Refine Your Search

Search Results

Viewing 1 to 9 of 9
Technical Paper

A System for Neutralizing Static Electricity on the Human Body in a Vehicle

2008-04-14
2008-01-0786
People often feel discomfort when entering or exiting a vehicle because of a static electric shock. In the electronics industry, ionizers have been developed to prevent electrostatic discharges and contamination sticking around or on circuit components. Ionizers incorporate corona discharge principles to neutralize the static electric field. Using this idea, we developed an in-vehicle system to neutralize the human body charge. To accomplish this, the mechanism by which the human body attains a charge when exiting a vehicle was first defined. That definition was then used to determine the design characteristics of the system.
Technical Paper

Analysis of Interior Airflow in a Full-Scale Passenger-Compartment Model Using a Laser-Light-Sheet Method

1992-02-01
920206
Flow velocity distributions in the passenger compartment were measured from visualized images of particle flow paths obtained with a full-scale model. The flow paths were visualized using an approach that combined a particle tracing method with a pulse-laser light technique. Air was used as the fluid medium with the full-scale passenger compartment model and water was used as the fluid medium with a one-fourth scale model. A comparison of the results obtained with the two models confirmed that there was good agreement between the flow velocity distributions. Using the full-scale model, measurements were also made of the flow velocity distributions when two dummies were placed in the front-seats.
Technical Paper

Airflow Measurement Around Passenger Car Models Using a Two-Channel Laser Doppler Velocimeter

1993-03-01
930297
A two-channel LDV system is used to obtain accurate airflow measurements around scale models of passenger cars in wind tunnel tests at the Nissan Research Center. A 2-watt argon-ion laser is employed as the light source. The main optical unit and probe head are connected by optical fibers. The probe head consists of a compact LDV probe with a beam expander and focusing lens with a long focal length can be easily traversed. A new type of signal processor, performing a digital autocorrelation function, is employed to process the Doppler signals. Mean airflow velocities and turbulence intensities are calculated by a micro computer to evaluate the flow fields. The results of preliminary experiments conducted with this system indicate that the system is not only capable of measuring the mean velocity components, including reverse flow, it can also provide accurate estimation of turbulence components.
Technical Paper

Measurement of Wake Flow Fields, Including Reverse Flow, of Scale Vehicle Models Using a New 13-Hole Pitot Tube

1996-02-01
960676
Among the various methods for measuring flow velocity vectors, multi-holed pitot tubes offer the advantages of facilitating pressure measurements, low cost and ease of use. On the negative side, the range of measurable flow angles is limited (e.g., to ± 40° with 5-hole tubes) and pitot tubes require time-consuming calibration before use. The authors have developed a new pitot tube with a spherical head and 13 holes arranged such that the pitot head shows a 5-hole pattern when viewed from different right angles. This hole arrangement is equivalent to having several multi-holed pitot tubes connected to one pitot head and expands the measurable range of flow angles substantially to ± 135°. In addition, a robot is used to achieve fully automatic calibration. These two improvements overcome the traditional drawbacks of multi-holed pitot tubes.
Technical Paper

Development of an Engine Oil Temperature Prediction Method Using 3D Model Simulation

2005-04-11
2005-01-1881
Being able to plan each powertrain performance parameter with improved accuracy is an important factor for shortening the development period. In this regard, advance temperature predictions are particularly important because of the strong correlation between the thermal design and the vehicle layout, engine proper and other related parts. At present, it is still difficult to make thermal performance predictions for the engine oil temperature. There are many examples of studies in which the oil temperature was predicted in a one-dimensional circuit. In those studies, either experimental data were used for the heat release from engine components to the oil or calculations were made with a model that was converted empirically from three-dimensions to one-dimension. Because the mechanisms of oil temperature changes inside the engine are not well understood in detail, it is not possible to examine how modifications of the engine structure might affect the oil temperature.
Technical Paper

Evaluation of Equivalent Temperature Using Thermal Factors : Validation of a Calculation Method Based on ISO 14505-4:2021 in a Vehicle Cabin

2022-03-29
2022-01-0190
This paper describes a method for evaluating the equivalent temperature in vehicle cabins based on the new international standard ISO 14505-4, published in 2021. ISO 14505-4 defines two simulation methods to determine a thermal comfort index “equivalent temperature.” One method uses a numerical thermal manikin, and the other uses thermal factors to calculate. This study discusses the latter method to validate its accuracy, identify the key points to consider, and examine its advantages and disadvantages. First, the definition of equivalent temperature and the equation to calculate the equivalent temperature using thermal factors, such as air temperature, radiant temperature, solar radiation, and air velocity, are explained. In addition, the experiments and simulation methods are described.
Technical Paper

Unsteady Pressure Analysis of the Wake Flow Behind a Passenger Car Model

1999-03-01
1999-01-0810
This paper describes a system for measuring unsteady pressure at up to 256 spatial points and at frequencies up to 300 Hz. The system consists of commercially available equipment for measuring steady pressures. It is based on the use of electronically scanned pressure (ESP) sensors, 16 A/D converters, and a personal computer to control the whole system and acquire data. The signal outputs through the tubes connecting the pressure taps and the ESP sensors are compensated, as are the phase delays between the scanned signals and the gain variation. A 1/5 scale model of a sedan was used in this experiment. The passenger car model was placed in a wind tunnel equipped with a moving belt, which was operated at the same speed as the uniform flow in the wind tunnel. Pressure measurements were obtained at 252 points in a plane behind the model perpendicular to the uniform flow. Measurements were made with the belt turned on and off.
Technical Paper

Quantification of Intake System Noise Using an Experimental Source-Transfer-Receiver Model

1999-05-17
1999-01-1659
Design optimisation with respect to interior noise is currently a topic of great concern for the automotive industry. An essential element in this process is to obtain a correct understanding of the various noise sources which are present, and the ways in which these sources propagate to the critical receiver. An experimental source-transfer-receiver methodology is presented, that allows quantifying the structure borne and airborne source strength of the intake system components and its contribution to the interior noise. The method allows interior noise optimisation after identification of the dominant contributors. The methodology is applied to identify the noise contribution of the air intake system to the interior noise of an 8-cylinder upper class vehicle. Correlation of the Structure Borne Transfer Path Analysis and Airborne Source Quantification models with physical decoupling experiments demonstrates a high correspondence.
Technical Paper

Evaluation of Equivalent Temperature in a Vehicle Cabin with a Numerical Thermal Manikin (Part 1): Measurement of Equivalent Temperature in a Vehicle Cabin and Development of a Numerical Thermal Manikin

2019-04-02
2019-01-0697
The present paper is Part 1 of two consecutive studies. Part 1 describes three subjects: definition of the equivalent temperature (teq), measurements of teq using a clothed thermal manikin in a vehicle cabin, and modeling of the clothed thermal manikin for teq simulation. After defining teq, a method for measuring teq with a clothed thermal manikin was examined. Two techniques were proposed in this study: the definition of “the total heat transfer coefficient between the skin surface and the environment in a standard environment (hcal)” based on the thermal insulation of clothing (Icl), and a method of measuring Icl in consideration of the area factor (fcl), which indicates the ratio of the clothing surface to the manikin surface area. Then, teq was measured in an actual vehicle cabin by the proposed method under two conditions: a summer cooling condition with solar radiation and a winter heating condition without solar radiation.
X