accelerations, as well as kinematic analysis using high speed video.
Technical Paper

External Knee Geometry Surface Variation as a Function of Subject Anthropometry and Flexion Angle for Human and Surrogate Subjects

2007-04-16
2007-01-1162
The current study was designed to compare the surface anatomy of the knee for different human subject anthropometries using a 3-D, non-contact digitizer which converted the anatomy into point clouds. The subjects were studied at flexion angles of 60, 90, and 120 degrees. Multiple subjects fitting narrow anthropometrical specifications were studied: 5th percentile female, 50th percentile male, and 95th percentile male. These data were then compared to a corresponding anthropometrical crash dummy knee which served as an unambiguous control. Intersubject human comparisons showed surface geometry variations which were an order of magnitude smaller than comparisons between the human and dummy knee. Large errors between the human and dummy were associated with the muscle bulk proximal and distal to the popliteal region and the rounder shape of the human knee.
Technical Paper

Effect of Head and Neck Anthropometry on the Normal Range of Motion of the Cervical Spine of Prepubescent Children

2009-06-09
2009-01-2302
Application of cervical spine range of motion data and related anthropometric measures of the head and neck include physical therapy, product design, and computational modeling. This study utilized the Cervical Range of Motion device (CROM) to define the normal range of motion of the cervical spine for subjects five (5) through ten (10) years of age. And, the data was collected and analyzed with respect to anatomical measures such as head circumference, face height, neck length, and neck circumference. This study correlates these static anthropometric measures to the kinematic measurement of head flexion, extension, lateral extension, and rotation.
Technical Paper

Analysis of Rollover Injuries for 125 Occupants at a Single Trauma Center With Special Focus on Head and Neck Injury

2004-03-08
2004-01-0321
Analysis of the National Automotive Sampling System (NASS) data reveals that vehicle rollover accidents account for a relatively a small number of accidents, but the associated frequency of serious injury is high compared to frontal or side impact. These data demonstrate the apparently elevated probability of head and neck injury during rollover, with head injury occurring more frequently, injured 4.5 times more frequently than the neck when considering all injuries. Automotive industry researchers have performed numerous rollover tests with instrumented ATD's and have predicted an elevated probability of neck injury with little chance of head injury. This contradicts field data (NASS-CDS) which suggests a high frequency of head injury with little chance of neck injury. This difference may be explained in part, through the different volumes of data presented in the literature.
Technical Paper

Considerations for Rollover Simulation

2004-03-08
2004-01-0328
Rollover crashes are responsible for a significant proportion of traffic fatalities each year, while they represent a relatively small proportion of all motor vehicle collisions. The purpose of this study was to focus on rollover events from an occupant's perspective to understand what type of industry test method, ATD, computer based model, and injury assessment measures are required to provide occupant protection during rollovers. Specific injuries most commonly experienced in rollovers along with the associated injury sources were obtained by review of 1998-2000 NASS-CDS records. These data suggest that models capable of predicting the likelihood of brain injuries, specifically subarachnoid and subdural hemorrhage, are desirable. Ideally, the model should also be capable of predicting the likelihood of rib fractures, lung contusions and shoulder (clavicular and scapular) fractures, and facet, pedicle, and vertebral body fractures in the cervical spine.
Technical Paper

High Speed Measurement of Contact Pressure and Area during Knee-to-Instrument Panel Impact Events Suffered from Frontal Crashes

2001-03-05
2001-01-0174
Numerous human cadaver impact studies have shown that acute injury to the knee, femoral shaft, and hip may be significantly reduced by increasing the contact area over the anterior surface of the knee. Such impact events are common in frontal crashes when the knee strikes the instrument panel (IP). The cadaveric studies show that the injury threshold of the knee-thigh-hip complex increases as the contact area over the knee is likewise increased. Unfortunately, no prior methodology exists to record the spatial and temporal contact pressure distributions in dummy (or cadaver) experiments. Previous efforts have been limited to the use of pressure sensitive film, which only yields a cumulative record of contact. These studies assumed that the cumulative pressure sensitive film image correlated with the peak load, although this has never been validated.
Technical Paper

A Rigid Shearographic Endosscopic for Applications

2005-04-11
2005-01-0488
Shearography has been proved to be highly effective for nondestructive testing (NDT), especially for NDT of composite materials used in the automotive and aerospace engineering. While its application in material testing and material research has already achieved more and more acceptance in research and industry, its applications are mainly limited to the inspection and testing of an object surface which can directly be observed by a shearographic camera. Its application is mainly limited to inspect and test an object surface which can directly be observed by a shearographic camera. It is impossible to inspect an internal surface of a container. If the reflected light of the surface, which has to be examined, can’t reach the shearographic camera there is still no inspection possible. This paper presents the development of a rigid shearographic endoscope. The development enabled shearographic inspection on both external and internal surfaces of objects.
Journal Article

Quantum Explanations for Interference Effects in Engineering Decision Making

2022-03-29
2022-01-0215
Engineering practice routinely involves decision making under uncertainty. Much of this decision making entails reconciling multiple pieces of information to form a suitable model of uncertainty. As more information is collected, one expectedly makes better and better decisions. However, conditional probability assessments made by human decision makers, as new information arrives does not always follow expected trends and instead exhibits inconsistencies. Understanding them is necessary for a better modeling of the cognitive processes taking place in their mind, whether it be the designer or the end-user. Doing so can result in better products and product features. Quantum probability has been used in the literature to explain many commonly observed deviations from the classical probability such as: question order effect, response replicability effect, Machina and Ellsberg paradoxes and the effect of positive and negative interference between events.
Technical Paper

