Refine Your Search

Search Results

Viewing 1 to 7 of 7
Journal Article

Impact of Transient Operating Conditions on Electrical Power System and Component Reliability

2014-09-16
2014-01-2144
Transient operating conditions in electrical systems not only have significant impact on the operating behavior of individual components but indirectly affect system and component reliability and life. Specifically, transient loads can cause additional loss in the electrical conduction path consisting of windings, power electronic devices, distribution wires, etc., particularly when loads introduce high peak vs. average power ratios. The additional loss increases the operating temperatures and thermal cycling in the components, which is known to reduce their life and reliability. Further, mechanical stress caused by dynamic loading, which includes load torque cycling and high peak torque loading, increases material fatigue and thus reduces expected service life, particularly on rotating components (shaft, bearings).
Journal Article

A Hybrid Economy Bleed, Electric Drive Adaptive Power and Thermal Management System for More Electric Aircraft

2010-11-02
2010-01-1786
Minimizing energy use on more electric aircraft (MEA) requires examining in detail the important decision of whether and when to use engine bleed air, ram air, electric, hydraulic, or other sources of power. Further, due to the large variance in mission segments, it is unlikely that a single energy source is the most efficient over an entire mission. Thus, hybrid combinations of sources must be considered. An important system in an advanced MEA is the adaptive power and thermal management system (APTMS), which is designed to provide main engine start, auxiliary and emergency power, and vehicle thermal management including environmental cooling. Additionally, peak and regenerative power management capabilities can be achieved with appropriate control. The APTMS is intended to be adaptive, adjusting its operation in order to serve its function in the most efficient and least costly way to the aircraft as a whole.
Technical Paper

Dynamic Testing of Electromechanical Actuators Using Time-history Data

2010-11-02
2010-01-1748
A commercial electromechanical actuator (EMA) is to be dynamically tested with predetermined stroke and load profiles for transient thermal and electric power behavior to validate a numerical model used for aerospace applications. The EMA will follow the stroke profile representative of a real aircraft mission duty cycle. A hydraulic press will exert a corresponding load profile onto the EMA. Specialized hydraulic load control methods must be employed to meet the accuracy requirements. Two of these methods are closed-loop linearization (CLL) and displacement induced disturbance cancellation (DIDC). These methods are implemented along with an external PID compensator, and run in real-time in a series of system identification experiments to observe controller performance.
Technical Paper

Hardware-in-the-Loop Electric Drive Stand Issues for Jet Engine Simulation

2010-11-02
2010-01-1810
Next generation aircraft will require more electrical power, more thermal cooling, and better versatility. To attain these improvements, technologies will need to be integrated and optimized at a system-level. The complexity of these integrated systems will require considerable analysis. In order to characterize and understand the implications of highly-integrated aircraft systems, the effects of pulsed-power, highly-transient loads, and the technologies that drive system-stability and behavior, an approach will be taken utilizing integrated modeling and simulation with hardware-in-the-loop (HIL). Such experiments can save time and cost and increase the general understanding of electrical and thermal phenomena as it pertains to aircraft systems before completing an integrated ground demonstration. As a first step toward completing an integrated analysis, a dynamometer “drive stand” was characterized to assess its performance.
Technical Paper

Experimental Characterization of Brushless Synchronous Machines for Efficient Model-Base System Engineering

2016-09-20
2016-01-2027
Detailed machine models are, and will continue to be, a critical component of both the design and validation processes for engineering future aircraft, which will undoubtedly continue to push the boundaries for the demand of electric power. This paper presents a survey of experimental testing procedures for typical synchronous machines that are applied to brushless synchronous machines with rotating rectifiers to characterize their operational impedances. The relevance and limitations of these procedures are discussed, which include steady-state drive stand tests, sudden short-circuit transient (SSC) tests, and standstill frequency response (SSFR) tests. Then, results captured in laboratory of the aforementioned tests are presented.
Technical Paper

Steady State Characterization of Arcing in 540 V dc Distribution Systems

2017-09-19
2017-01-2035
As applications in aerospace, transportation and data centers are faced with increased electric power consumption, their dc operating voltages have increased to reduce cable weight and to improve efficiency. Electric arcs in these systems still cause dangerous fault conditions and have garnered more attention in recent years. Arcs can be classified as either low impedance or high impedance arcs and both can cause insulation damage and fires. Low impedance arcs release lots of energy when high voltage becomes nearly shorted to ground. High impedance arcs can occur when two current-carrying electrodes are separated, either by vibration of a loose connection or by cables snapping. The high impedance arc decreases load current due to a higher equivalent load impedance seen by the source. This complicates the differentiation of a high impedance arc fault from normal operation.
Technical Paper

Test Set-up for Electromechanical Actuation Systems for Aircraft Flight Control

2012-10-22
2012-01-2203
An Electromechanical Actuation System (EMAS) are an important component for an all electric Aircraft. EMAS would be lighter and require less system maintenance and operational costs than hydraulic actuators, typically used in aircraft systems. Also, hydraulic actuation systems require a constant power load to maintain hydraulic pressure, whereas EMAS only use power when actuation is needed. The technical challenges facing EMAS for aircraft primary flight control includes jam tolerance, thermal management, wide temperature range, high peak electric power draw, regenerative power, installation volume limit for thin wings, etc. This paper focuses on a laboratory test setup to simulate EMAS flight control environment to test and evaluate three important performance parameters of EMAS; thermal management, transient peak power draw, and regenerative power.
X