Human Body Orientation from 2D Images

2021-04-06
2021-01-0082
This work presents a method to estimate the human body orientation using 2D images from a person view; the challenge comes from the variety of human body poses and appearances. The method utilizes OpenPose neural network as a human pose detector module and depth sensing module. The modules work together to extract the body orientation from 2D stereo images. OpenPose is proven to be efficient in detecting human body joints, defined by COCO dataset, OpenPose can detect the visible body joints without being affected by backgrounds or other challenging factors. Adding the depth data for each point can produce rich information to the process of 3D construction for the detected humans. This 3D point’s setup can tell more about the body orientation and walking direction for example. The depth module used in this work is the ZED camera stereo system which uses CUDA for high performance depth computation.
Technical Paper

Physical Validation Testing of a Smart Tire Prototype for Estimation of Tire Forces

2018-04-03
2018-01-1117
The safety of ground vehicles is a matter of critical importance. Vehicle safety is enhanced with the use of control systems that mitigate the effect of unachievable demands from the driver, especially demands for tire forces that cannot be developed. This paper presents the results of a smart tire prototyping and validation study, which is an investigation of a smart tire system that can be used as part of these mitigation efforts. The smart tire can monitor itself using in-tire sensors and provide information regarding its own tire forces and moments, which can be transmitted to a vehicle control system for improved safety. The smart tire is designed to estimate the three orthogonal tire forces and the tire aligning moment at least once per wheel revolution during all modes of vehicle operation, with high accuracy. The prototype includes two in-tire piezoelectric deformation sensors and a rotary encoder.
Technical Paper

Real Time 2D Pose Estimation for Pedestrian Path Estimation Using GPU Computing

2019-04-02
2019-01-0887
Future fully autonomous and partially autonomous cars equipped with Advanced Driver Assistant Systems (ADAS) should assure safety for the pedestrian. One of the critical tasks is to determine if the pedestrian is crossing the road in the path of the ego-vehicle, in order to issue the required alerts for the driver or even safety breaking action. In this paper, we investigate the use of 2D pose estimators to determine the direction and speed of the pedestrian crossing the road in front of a vehicle. Pose estimation of body parts, such as right eye, left knee, right foot, etc… is used for determining the pedestrian orientation while tracking these key points between frames is used to determine the pedestrian speed. The pedestrian orientation and speed are the two required elements for the basic path estimation.
Technical Paper

Injury Sources for Second Row Occupants in Frontal Crashes Considering Age and Restraint Condition Influence

2015-04-14
2015-01-1451
The current study examined field data in order to document injury rates, injured body regions, and injury sources for persons seated in the second row of passenger vehicles. It was also intended to identify whether these varied with respect to age and restraint use in vehicles manufactured in recent years. Data from the 2007-2012 National Automotive Sampling System (NASS/CDS) was used to describe occupants seated in the second row of vehicles in frontal crashes. Injury plots, comparison of means and logistic regression analysis were used to seek factors associated with increased risk of injury. Restraint use reduced the risk of AIS ≥ 2 injury from approximately 1.8% to 5.8% overall. Seventy nine percent of the occupants in the weighted data set used either a lap and shoulder belt or child restraint system. The most frequently indicated injury source for persons with a MAIS ≥ 2 was “seat, back support”, across restraint conditions and for all but the youngest occupants.
Technical Paper

A Method of Filter Implementation Using Heterogeneous Computing System for Driver Health Monitoring

2021-04-06
2021-01-0103
Research in any field of study requires analysis and comparisons or real-time predictions to extract useful information. To prove that the results have practical potential, various filtering techniques and methodologies should be designed and implemented. Filters being a class of signal processing helps innovate new technologies with various kinds of outcomes, using filters there are always various methods to solve a problem. Considering the current COVID-19 situation, researchers are working on sequencing the novel coronavirus and the genomes of people afflicted with COVID-19 using CPUs and GPUs along with various filtering techniques. In this paper we are using a method of filter implementation to collect raw heart rate data samples from fingertip and ear lobe and process those results on CPUs and GPUs. Our method of implementation to collect raw heart rate data is using a photoplethysmography method.
Journal Article

Preliminary Study of Perceived Vibration Quality for Human Hands

2019-06-05
2019-01-1522
A large body of knowledge exists regarding the effects of vibration on human beings; however, the emphasis is generally on the damaging effects of vibration. Very little information has been published regarding the effect of vibration on perceived consumer product quality. The perceived loudness of a product is quantified using the Fletcher-Munson equal loudness curves, but the equivalent curves for perceived vibration amplitude as a function of amplitude and frequency are not readily available. This “vibration quality” information would be valuable in the design and evaluation of many consumer products, including automobiles. Vibration information is used in the automobile design process where targets for steering wheel, seat track, and pedal vibration are common. For this purpose, the vibration information is considered proprietary and is generally applicable to a narrow frequency range. In this investigation, work paralleling the original Fletcher-Munson study is presented.
Technical Paper

A Methodology for Measurement and Analysis of Head-To- B-Pillar Contact Pressure and Area Response

2001-03-05
2001-01-0718
Government accident statistics show that approximately 35% of all car accident victims suffer an injury to the head and face. Such injuries are common during frontal, side, and rollover accidents as the head may impact the steering wheel, side pillars, windshield, or roof. Further, non-threatening injuries (i.e abrasions) may be suffered due to contact with the deployed airbag, or, in the case of an out-of-position occupant, a deploying airbag. While the forces and accelerations measured internal to the head are known to correlate with serious head injury (i.e. concussion, skull fracture, diffuse axonal injury), it is currently not possible to record how the loads are distributed over the head and face with the current ATD. Ultimately, such data could eventually be used to provide improved resolution as to the probability of superficial, soft tissue damage since past cadaver studies show that the distribution of contact pressures are related to such injuries.
X